      Individualisierung der Diabetestherapie durch Automatisierung der Insulingabe Translated title: Individualization of diabetes treatment by automated insulin delivery

      review-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Insulinpumpen und Glucosesensoren haben sich in Registerdaten als effektiv in der Verbesserung der Diabetestherapie und Reduktion akuter Komplikationen gezeigt. In der pädiatrischen Diabetologie ist die Nutzung mindestens eines technischen Geräts Standard. Durch die Kombination beider Systeme ergibt sich Möglichkeit der automatischen Insulinabgabe („automated insulin delivery“, AID).

          Viele AID-Systeme sind in klinischen Studien getestet und haben sich als sicher und effektiv erwiesen. Die Versorgungsituation in Deutschland erlaubt es derzeit nur, Mitgliedern der gesetzlichen Krankenversicherungen ein bestimmtes System zu verordnen; dieses ist für Kinder, die jünger als 7 Jahre sind, nicht geeignet. Gründe liegen in gesetzlichen Hürden und mangelnder Zertifizierung durch die Hersteller. Die CE-Zertifikate können Probleme bei der Insulinverordnung mit sich bringen. „Open-source“-Systeme sind Varianten, mit denen bestehende Regularien umgangen werden können. Daraus ergeben sich sowohl für Nutzer wie auch für Verordner Risiken.

          Die dauerhafte Nutzung setzt sowohl auf Anwender- als auch auf Behandlerseite die fundierte Kenntnis der Eigenschaften der einzelnen AID-Systeme voraus. Eine vollständige Automatisierung funktioniert noch nicht. Zur Evaluation der AID-Therapie sind die metrischen Daten der Glucosesensoren, die „Zeit im Zielbereich“ und der „Glucose Management Indicator“ anerkannte und geeignete Parameter, da sie eine Beratung auf Basis der reellen Daten aus dem Alltag der Menschen mit Diabetes zulassen.

          Da alle Glucosesensoren über Cloud-basierte Software ausgelesen werden oder die Daten automatisch aus einem telefonverbundenen Empfangsgerät beziehen, ist die ideale technische Grundlage für eine telemedizinische Betreuung geschaffen, die noch der Ausgestaltung bedarf.

          Translated abstract

          Insulin pumps and glucose sensors have been shown to be effective in improving diabetes treatment and reducing acute complications according to data from registries. Therefore, in pediatric diabetology the use of at least one technical device is standard. Both devices can also be combined to form automated insulin delivery (AID) systems.

          Many AID systems have been tested in clinical trials and have proven to be safe and effective. The supply situation in Germany currently only allows one system to be prescribed for people insured by the statutory health insurances. Currently, children younger than 7 years of age cannot be treated with this system. The reasons for this are legal hurdles and lack of certification by the manufacturers. The CE certification can also lead to problems with insulin prescriptions. Open-source systems are non-regulated variants to circumvent existing regulatory conditions. There are risks here for both users and prescribers.

          For permanent use a thorough knowledge of the features of each AID system is necessary for both the user and the practitioner. Complete automation does not yet work. For the evaluation of the AID treatment, the metric data of the glucose sensors, the time in range and the glucose management index are the recognized and suitable parameters, because they allow a consultation based on real data from the daily life of people with diabetes.

          As all glucose sensors are read out via cloud-based software or the data are obtained directly and automatically from a telephone-linked receiver device, this provides the ideal technical basis for telemedical care, which still needs to be configured.

          Related collections

          Most cited references29

          • Record: found
          • Abstract: found
          • Article: not found

          Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range

          Improvements in sensor accuracy, greater convenience and ease of use, and expanding reimbursement have led to growing adoption of continuous glucose monitoring (CGM). However, successful utilization of CGM technology in routine clinical practice remains relatively low. This may be due in part to the lack of clear and agreed-upon glycemic targets that both diabetes teams and people with diabetes can work toward. Although unified recommendations for use of key CGM metrics have been established in three separate peer-reviewed articles, formal adoption by diabetes professional organizations and guidance in the practical application of these metrics in clinical practice have been lacking. In February 2019, the Advanced Technologies & Treatments for Diabetes (ATTD) Congress convened an international panel of physicians, researchers, and individuals with diabetes who are expert in CGM technologies to address this issue. This article summarizes the ATTD consensus recommendations for relevant aspects of CGM data utilization and reporting among the various diabetes populations.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Validation of Time in Range as an Outcome Measure for Diabetes Clinical Trials

              This study evaluated the association of time in range (TIR) of 70-180 mg/dL (3.9-10 mmol/L) with the development or progression of retinopathy and development of microalbuminuria using the Diabetes Control and Complications Trial (DCCT) data set in order to validate the use of TIR as an outcome measure for clinical trials.
                Bookmark

                Author and article information

                Contributors
                Biester@hka.de
                Journal
                Monatsschr Kinderheilkd
                Monatsschr Kinderheilkd
                Monatsschrift Kinderheilkunde
                Springer Medizin (Heidelberg )
                0026-9298
                1433-0474
                13 July 2021
                : 1-8
                Affiliations
                [1 ]AUF DER BULT, Kinder- und Jugendkrankenhaus, Janusz-Korczak-Allee 12, 30173 Hannover, Deutschland
                [2 ]GRID grid.29524.38, ISNI 0000 0004 0571 7705, Pädiatrische Diabetologie, Endokrinologie und Stoffwechselerkrankungen, , UMC – Universitätskinderklinik, ; Ljubljana, Slowenien
                [3 ]GRID grid.107891.6, ISNI 0000 0001 1010 7301, Medzinische Fakultät, Kinderklinik, , Universität Opole, ; Opole, Polen
                [4 ]GRID grid.22937.3d, ISNI 0000 0000 9259 8492, Universitätsklinik für Kinder- und Jugendheilkunde, , Medizinische Universität Wien, ; Wien, Österreich
                [5 ]Kinderendokrinologe und Diabetologe, MEDIAN Kinderklinik „Am Nicolausholz“ Bad Kösen, Naumburg, Deutschland
                [6 ]GRID grid.8954.0, ISNI 0000 0001 0721 6013, Medizinische Fakultät, , Universität Ljubljana, ; Ljubljana, Slowenien
                Author notes
                [Redaktion]

                G. Hansen, Hannover

                Article
                1239
                10.1007/s00112-021-01239-0
                8276231
                34276070
                e0f42cb1-e508-4042-811a-00b075c2b597
                © Springer Medizin Verlag GmbH, ein Teil von Springer Nature 2021

                This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.

                History
                : 9 June 2021
                Categories
                Leitthema

                insulinpumpe,glucosesensor,insulininfusionssysteme,zeit im zielbereich,telemedizin,insulin pump,glucose sensor,insulin infusion systems,time in range,telemedicine

                Comments

                Comment on this article