      Simultaneous sEMG Classification of Hand/Wrist Gestures and Forces

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Surface electromyography (sEMG) signals represent a promising approach for decoding the motor intention of amputees to control a multifunctional prosthetic hand in a non-invasive way. Several approaches based on proportional amplitude methods or simple thresholds on sEMG signals have been proposed to control a single degree of freedom at time, without the possibility of increasing the number of controllable multiple DoFs in a natural manner. Myoelectric control based on PR techniques have been introduced to add multiple DoFs by keeping low the number of electrodes and allowing the discrimination of different muscular patterns for each class of motion. However, the use of PR algorithms to simultaneously decode both gestures and forces has never been studied deeply. This paper introduces a hierarchical classification approach with the aim to assess the desired hand/wrist gestures, as well as the desired force levels to exert during grasping tasks. A Finite State Machine was introduced to manage and coordinate three classifiers based on the Non-Linear Logistic Regression algorithm. The classification architecture was evaluated across 31 healthy subjects. The “hand/wrist gestures classifier,” introduced for the discrimination of seven hand/wrist gestures, presented a mean classification accuracy of 98.78%, while the “Spherical and Tip force classifier,” created for the identification of three force levels, reached an average accuracy of 98.80 and 96.09%, respectively. These results were confirmed by Linear Discriminant Analysis (LDA) with time domain features extraction, considered as ground truth for the final validation of the performed analysis. A Wilcoxon Signed-Rank test was carried out for the statistical analysis of comparison between NLR and LDA and statistical significance was considered at p < 0.05. The comparative analysis reports not statistically significant differences in terms of F1Score performance between NLR and LDA. Thus, this study reveals that the use of non-linear classification algorithm, as NLR, is as much suitable as the benchmark LDA classifier for implementing an EMG pattern recognition system, able both to decode hand/wrist gestures and to associate different performed force levels to grasping actions.

          Related collections

          Most cited references42

          • Record: found
          • Abstract: not found
          • Article: not found

          Statistical comparisons of classifiers over multiple data sets

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            A comparison of surface and intramuscular myoelectric signal classification.

            The surface myoelectric signal (MES) has been used as an input to controllers for powered prostheses for many years. As a result of recent technological advances it is reasonable to assume that there will soon be implantable myoelectric sensors which will enable the internal MES to be used as input to these controllers. An internal MES measurement should have less muscular crosstalk allowing for more independent control sites. However, it remains unclear if this benefit outweighs the loss of the more global information contained in the surface MES. This paper compares the classification accuracy of six pattern recognition-based myoelectric controllers which use multi-channel surface MES as inputs to the same controllers which use multi-channel intramuscular MES as inputs. An experiment was designed during which surface and intramuscular MES were collected simultaneously for 10 different classes of isometric contraction. There was no significant difference in classification accuracy as a result of using the intramuscular MES measurement technique when compared to the surface MES measurement technique. Impressive classification accuracy (97%) could be achieved by optimally selecting only three channels of surface MES.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Determining the optimal window length for pattern recognition-based myoelectric control: balancing the competing effects of classification error and controller delay.

              Pattern recognition-based control of myoelectric prostheses has shown great promise in research environments, but has not been optimized for use in a clinical setting. To explore the relationship between classification error, controller delay, and real-time controllability, 13 able-bodied subjects were trained to operate a virtual upper-limb prosthesis using pattern recognition of electromyogram (EMG) signals. Classification error and controller delay were varied by training different classifiers with a variety of analysis window lengths ranging from 50 to 550 ms and either two or four EMG input channels. Offline analysis showed that classification error decreased with longer window lengths (p < 0.01 ). Real-time controllability was evaluated with the target achievement control (TAC) test, which prompted users to maneuver the virtual prosthesis into various target postures. The results indicated that user performance improved with lower classification error (p < 0.01 ) and was reduced with longer controller delay (p < 0.01 ), as determined by the window length. Therefore, both of these effects should be considered when choosing a window length; it may be beneficial to increase the window length if this results in a reduced classification error, despite the corresponding increase in controller delay. For the system employed in this study, the optimal window length was found to be between 150 and 250 ms, which is within acceptable controller delays for conventional multistate amplitude controllers.
                Bookmark

                Author and article information

                Contributors
                Journal
                Front Neurorobot
                Front Neurorobot
                Front. Neurorobot.
                Frontiers in Neurorobotics
                Frontiers Media S.A.
                1662-5218
                19 June 2019
                2019
                : 13
                : 42
                Affiliations
                [1] 1Unit of Biomedical Robotics and Biomicrosystems, Universiã Bio-Medico di Roma , Rome, Italy
                [2] 2Italian Workers' Compensation Authority (INAIL), Vigorso di Budrio , Bologna, Italy
                Author notes

                Edited by: Toshiaki Tsuji, Saitama University, Japan

                Reviewed by: Levi Hargrove, Rehabilitation Institute of Chicago, United States; Farong Gao, Hangzhou Dianzi University, China

                *Correspondence: Francesca Leone f.leone@ 123456unicampus.it
                Article
                10.3389/fnbot.2019.00042
                6593108
                31275131
                e530de93-8e7c-4755-9683-d39e5ee10438
                Copyright © 2019 Leone, Gentile, Ciancio, Gruppioni, Davalli, Sacchetti, Guglielmelli and Zollo.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 02 February 2019
                : 31 May 2019
                Page count
                Figures: 10, Tables: 5, Equations: 9, References: 50, Pages: 15, Words: 9734
                Categories
                Neuroscience
                Original Research

                Robotics
                pattern recognition,surface electromyography,hand gestures recognition,prostheses,gestures classifier,force classifiers,non-linear logistic regression,linear discriminant analysis

                Comments

                Comment on this article