      Evaluation of passive samplers for assessment of community exposure to toxic air contaminants and related pollutants.

      Environmental Science & Technology
      Air Pollutants, analysis, Air Pollution, statistics & numerical data, California, Environmental Monitoring, instrumentation, methods, Hazardous Substances, Humans, Inhalation Exposure, Volatile Organic Compounds

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The precision, accuracy, and sampling rates of Radiello and Ogawa passive samplers were evaluated in the laboratory using a flow-through chamber and under field conditions prior to their use in the 2007 Harbor Community Monitoring Study (HCMS), a saturation monitoring campaign in the communities adjacent to the Ports of Los Angeles and Long Beach. Passive methods included Radiello samplers for volatile organic compounds (benzene, toluene, ethylbenzene, xylenes, 1,3-butadiene), aldehydes (formaldehyde, acetaldehyde, acrolein) and hydrogen sulfide, and Ogawa samplers for nitrogen oxides and sulfur dioxide. Additional experiments were conducted to study the robustness of the passive sampling methods under variable ambient wind speed, sampling duration, and storage time before analysis. Our experimentally determined sampling rates were in agreement with the rates published by Radiello and Ogawa with the following exceptions: we observed a diffusion rate of 22.4 ± 0.1 mL/min for benzene and 37.4 ± 1.5 mL/min for ethylbenzene compared to the Radiello published values of 27.8 and 25.7 mL/min, respectively. With few exceptions, the passive monitoring methods measured one-week average ambient concentrations of selected pollutants with sensitivity and precision comparable to conventional monitoring methods averaged over the same period. Radiello Carbograph 4 VOC sampler is not suitable for the collection of 1,3-butadiene due to backdiffusion. Results for the Radiello aldehyde sampler were inconclusive due to lack of reliable reference methods for all carbonyl compounds of interest.

          Related collections

          Author and article information

          Comments

          Comment on this article