      Fifteen years’ experience of implantable cardioverter defibrillator in children and young adults: Mortality and complications study

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references29

          • Record: found
          • Abstract: not found
          • Article: not found

          Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA).

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Outcome and complications after implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy: systematic review and meta-analysis.

            Previous observational studies demonstrated that patients with hypertrophic cardiomyopathy at risk for sudden cardiac death (SCD) may benefit from implantable cardioverter defibrillator (ICD) therapy. A complete overview of outcome and complications after ICD therapy is currently not available. This study pools data from published studies on outcome and complications after ICD therapy in patients with hypertrophic cardiomyopathy. A PubMed database search returned 27 studies on 16 cohorts reporting outcome and complications after ICD therapy in patients with hypertrophic cardiomyopathy. In case of >1 publications on a particular cohort, the publication with the largest number of patients was included in the meta-analysis. ICD interventions, complications, and mortality rates were extracted, pooled, and analyzed. There were 2190 patients (mean age, 42 years; 38% women), most of whom (83%) received an ICD for primary prevention of SCD. Risk factors for SCD were left ventricular wall thickness ≥30 mm (20%), family history of SCD (43%), nonsustained ventricular tachycardia (46%), syncope (41%), and abnormal blood pressure response (25%). During the 3.7-year follow-up, the annualized cardiac mortality rate was 0.6%, the noncardiac mortality rate was 0.4%, and the appropriate ICD intervention rate was 3.3%. The annualized inappropriate ICD intervention rate was 4.8% and the annualized ICD-related complication rate was 3.4%. This meta-analysis demonstrates a low cardiac and noncardiac mortality rate after ICD therapy in patients with hypertrophic cardiomyopathy. Appropriate ICD intervention occurred at a rate of 3.3%/year, thereby, most probably, preventing SCD. Inappropriate ICD intervention and complications are not uncommon.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Deaths and cardiovascular injuries due to device-assisted implantable cardioverter–defibrillator and pacemaker lead extraction

              Aims An estimated 10 000–15 000 pacemaker and implantable cardioverter–defibrillator (ICD) leads are extracted annually worldwide using specialized tools that disrupt encapsulating fibrous tissue. Additional information is needed regarding the safety of the devices that have been approved for lead extraction. The aim of this study was to determine whether complications due to device-assisted lead extraction might be more hazardous than published data suggest, and whether procedural safety precautions are effective. Methods and results We searched the US Food and Drug Administration's (FDA) Manufacturers and User Defined Experience (MAUDE) database from 1995 to 2008 using the search terms ‘lead extraction and death’ and ‘lead extraction and injury’. Additional product specific searches were performed for the terms ‘death’ and ‘injury’. Between 1995 and 2008, 57 deaths and 48 serious cardiovascular injuries associated with device-assisted lead extraction were reported to the FDA. Owing to underreporting, the FDA database does not contain all adverse events that occurred during this period. Of the 105 events, 27 deaths and 13 injuries occurred in 2007–2008. During these 2 years, 23 deaths were linked with excimer laser or mechanical dilator sheath extractions. The majority of deaths and injuries involved ICD leads, and most were caused by lacerations of the right atrium, superior vena cava, or innominate vein. Overall, 62 patients underwent emergency surgical repair of myocardial perforations and venous lacerations and 35 (56%) survived. Conclusion These findings suggest that device-assisted lead extraction is a high-risk procedure and that serious complications including death may not be mitigated by emergency surgery. However, skilled standby cardiothoracic surgery is essential when performing pacemaker and ICD lead extractions. Although the incidence of these complications is unknown, the results of our study imply that device-assisted lead extractions should be performed by highly qualified physicians and their teams in specialized centres.
                Bookmark

                Author and article information

                Journal
                Pediatrics International
                Pediatrics International
                Wiley
                13288067
                October 2018
                October 2018
                October 21 2018
                : 60
                : 10
                : 923-930
                Affiliations
                [1 ]National Institute of Cardiology; Warsaw Poland
                Article
                10.1111/ped.13660
                29998526
                e6068cc9-4370-4e15-b09f-0739b6f868a1
                © 2018

                http://doi.wiley.com/10.1002/tdm_license_1.1

                http://onlinelibrary.wiley.com/termsAndConditions#vor

                History

                Comments

                Comment on this article