25
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Clinical translation of handheld optical coherence tomography: practical considerations and recent advancements

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract.

          Since the inception of optical coherence tomography (OCT), advancements in imaging system design and handheld probes have allowed for numerous advancements in disease diagnostics and characterization of the structural and optical properties of tissue. OCT system developers continue to reduce form factor and cost, while improving imaging performance (speed, resolution, etc.) and flexibility for applicability in a broad range of fields, and nearly every clinical specialty. An extensive array of components to construct customized systems has also become available, with a range of commercial entities that produce high-quality products, from single components to full systems, for clinical and research use. Many advancements in the development of these miniaturized and portable systems can be linked back to a specific challenge in academic research, or a clinical need in medicine or surgery. Handheld OCT systems are discussed and explored for various applications. Handheld systems are discussed in terms of their relative level of portability and form factor, with mention of the supporting technologies and surrounding ecosystem that bolstered their development. Additional insight from our efforts to implement systems in several clinical environments is provided. The trend toward well-designed, efficient, and compact handheld systems paves the way for more widespread adoption of OCT into point-of-care or point-of-procedure applications in both clinical and commercial settings.

          Related collections

          Most cited references186

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          A review of optical coherence tomography angiography (OCTA)

          Optical coherence tomography angiography (OCTA) is a new, non-invasive imaging technique that generates volumetric angiography images in a matter of seconds. This is a nascent technology with a potential wide applicability for retinal vascular disease. At present, level 1 evidence of the technology’s clinical applications doesn’t exist. In this paper, we introduce the technology, review the available English language publications regarding OCTA, and compare it with the current angiographic gold standards, fluorescein angiography (FA) and indocyanine green angiography (ICGA). Finally we summarize its potential application to retinal vascular diseases. OCTA is quick and non-invasive, and provides volumetric data with the clinical capability of specifically localizing and delineating pathology along with the ability to show both structural and blood flow information in tandem. Its current limitations include a relatively small field of view, inability to show leakage, and proclivity for image artifact due to patient movement/blinking. Published studies hint at OCTA’s potential efficacy in the evaluation of common ophthalmologic diseases such age related macular degeneration (AMD), diabetic retinopathy, artery and vein occlusions, and glaucoma. OCTA can detect changes in choroidal blood vessel flow and can elucidate the presence of choroidal neovascularization (CNV) in a variety of conditions but especially in AMD. It provides a highly detailed view of the retinal vasculature, which allows for accurate delineation of the foveal avascular zone (FAZ) in diabetic eyes and detection of subtle microvascular abnormalities in diabetic and vascular occlusive eyes. Optic disc perfusion in glaucomatous eyes is notable as well on OCTA. Further studies are needed to more definitively determine OCTA’s utility in the clinical setting and to establish if this technology may offer a non-invasive option of visualizing the retinal vasculature in detail.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Artifacts in CT: recognition and avoidance.

            Artifacts can seriously degrade the quality of computed tomographic (CT) images, sometimes to the point of making them diagnostically unusable. To optimize image quality, it is necessary to understand why artifacts occur and how they can be prevented or suppressed. CT artifacts originate from a range of sources. Physics-based artifacts result from the physical processes involved in the acquisition of CT data. Patient-based artifacts are caused by such factors as patient movement or the presence of metallic materials in or on the patient. Scanner-based artifacts result from imperfections in scanner function. Helical and multisection technique artifacts are produced by the image reconstruction process. Design features incorporated into modern CT scanners minimize some types of artifacts, and some can be partially corrected by the scanner software. However, in many instances, careful patient positioning and optimum selection of scanning parameters are the most important factors in avoiding CT artifacts. (c) RSNA, 2004.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Adaptive optics scanning laser ophthalmoscopy.

              We present the first scanning laser ophthalmoscope that uses adaptive optics to measure and correct the high order aberrations of the human eye. Adaptive optics increases both lateral and axial resolution, permitting axial sectioning of retinal tissue in vivo. The instrument is used to visualize photoreceptors, nerve fibers and flow of white blood cells in retinal capillaries.
                Bookmark

                Author and article information

                Journal
                J Biomed Opt
                J Biomed Opt
                JBOPFO
                JBO
                Journal of Biomedical Optics
                Society of Photo-Optical Instrumentation Engineers
                1083-3668
                1560-2281
                19 December 2017
                December 2017
                : 22
                : 12
                : 121715
                Affiliations
                [a ]Beckman Institute for Advanced Science and Technology , Urbana, Illinois, United States
                [b ]University of Illinois at Urbana-Champaign , Department of Bioengineering, Urbana, Illinois, United States
                [c ]University of Illinois at Urbana-Champaign , Department of Electrical and Computer Engineering, Urbana, Illinois, United States
                [d ]Carle-Illinois College of Medicine , Urbana, Illinois, United States
                Author notes
                [* ]Address all correspondence to: Stephen A. Boppart, E-mail: Boppart@ 123456illinois.edu
                Article
                JBO-170651SSVR 170651SSVR
                10.1117/1.JBO.22.12.121715
                5735247
                29260539
                dee554cd-518a-480c-8b5d-f8c260fdb9d2
                © The Authors.

                Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.

                History
                : 6 October 2017
                : 4 December 2017
                Page count
                Figures: 29, Tables: 0, References: 216, Pages: 30
                Funding
                Funded by: National Institutes of Health (NIH) http://dx.doi.org/10.13039/100000002
                Award ID: R01 EB013723
                Award ID: R01 CA213149
                Categories
                Special Section on 25 years of OCT
                Paper
                Custom metadata
                Monroy et al.: Clinical translation of handheld optical coherence tomography…

                Biomedical engineering
                optical coherence tomography,handheld,diagnostics,point-of-care,system development,multimodal

                Comments

                Comment on this article