6
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Uncertainty quantification of two models of cardiac electromechanics.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Computational models of the heart have reached a maturity level that render them useful for in-silico studies of arrhythmia and other cardiac diseases. However, the translation to the clinic of cardiac simulations critically depends on demonstrating the accuracy, robustness and reliability of the underlying computational models under the presence of uncertainties. In this work, we study for the first time the effect of parameter uncertainty on two state-of-the-art coupled models of excitation-contraction of cardiac tissue. To this end, we perform forward uncertainty propagation and sensitivity analyses to understand how variability in key maximal conductances affect selected quantities of interest, such as the action potential duration (APD90 ), maximum intracellular calcium concentration, cardiac stretch and stress. redOur results suggest a strong linear relationship between selected maximal conductances and quantities of interest for a variability in parameters up to 25%, which justifies the construction of linear response surfaces that are used to compute the empirical probability density functions of all the QOIs under study. For both electromechanical models analyzed, uncertainty in the material parameters associated to the passive mechanical response of cardiac tissue does not affect the duration of action potentials, neither the amplitude of intracellular calcium concentrations. Our results confirm the poor mechanoelectric feedback that classical models of cardiac electromechanics have, even under the presence of parameter uncertainty. This article is protected by copyright. All rights reserved.

          Related collections

          Author and article information

          Journal
          Int J Numer Method Biomed Eng
          International journal for numerical methods in biomedical engineering
          Wiley-Blackwell
          2040-7947
          2040-7939
          May 04 2017
          Affiliations
          [1 ] Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
          [2 ] Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile.
          Article
          10.1002/cnm.2894
          28474497
          e08d431b-a9e9-476c-8401-ec529fbe4025
          History

          Cardiac electromechanics,parameter sensitivity analysis,uncertainty propagation,uncertainty quantification

          Comments

          Comment on this article