15
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Endovascular Stent-Graft Placement for Vascular Failure of the Thoracic Aorta

      review-article

      Read this article at

      ScienceOpenPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          It still remains undetermined whether endovascular stent-graft placement (ESGP) is the optimal initial treatment for elective cases of thoracic aortic disease because of unknown long-term results. However, it is also recognized that ESGP contributes to better outcome as an initial treatment for aortic emergency, such as rupture, aortic injury, and complicated acute type B aortic dissection. Despite the fact that most patients are elderly, early mortality rates of ESGP are reportedly around 10% in cases of ruptured degenerative thoracic aortic aneurysm. Postoperative morbidity is also superior in ESGP compared with conventional open repair. Postoperative paraplegia has rarely occurred with ESGP. In cases of blunt aortic injury (BAI), other complications may also be present because of other serious injuries. ESGP has changed the surgical strategy for BAI and partially resolved some of the clinical dilemmas. Early mortality rate is almost zero when a stent graft can be placed before re-rupture. While BAI is a very good indication for ESGP, young patients need careful management and attention because of the unknown long-term outcome. In cases of complicated acute type B aortic dissection, the two main determinants of death, shock from rupture and visceral ischemia, could be managed by ESGP with or without conventional endovascular interventions. Recent reports disclosed less than 10% early mortality with ESGP for complicated acute aortic dissection. Even if the possibility of endotension remains, ESPG seems to be beneficial for these critical patients as the preferable initial treatment. The importance of close follow-up should be stressed to avoid some devastating late complications following ESGP.

          Related collections

          Most cited references85

          • Record: found
          • Abstract: found
          • Article: not found

          Transfemoral intraluminal graft implantation for abdominal aortic aneurysms.

          This study reports on animal experimentation and initial clinical trials exploring the feasibility of exclusion of an abdominal aortic aneurysm by placement of an intraluminal, stent-anchored, Dacron prosthetic graft using retrograde cannulation of the common femoral artery under local or regional anesthesia. Experiments showed that when a balloon-expandable stent was sutured to the partially overlapping ends of a tubular, knitted Dacron graft, friction seals were created which fixed the ends of the graft to the vessel wall. This excludes the aneurysm from circulation and allows normal flow through the graft lumen. Initial treatment in five patients with serious co-morbidities is described. Each patient had an individually tailored balloon diameter and diameter and length of their Dacron graft. Standard stents were used and the diameter of the stent-graft was determined by sonography, computed tomography, and arteriography. In three of them a cephalic stent was used without a distal stent. In two other patients both ends of the Dacron tubular stent were attached to stents using a one-third stent overlap. In these latter two, once the proximal neck of the aneurysm was reached, the sheath was withdrawn and the cephalic balloon inflated with a saline/contrast solution. The catheter was gently removed caudally towards the arterial entry site in the groin to keep tension on the graft, and the second balloon inflated so as to deploy the second stent. Four of the five patients had heparin reversal at the end of the procedure. We are encouraged by this early experience, but believe that further developments and more clinical trials are needed before this technique becomes widely used.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms.

            The usual treatment for thoracic aortic aneurysms is surgical replacement with a prosthetic graft, but the associated morbidity and mortality are considerable. We studied the use of transluminally placed endovascular stent-graft devices as an alternative to surgical repair. We evaluated the feasibility, safety, and effectiveness of transluminally placed stent-graft to treat descending thoracic aortic aneurysms in 13 patients over a 24-month period. Atherosclerotic, anastomotic, and post-traumatic true or false aneurysms and aortic dissections were treated. The mean diameter of the aneurysms was 6.1 cm (range, 5 to 8). The endovascular stent-grafts were custom-designed for each patient and were constructed of self-expanding stainless-steel stents covered with woven Dacron grafts. Endovascular placement of the stent-graft prosthesis was successful in all patients. There was complete thrombosis of the thoracic aortic aneurysm surrounding the stent-graft in 12 patients, and partial thrombosis in 1. Two patients initially had small, residual patent proximal tracts into the aneurysm sac, but both tracts thrombosed within two months after the procedure. In four patients, two prostheses were required to bridge the aneurysm adequately. There have been no deaths or instances of paraplegia, stroke, distal embolization, or infection during an average follow-up of 11.6 months. One patient with an extensive chronic aortic dissection required open surgical graft replacement four months later because of progressive dilatation of the arch. These preliminary results demonstrate that endovascular stent-graft repair is safe in highly selected patients with descending thoracic aortic aneurysms. This new method of treatment will, however, require careful long-term evaluation.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Nonpenetrating traumatic injury of the aorta.

                Bookmark

                Author and article information

                Journal
                Vasc Health Risk Manag
                Vascular Health and Risk Management
                Vascular Health and Risk Management
                Dove Medical Press
                1176-6344
                1178-2048
                June 2006
                June 2006
                : 2
                : 2
                : 109-116
                Affiliations
                [1 ]Department of Traumatology and Critical Care Medicine, Sapporo Medical University Sapporo, Japan
                [2 ]Department of Thoracic and Cardiovascular Surgery, Sapporo Medical University Sapporo, Japan
                Author notes
                Correspondence: Yoshihiko Kurimoto, Department of Traumatology and Critical Care Medicine, Sapporo Medical University, South 1 West 16, Chuoku, Sapporo 060-8543, Japan Tel +81 11 611 2111 Fax +81 11 611 4963 Email kurimoto@ 123456sapmed.ac.jp
                Article
                1993999
                17319454
                e7252b2e-363f-451c-ac28-45df3b385c1f
                © 2006 Dove Medical Press Limited. All rights reserved
                History
                Categories
                Review

                Cardiovascular Medicine
                aortic dissection,ruptured thoracic aortic aneurysm,stent graft,aortic injury,organ ischemia

                Comments

                Comment on this article