      The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. :

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          <p class="first" id="d9156500e69">Failure of fixation of peritrochanteric fractures that have been treated with a fixed-angle sliding hip-screw device is frequently related to the position of the lag screw in the femoral head. A simple measurement has been developed to describe the position of the screw. This measurement, the tip-apex distance, is the sum of the distance from the tip of the lag screw to the apex of the femoral head on an anteroposterior radiograph and this distance on a lateral radiograph, after controlling for magnification. To determine the value of this measurement in the prediction of so-called cutout of the lag screw, 198 peritrochanteric fractures (193 patients) were studied. The minimum duration of follow-up was three months (average, thirteen months), during which period all of the fractures either healed or had failure of the fixation. Of the nineteen failures that were identified, sixteen were due to the device cutting out of the femoral head. The average tip-apex distance was twenty-four millimeters (range, nine to sixty-three millimeters) for the successfully treated fractures compared with thirty-eight millimeters (range, twenty-eight to forty-eight millimeters) for those in which the screw cut out (p = 0.0001). None of the 120 screws with a tip-apex distance of twenty-five millimeters or less cut out, but there was a very strong statistical relationship between an increasing tip-apex distance and the rate of cutout, regardless of all other variables related to the fracture.(ABSTRACT TRUNCATED AT 250 WORDS) </p>

          Related collections

          Author and article information

          Journal
          The Journal of Bone & Joint Surgery
          The Journal of Bone & Joint Surgery
          Ovid Technologies (Wolters Kluwer Health)
          0021-9355
          1995
          July 1995
          : 77
          : 7
          : 1058-1064
          Article
          10.2106/00004623-199507000-00012
          7608228
          df9b7e85-dbad-4542-baf9-5131fddb7bc7
          © 1995
          History

          Comments

          Comment on this article

          Related Documents Log