81
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      volBrain: An Online MRI Brain Volumetry System

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The amount of medical image data produced in clinical and research settings is rapidly growing resulting in vast amount of data to analyze. Automatic and reliable quantitative analysis tools, including segmentation, allow to analyze brain development and to understand specific patterns of many neurological diseases. This field has recently experienced many advances with successful techniques based on non-linear warping and label fusion. In this work we present a novel and fully automatic pipeline for volumetric brain analysis based on multi-atlas label fusion technology that is able to provide accurate volumetric information at different levels of detail in a short time. This method is available through the volBrain online web interface ( http://volbrain.upv.es), which is publically and freely accessible to the scientific community. Our new framework has been compared with current state-of-the-art methods showing very competitive results.

          Related collections

          Most cited references37

          • Record: found
          • Abstract: found
          • Article: not found

          Adaptive non-local means denoising of MR images with spatially varying noise levels.

          To adapt the so-called nonlocal means filter to deal with magnetic resonance (MR) images with spatially varying noise levels (for both Gaussian and Rician distributed noise). Most filtering techniques assume an equal noise distribution across the image. When this assumption is not met, the resulting filtering becomes suboptimal. This is the case of MR images with spatially varying noise levels, such as those obtained by parallel imaging (sensitivity-encoded), intensity inhomogeneity-corrected images, or surface coil-based acquisitions. We propose a new method where information regarding the local image noise level is used to adjust the amount of denoising strength of the filter. Such information is automatically obtained from the images using a new local noise estimation method. The proposed method was validated and compared with the standard nonlocal means filter on simulated and real MRI data showing an improved performance in all cases. The new noise-adaptive method was demonstrated to outperform the standard filter when spatially varying noise is present in the images. (c) 2009 Wiley-Liss, Inc.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images.

            A critical issue in image restoration is the problem of noise removal while keeping the integrity of relevant image information. Denoising is a crucial step to increase image quality and to improve the performance of all the tasks needed for quantitative imaging analysis. The method proposed in this paper is based on a 3-D optimized blockwise version of the nonlocal (NL)-means filter (Buades, et al., 2005). The NL-means filter uses the redundancy of information in the image under study to remove the noise. The performance of the NL-means filter has been already demonstrated for 2-D images, but reducing the computational burden is a critical aspect to extend the method to 3-D images. To overcome this problem, we propose improvements to reduce the computational complexity. These different improvements allow to drastically divide the computational time while preserving the performances of the NL-means filter. A fully automated and optimized version of the NL-means filter is then presented. Our contributions to the NL-means filter are: 1) an automatic tuning of the smoothing parameter; 2) a selection of the most relevant voxels; 3) a blockwise implementation; and 4) a parallelized computation. Quantitative validation was carried out on synthetic datasets generated with BrainWeb (Collins, et al., 1998). The results show that our optimized NL-means filter outperforms the classical implementation of the NL-means filter, as well as two other classical denoising methods [anisotropic diffusion (Perona and Malik, 1990)] and total variation minimization process (Rudin, et al., 1992) in terms of accuracy (measured by the peak signal-to-noise ratio) with low computation time. Finally, qualitative results on real data are presented .
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Morphometric analysis of white matter lesions in MR images: method and validation.

              The analysis of MR images is evolving from qualitative to quantitative. More and more, the question asked by clinicians is how much and where, rather than a simple statement on the presence or absence of abnormalities. The authors present a study in which the results obtained with a semiautomatic, multispectral segmentation technique are quantitatively compared to manually delineated regions. The core of the semiautomatic image analysis system is a supervised artificial neural network classifier augmented with dedicated preand postprocessing algorithms, including anisotropic noise filtering and a surface-fitting method for the correction of spatial intensity variations. The study was focused on the quantitation of white matter lesions in the human brain. A total of 36 images from six brain volumes was analyzed twice by each of two operators, under supervision of a neuroradiologist. Both the intra- and interrater variability of the methods were studied in terms of the average tissue area detected per slice, the correlation coefficients between area measurements, and a measure of similarity derived from the kappa statistic. The results indicate that, compared to a manual method, the use of the semiautomatic technique not only facilitates the analysis of the images, but also has similar or lower intra- and interrater variabilities.
                Bookmark

                Author and article information

                Contributors
                Journal
                Front Neuroinform
                Front Neuroinform
                Front. Neuroinform.
                Frontiers in Neuroinformatics
                Frontiers Media S.A.
                1662-5196
                27 July 2016
                2016
                : 10
                : 30
                Affiliations
                [1] 1Instituto de Aplicaciones de las Tecnologías de la Información y de las Comunicaciones Avanzadas (ITACA), Universitat Politècnica de València Valencia, Spain
                [2] 2Pictura Research Group, Unité Mixte de Recherche Centre National de la Recherche Scientifique (UMR 5800), Laboratoire Bordelais de Recherche en Informatique, Centre National de la Recherche Scientifique Talence, France
                [3] 3Pictura Research Group, Unité Mixte de Recherche Centre National de la Recherche Scientifique (UMR 5800), Laboratoire Bordelais de Recherche en Informatique, University Bordeaux Talence, France
                Author notes

                Edited by: Arjen Van Ooyen, Vrije Universiteit (VU) Amsterdam, Netherlands

                Reviewed by: Graham J. Galloway, Translational Research Institute, Australia; Xi-Nian Zuo, Chinese Academy of Sciences, China

                *Correspondence: José V. Manjón jmanjon@ 123456fis.upv.es
                Article
                10.3389/fninf.2016.00030
                4961698
                27512372
                e7197fa2-3410-405c-b253-37f8b5d55187
                Copyright © 2016 Manjón and Coupé.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 20 March 2016
                : 11 July 2016
                Page count
                Figures: 6, Tables: 3, Equations: 0, References: 53, Pages: 14, Words: 8951
                Funding
                Funded by: Agence Nationale de la Recherche 10.13039/501100001665
                Award ID: ANR-10-IDEX-03-02
                Funded by: Ministerio de Ciencia y Tecnología 10.13039/501100006280
                Award ID: TIN2013-43457-R
                Categories
                Neuroscience
                Technology Report

                Neurosciences
                mri,brain,segmentation,multi-atlas label fusion,cloud computing
                Neurosciences
                mri, brain, segmentation, multi-atlas label fusion, cloud computing

                Comments

                Comment on this article