      Desplazamiento de catéteres venosos de punción ecodirigida. Estudio transversal sobre la influencia de la estrategia eFIX para la selección del dispositivo de fijación Translated title: Displacement of venous catheters of eco-guided puncture. Cross-sectional study on the influence of the efix strategy on the selection of the fixation device

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Resumen INTRODUCCIÓN: La canulación por micropunción ecodirigida de venas profundas del brazo aumenta la tasa de éxito al primer intento y reduce la probabilidad de complicaciones lo que redunda en la mejora de la eficiencia del procedimiento. El desplazamiento del catéter es una complicación evitable que se relaciona con mayor riesgo de flebitis, trombosis e infecciones, así como con mayor gasto económico y por tanto una disminución de la eficiencia del procedimiento. La estrategia de selección del dispositivo de fijación (eFIX) pretende ser una herramienta que minimize las posibilidades de desplazamiento del dispositivo de acceso vascilar (DAV). OBJETIVOS: General: Analizar la influencia de la estrategia “eFIX” para la selección del dispositivo de fijación sobre el desplazamiento de los catéteres venosos implantados con punción ecodirigida. Específico: Identificar la existencia de relación entre el desplazamiento del DAV y la aparición de trombosis, flebitis y BRC. MATERIAL Y MÉTODO: Se realizó estudio observacional analítico de corte transversal. Se incluyeron todas las inserciones exitosas realizadas en los pacientes mayores de 14 años ingresados en el Hospital Universitario de La Palma que cumplían criterios para un catéter venoso tipo Midline (ML) o Catéter Central de Inserción Periférica (CCIP) entre el 1 de julio de 2021 y el 30 de junio de 2022. Se identificó como variable dependiente el desplazamiento del catéter y como variable independiente la aplicación de la estrategia de selección del sistema de fijación (eFIX) (de elaboración propia) que incluye el uso rutinario de dispositivos adhesivos (DA) con tec-nología statlock y la selección de pacientes para el uso de anclajes subtutáneos (ASC) y adhesivo tisular. Análisis de da-tos con estadística descriptiva con medida de efecto OR. RESULTADOS: Se revisaron 378 registros. 171 (45,23%) corresponden al grupo sin aplicación de la eFIX identificando 25 casos (14,61%) de desplazamiento y 207 (54,76%) pertenecientes al grupo con aplicación de la eFIX identificando 11 casos (5,31%) de desplazamiento. Resultando un OR= 0.32 con error estándar de 0,37 y IC 95% (0,68 y 0,15). IC 99% (0,86 y 0,12). En el primer grupo se identificaron 7 casos (4%) de trombosis, 1 caso (0,5%) de flebitis y 0 casos de infecciones. En el segundo grupo se identificaron 7 casos (3,38%) de trombosis, 0 casos de flebitis y 0 casos de infecciones. DISCUSIÓN: Los datos muestran una disminución del desplazamiento del catéter en los pacientes con aplicación de la eFIX. Según los resultados obtenidos, la aplicación de esta estrategia influye en la disminución del desplazamiento al discriminar el uso de DA y ASC atendiendo al bajo riesgo de desplazamiento atribuible al ASC (0-1,5%) en comparación con el 14-20% atribuibles a los DA. El estudio puede estar limitado por sesgos de selección y confusión pero los resultados abren la puerta a futuros estudios. CONCLUSIÓN: Se consideró un factor influyente la aplicación de la estrategia de selección del sistema de fijación en la disminución de la prevalencia del desplazamiento de los catéteres venosos de punción ecodirigida y sus complicaciones relacionadas.

          Translated abstract

          Abstract: INTRODUCTION: Ultrasound-guided micropuncture cannulation of deep veins of the arm increases the success rate at the first attempt and reduces the probability of complications, which results in an improvement in the efficiency of the procedure. Displacement of the catheter is an avoidable complication that is related to a higher risk of phlebitis, thrombosis, and infectionsb as well as greater financial costs and, therefore, a decrease in the efficiency of the procedure. OBJECTIVE: To analyze the influence of the "eFIX" fixation device selection strategy on the displacement of venous catheters implanted with ultrasound-guided puncture. MATERIAL AND METHOD: A cross-sectional analytical observational study was carried out. It included all patients older than 14 years admitted to the University Hospital of La Palma who met the criteria for a Midline (ML) or Central Peripherally Inserted Catheter (PICC) between July 1, 2021 and June 30. 2022. Displacement of the catheter was identified as a dependent variable and the application of the self-made fixation system selection strategy (eFIX) as an independent variable, which includes the routine use of adhesive devices (AD) with statlock technology and the selection of patients for the use of subcutaneous anchors (ASC) and tissue adhesive. Data analysis with descriptive statistics with OR effect measure. RESULTS: 378 records were reviewed. 171 (45.23%) correspond to the group without application of eFIX, identifying 25 cases (14.61%) of displacement and 207 (54.76%) belonging to the group with application of eFIX, identifying 11 cases (5.31%). ) of displacement. Resulting in an OR= 0.32 with a standard error of 0.37 and a 95% CI (0.68 and 0.15). CI 99% (0.86 and 0.12) In the first group, 7 cases (4%) of thrombosis, 1 case (0.5%) of phlebitis and 0 cases of infections were identified. In the second group, 7 cases (3.38%) of thrombosis, 0 cases of phlebitis and 0 cases of infections were identified. DISCUSSION: The data show a decrease in catheter displacement in patients with eFIX application. It seems that the application of this strategy influences the decrease in displacement by discriminating the use of AD and ASC based on the low risk of displacement attributable to ASC (0-1.5%) f compared to the 14-20% attributable to DAe. The study may be limited by selection bias and confounding, but the results open the door to future studies. CONLUSION: The application of the fixation system selection strategy was considered an influential factor in reducing the prevalence of displacement of venous ultrasound-guided puncture catheters and related complications.

          Related collections

          Most cited references17

          • Record: found
          • Abstract: found
          • Article: not found

          Reduction of bacterial colonization at the exit site of peripherally inserted central catheters: A comparison between chlorhexidine-releasing sponge dressings and cyano-acrylate.

          A serious complication associated with Central Venous Access Device (CVAD) is infection because of bacterial contamination, either by the extra-luminal or by the intra-luminal route.We evaluated the efficacy, the safety, and the cost-effectiveness of two strategies for non-inferiority in controlling bacterial colonization of the exit-site of Peripherally-Inserted Central Catheters (PICC).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Cumulative experience with 1,273 peripherally inserted central catheters at a single institution.

            To compare bedside insertion of peripherally inserted central catheters (PICCs) by specially-trained nurses with insertion by cardiovascular and interventional radiologists.
              Bookmark
              • Record: found
              • Abstract: not found
              • Book: not found

              Guía de Buenas Prácticas. Acceso Vascular

              (2021)
                Bookmark

                Author and article information

                Journal
                ene
                Ene
                Ene.
                Martín Rodríguez Álvaro (Santa Cruz de La Palma, La Palma, Spain )
                1988-348X
                2023
                : 17
                : 1
                : 1928
                Affiliations
                [1] Canarias orgnameServicio Canario de Salud orgdiv1Hospital Universitario de La Palma España
                Article
                S1988-348X2023000100002 S1988-348X(23)01700100002
                e23fbfd1-a5e6-4ba1-b3fa-06deb3726d7e

                This work is licensed under a Creative Commons Attribution 4.0 International License.

                History
                : November 2022
                : November 2022
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 17, Pages: 0
                Product

                SciELO Spain

                Categories
                Artículos

                infecciones relacionadas con catéteres,protocolos clínicos,Displacement,venous catheter,ultrasound-guided puncture,complications and fixation device,Dispositivos de acceso vascular,ultrasonografía intervencional,efectos adversos

                Comments

                Comment on this article