4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      A1C Underperforms as a Diagnostic Test in Africans Even in the Absence of Nutritional Deficiencies, Anemia and Hemoglobinopathies: Insight From the Africans in America Study

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction: To improve detection of undiagnosed diabetes in Africa, there is movement to replace the OGTT with A1C. The performance of A1C in the absence of hemoglobin-related micronutrient deficiencies, anemia and heterozygous hemoglobinopathies is unknown. Therefore, we determined in 441 African-born blacks living in America [male: 65% (281/441), age: 38 ± 10 y (mean ± SD), BMI: 27.5 ± 4.4 kg/m 2] (1) nutritional and hematologic profiles and (2) glucose tolerance categorization by OGTT and A1C.

          Methods: Hematologic and nutritional status were assessed. Hemoglobin <11 g/dL occurred in 3% (11/441) of patients and led to exclusion. A1C and OGTT were performed in the remaining 430 participants. ADA thresholds for A1C and OGTT were used. Diagnosis by A1C required meeting either A1C-alone or A1C&OGTT criteria. Diagnosis by OGTT-alone required detection by OGTT and not A1C.

          Results: Hemoglobin, mean corpuscular volume and red blood cell distribution width were 14.0 ± 1.3 g/dL, 85.5 ± 5.3 fL, and 13.2 ± 1.2% respectively. B12, folate, and iron deficiency occurred in 1% (5/430), 0% (0/430), and 4% (12/310), respectively. Heterozygous hemoglobinopathy prevalence was 18% (78/430). Overall, diabetes prevalence was 7% (32/430). A1C detected diabetes in 32% (10/32) but OGTT-alone detected 68% (22/32). Overall prediabetes prevalence was 41% (178/430). A1C detected 57% (102/178) but OGTT-alone identified 43% (76/178). After excluding individuals with heterozygous hemoglobinopathies, the rate of missed diagnosis by A1C of abnormal glucose tolerance did not change (OR: 0.99, 95% CI: 0.61, 1.62).

          Conclusions: In nutritionally replete Africans without anemia or heterozygous hemoglobinopathy, if only A1C is used, ~60% with diabetes and ~40% with prediabetes would be undiagnosed.

          Clinical Trial Registration:: www.ClinicalTrials.gov, Identifier: NCT00001853

          Related collections

          Most cited references25

          • Record: found
          • Abstract: not found
          • Article: not found

          Classification and diagnosis of diabetes mellitus and other categories of glucose intolerance. National Diabetes Data Group.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Effects of intensive glucose control on microvascular outcomes in patients with type 2 diabetes: a meta-analysis of individual participant data from randomised controlled trials.

            Intensive glucose control is understood to prevent complications in adults with type 2 diabetes. We aimed to more precisely estimate the effects of more intensive glucose control, compared with less intensive glucose control, on the risk of microvascular events.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              A1C Versus Glucose Testing: A Comparison

              Diabetes was originally identified by the presence of glucose in the urine. Almost 2,500 years ago it was noticed that ants were attracted to the urine of some individuals. In the 18th and 19th centuries the sweet taste of urine was used for diagnosis before chemical methods became available to detect sugars in the urine. Tests to measure glucose in the blood were developed over 100 years ago, and hyperglycemia subsequently became the sole criterion recommended for the diagnosis of diabetes. Initial diagnostic criteria relied on the response to an oral glucose challenge, while later measurement of blood glucose in an individual who was fasting also became acceptable. The most widely accepted glucose-based criteria for diagnosis are fasting plasma glucose (FPG) ≥126 mg/dL or a 2-h plasma glucose ≥200 mg/dL during an oral glucose tolerance test (OGTT) on more than one occasion (1,2). In a patient with classic symptoms of diabetes, a single random plasma glucose ≥200 mg/dL is considered diagnostic (1). Before 2010 virtually all diabetes societies recommended blood glucose analysis as the exclusive method to diagnose diabetes. Notwithstanding these guidelines, over the last few years many physicians have been using hemoglobin A1C to screen for and diagnose diabetes (3). Although considered the “gold standard” for diagnosis, measurement of glucose in the blood is subject to several limitations, many of which are not widely appreciated. Measurement of A1C for diagnosis is appealing but has some inherent limitations. These issues have become the focus of considerable attention with the recent publication of the Report of the International Expert Committee that recommended the use of A1C for diagnosis of diabetes (4), a position that has been endorsed (at the time of writing) by the American Diabetes Association (ADA) (1), the Endocrine Society, and in a more limited fashion by American Association of Clinical Endocrinologists/American College of Endocrinology (5). This review will provide an overview of the factors that influence glucose and A1C testing. FACTORS CONTRIBUTING TO VARIATION IN RESULTS Before addressing glucose and A1C, it is important to consider the factors that impact the results of any blood test. While laboratory medicine journals have devoted some discussion to the sources of variability in results of blood tests, this topic has received little attention in the clinical literature. Factors that contribute to variation can conveniently be divided into three categories, namely biological, preanalytical, and analytical. Biological variation comprises both differences within a single person (termed intraindividual) and between two or more people (termed interindividual). Preanalytical issues pertain to the specimen before it is measured. Analytical differences result from the measurement procedure itself. The influence of these factors on both glucose and A1C results will be addressed in more detail below. GLUCOSE MEASUREMENT FPG Measurement of glucose in plasma of fasting subjects is widely accepted as a diagnostic criterion for diabetes (1,2). Advantages include inexpensive assays on automated instruments that are available in most laboratories worldwide (Table 1). Nevertheless, FPG is subject to some limitations. One report that analyzed repeated measurements from 685 fasting participants without diagnosed diabetes from the Third National Health and Nutrition Examination Survey (NHANES III) revealed that only 70.4% of people with FPG ≥126 mg/dL on the first test had FPG ≥126 mg/dL when analysis was repeated ∼2 weeks later (6). Numerous factors may contribute to this lack of reproducibility. These are elaborated below. Table 1 FPG for the diagnosis of diabetes Advantages  • Glucose assay easily automated  • Widely available  • Inexpensive  • Single sample Disadvantages  • Patient must fast ≥8 h  • Large biological variability  • Diurnal variation  • Sample not stable  • Numerous factors alter glucose concentrations, e.g., stress, acute illness  • No harmonization of glucose testing  • Concentration varies with source of the sample (venous, capillary, or arterial blood)  • Concentration in whole blood is different from that in plasma  • Guidelines recommend plasma, but many laboratories measure serum glucose  • FPG less tightly linked to diabetes complications (than A1C)  • Reflects glucose homeostasis at a single point in time Biological variation Fasting glucose concentrations vary considerably both in a single person from day to day and also between different subjects. Intraindividual variation in a healthy person is reported to be 5.7–8.3%, whereas interindividual variation of up to 12.5% has been observed (6,7). Based on a CV (coefficient of variation) of 5.7%, FPG can range from 112–140 mg/dL in an individual with an FPG of 126 mg/dL. (It is important to realize that these values encompass the 95% confidence interval, and 5% of values will be outside this range.) Preanalytical variation Numerous factors that occur before a sample is measured can influence results of blood tests. Examples include medications, venous stasis, posture, and sample handling. The concentration of glucose in the blood can be altered by food ingestion, prolonged fasting, or exercise (8). It is also important that measurements are performed in subjects in the absence of intercurrent illness, which frequently produces transient hyperglycemia (9). Similarly, acute stress (e.g., not being able to find parking or having to wait) can alter blood glucose concentrations. Samples for fasting glucose analysis should be drawn after an overnight fast (no caloric ingestion for at least 8 h), during which time the subject may consume water ad lib (10). The requirement that the subject be fasting is a considerable practical problem as patients are usually not fasting when they visit the doctor, and it is often inconvenient to return for phlebotomy. For example, at an HMO affiliated with an academic medical center, 69% (5,752 of 8,286) of eligible participants were screened for diabetes (11). However, FPG was performed on only 3% (152) of these individuals. Ninety-five percent (5,452) of participants were screened by random plasma glucose measurements, a technique not consistent with ADA recommendations. In addition, blood drawn in the morning as FPG has a diurnal variation. Analysis of 12,882 participants aged 20 years or older in NHANES III who had no previously diagnosed diabetes revealed that mean FPG in the morning was considerably higher than in the afternoon (12). Prevalence of diabetes (FPG ≥126 mg/dL) in afternoon-examined patients was half that of participants examined in the morning. Other patient-related factors that can influence the results include food ingestion when supposed to be fasting and hypocaloric diet for a week or more prior to testing. Glucose concentrations decrease in the test tube by 5–7% per hour due to glycolysis (13). Therefore, a sample with a true blood glucose value of 126 mg/dL would have a glucose concentration of ∼110 mg/dL after 2 h at room temperature. Samples with increased concentrations of erythrocytes, white blood cells, or platelets have even greater rates of glycolysis. A common misconception is that sodium fluoride, an inhibitor of glycolysis, prevents glucose consumption. While fluoride does attenuate in vitro glycolysis, it has no effect on the rate of decline in glucose concentrations in the first 1 to 2 h after blood is collected, and glycolysis continues for up to 4 h in samples containing fluoride (14). The delay in the glucose stabilizing effect of fluoride is most likely the result of glucose metabolism proximal to the fluoride target enolase (15). After 4 h, fluoride maintains a stable glucose concentration for 72 h at room temperature (14). A recent publication showed that acidification of the blood sample inhibits glycolysis in the first 2 h after phlebotomy (16), but the collection tubes used in that study are not commercially available. Placing tubes in ice water immediately after collection may be the best method to stabilize glucose initially (2,16), but this is not a practical solution in most clinical situations. Separating cells from plasma within minutes is also effective, but impractical. The nature of the specimen analyzed can have a large influence on the glucose concentration. Glucose can be measured in whole blood, serum, or plasma, but plasma is recommended by both the ADA and World Health Organization (WHO) for diagnosis (1,2). However, many laboratories measure glucose in serum, and these values may differ from those in plasma. There is a lack of consensus in the published literature, with glucose concentrations in plasma reported to be lower than (17), higher than (16,18,19), or the same as (20) those in serum. Importantly, glucose concentrations in whole blood are 11% lower than those in plasma because erythrocytes have a lower water content than plasma (13). The magnitude of the difference in glucose between whole blood and plasma changes with hematocrit. Most devices (usually handheld meters) that measure glucose in capillary blood use whole blood. While the majority of these report a plasma equivalent glucose value (21), this result is not accurate in patients with anemia (22) (unless the meter measures hematocrit). The source of the blood is another variable. Although not a substantial problem in the fasting state, capillary glucose concentrations can be 20–25% higher (mean of 30 mg/dL) than venous glucose during an OGTT (23). This finding has practical implications for the OGTT, particularly because the WHO deems capillary blood samples acceptable for the diagnosis of diabetes (2). Analytical variation Glucose is measured in central laboratories almost exclusively using enzymatic methods, predominantly with glucose oxidase or hexokinase (24). The following terms are important for understanding measurement: accuracy indicates how close a single measurement is to the “true value” and precision (or repeatability) refers to the closeness of agreement of repeated measurements under the same conditions. Precision is usually expressed as CV; methods with low CV have high precision. Numerous improvements in glucose measurement have produced low within-laboratory imprecision (CV 12% of patients (4). Similarly, inspection of a College of American Pathologists (CAP) survey comprising >5,000 laboratories revealed that one-third of the time the results among instruments for an individual measurement could range between 141 and 162 mg/dL (26). This variation of 6.9% above or below the mean reveals that one-third of the time the glucose results on a single patient sample measured in two different laboratories could differ by 14%. OGTT The OGTT evaluates the efficiency of the body to metabolize glucose and for many years has been used as the “gold standard” for diagnosis of diabetes. An increase in postprandial glucose concentration usually occurs before fasting glucose increases. Therefore, postprandial glucose is a sensitive indicator of the risk for developing diabetes and an early marker of impaired glucose homeostasis (Table 2). Published evidence suggests that an increased 2-h plasma glucose during an OGTT is a better predictor of both all-cause mortality and cardiovascular mortality or morbidity than the FPG (27,28). The OGTT is accepted as a diagnostic modality by the ADA, WHO/International Diabetes Federation (IDF) (1,2), and other organizations. However, extensive patient preparation is necessary to perform an OGTT. Important conditions include, among others, ingestion of at least 150 g of dietary carbohydrate per day for 3 days prior to the test, a 10- to 16-h fast, and commencement of the test between 7:00 a.m. and 9:00 a.m. (24). In addition, numerous conditions other than diabetes can influence the OGTT (24). Consistent with this, published evidence reveals a high degree of intraindividual variability in the OGTT, with a CV of 16.7%, which is considerably greater than the variability for FPG (6). These factors result in poor reproducibility of the OGTT, which has been documented in multiple studies (29,30). The lack of reproducibility, inconvenience, and cost of the OGTT led the ADA to recommend that FPG should be the preferred glucose-based diagnostic test (1). Note that glucose measurement in the OGTT is also subject to all the limitations described for FPG (Table 1). Table 2 OGTT for the diagnosis of diabetes Advantages  • Sensitive indicator of risk of developing diabetes  • Early marker of impaired glucose homeostasis Disadvantages  • Lacks reproducibility  • Extensive patient preparation  • Time-consuming and inconvenient for patients  • Unpalatable  • Expensive  • Influenced by numerous medications  • Subject to the same limitations as FPG, namely, sample not stable, needs to be performed in the morning, etc. A1C MEASUREMENT A1C is formed by the nonenzymatic attachment of glucose to the N-terminal valine of the β-chain of hemoglobin (24). The life span of erythrocytes is ∼120 days, and consequently A1C reflects long-term glycemic exposure, representing the average glucose concentration over the preceding 8–12 weeks (31,32). Both observational studies (33) and controlled clinical trials (34,35) demonstrate strong correlation between A1C and retinopathy, as well as other microvascular complications of diabetes. More importantly, the A1C value predicts the risk of microvascular complications and lowering A1C concentrations (by tight glycemic control) significantly reduces the rate of progression of microvascular complications (34,35). Biological variation Intraindividual variation of A1C in nondiabetic people is minimal (36) (Table 3), with CV 15% or if a large change in A1C coincides with a change in laboratory A1C method (53). In these situations, hemoglobin electrophoresis should be performed. It is important to emphasize that, like any other test, A1C results that are inconsistent with the clinical presentation should be investigated. PERSPECTIVE Notwithstanding the use of glucose (FPG and/or the OGTT) as the “gold standard” for the diagnosis of diabetes for many years, glucose testing suffers from several deficiencies. The requirement that the subject be fasting at the time the blood is drawn is a considerable inconvenience. While our ability to measure glucose has improved, inherent biological variability can produce very large differences within and among individuals. In conjunction with lack of sample stability, which is difficult to overcome in clinical practice, these factors results in lack of reproducibility of glucose testing. A1C, which reflects chronic blood glucose values, is routinely used in monitoring glycemic control and guiding therapy. The significant reduction in microvascular complications with lower A1C and the absence of sample lability, combined with several other advantages (Table 3), have led to the recommendation by some organizations that A1C be used for screening and diagnosis of diabetes (1). Accumulating evidence suggests that racial differences in A1C values may be present, and the possible clinical significance of this needs to be determined. Importantly, A1C cannot be measured in certain conditions. Despite these caveats, A1C can be measured accurately in the vast majority of people. A comprehension of the factors that influence A1C values and the conditions where it should not be used will produce accurate and clinically meaningful results. The convenience of sampling at any time without regard to food ingestion makes it likely that measurement of A1C will result in the detection of many of the millions of people with diabetes who are currently undiagnosed.
                Bookmark

                Author and article information

                Contributors
                Journal
                Front Endocrinol (Lausanne)
                Front Endocrinol (Lausanne)
                Front. Endocrinol.
                Frontiers in Endocrinology
                Frontiers Media S.A.
                1664-2392
                07 August 2019
                2019
                : 10
                : 533
                Affiliations
                [1] 1Diabetes, Endocrinology, and Obesity Branch, National Institute of Diabetes, Digestive and Kidney Diseases, National Institutes of Health , Bethesda, MD, United States
                [2] 2National Institute of Minority Health and Health Disparities, National Institutes of Health , Bethesda, MD, United States
                [3] 3Laboratory of Biological Modeling Medicine, National Institute of Diabetes, Digestive and Kidney Diseases, National Institutes of Health , Bethesda, MD, United States
                Author notes

                Edited by: Solomon Tesfaye, Sheffield Teaching Hospitals NHS Foundation Trust, United Kingdom

                Reviewed by: Jan Brož, Second Faculty of Medicine, Charles University, Czechia; Joseph Aloi, Wake Forest Baptist Medical Center, United States

                *Correspondence: Anne E. Sumner annes@ 123456mail.nih.gov

                This article was submitted to Diabetes, a section of the journal Frontiers in Endocrinology

                Article
                10.3389/fendo.2019.00533
                6692432
                31447780
                e6fb7bef-a353-45e0-abfa-deb36ab348c2
                Copyright © 2019 Briker, Aduwo, Mugeni, Horlyck-Romanovsky, DuBose, Mabundo, Hormenu, Chung, Ha, Sherman and Sumner.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 06 May 2019
                : 18 July 2019
                Page count
                Figures: 3, Tables: 1, Equations: 3, References: 35, Pages: 9, Words: 6021
                Funding
                Funded by: National Institutes of Health 10.13039/100000002
                Categories
                Endocrinology
                Original Research

                Endocrinology & Diabetes
                diabetes,africans,sickle cell trait,anemia,a1c
                Endocrinology & Diabetes
                diabetes, africans, sickle cell trait, anemia, a1c

                Comments

                Comment on this article