20
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Value of variation index of inferior vena cava diameter in predicting fluid responsiveness in patients with circulatory shock receiving mechanical ventilation: a systematic review and meta-analysis

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Respiratory variations in the inferior vena cava diameter (ΔIVCD) have been studied extensively with respect to their value in predicting fluid responsiveness, but the results are conflicting. The aim of this meta-analysis was to explore the value of ΔIVCD for predicting fluid responsiveness in patients with circulatory shock receiving mechanical ventilation.

          Methods

          PubMed, Embase, and the Cochrane Central Register of Controlled Trials were searched up to June 2017. The diagnostic OR (DOR), sensitivity, and specificity were calculated. The summary ROC curve was estimated, and the area under the ROC curve (AUROC) was calculated.

          Results

          Overall, 603 patients were included in this review, 324 (53.7%) of whom were fluid-responsive. The cutoff values of ΔIVCD varied across studies, ranging from 8% to 21%. Heterogeneity between studies was assessed with an overall Q = 0.069, I 2 = 0%, and P = 0.483. The pooled sensitivity and specificity for the overall population were 0.69 (95% CI, 0.51–0.83) and 0.80 (95% CI, 0.66–0.89), respectively. The DOR was 9.28 (95% CI, 2.33–36.98). AUROCs were reported in five studies. Overall, the pooled AUROC was 0.82 (95% CI, 0.79–0.85).

          Conclusions

          The findings of this study suggest that the ΔIVCD performed moderately well in predicting fluid responsiveness in patients with circulatory shock receiving mechanical ventilation.

          Electronic supplementary material

          The online version of this article (10.1186/s13054-018-2063-4) contains supplementary material, which is available to authorized users.

          Related collections

          Most cited references18

          • Record: found
          • Abstract: not found
          • Article: not found

          Systematic reviews in health care: Systematic reviews of evaluations of diagnostic and screening tests.

          J J Deeks (2001)
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The respiratory variation in inferior vena cava diameter as a guide to fluid therapy.

            To investigate whether the respiratory variation in inferior vena cava diameter (DeltaD(IVC)) could be related to fluid responsiveness in mechanically ventilated patients. Prospective clinical study. Medical ICU of a non-university hospital. Mechanically ventilated patients with septic shock (n=39). Volume loading with 8 mL/kg of 6% hydroxyethylstarch over 20 min. Cardiac output and DeltaD(IVC) were assessed by echography before and immediately after the standardized volume load. Volume loading induced an increase in cardiac output from 5.7+/-2.0 to 6.4+/-1.9 L/min (P or =15% (responders). Before volume loading, the DeltaD(IVC) was greater in responders than in non-responders (25+/-15 vs 6+/-4%, P<0.001), closely correlated with the increase in cardiac output (r=0.82, P<0.001), and a 12% DeltaD(IVC) cut-off value allowed identification of responders with positive and negative predictive values of 93% and 92%, respectively. Analysis of DeltaD(IVC) is a simple and non-invasive method to detect fluid responsiveness in mechanically ventilated patients with septic shock.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients.

              To evaluate the extent to which respiratory changes in inferior vena cava (IVC) diameter can be used to predict fluid responsiveness. Prospective clinical study. Hospital intensive care unit. Twenty-three patients with acute circulatory failure related to sepsis and mechanically ventilated because of an acute lung injury. Inferior vena cava diameter (D) at end-expiration (Dmin) and at end-inspiration (Dmax) was measured by echocardiography using a subcostal approach. The distensibility index of the IVC (dIVC) was calculated as the ratio of Dmax - Dmin / Dmin, and expressed as a percentage. The Doppler technique was applied in the pulmonary artery trunk to determine cardiac index (CI). Measurements were performed at baseline and after a 7 ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in CI > or =15%) and non-responders (increase in CI <15%). Using a threshold dIVC of 18%, responders and non-responders were discriminated with 90% sensitivity and 90% specificity. A strong relation (r = 0.9) was observed between dIVC at baseline and the CI increase following blood volume expansion. Baseline central venous pressure did not accurately predict fluid responsiveness. Our study suggests that respiratory change in IVC diameter is an accurate predictor of fluid responsiveness in septic patients.
                Bookmark

                Author and article information

                Contributors
                +86-15158849975 , hhaijun@126.com
                sqk8511@163.com
                yuansuxia-88@163.com
                xuhua1152@163.com
                hz_fyx@126.com
                Journal
                Crit Care
                Critical Care
                BioMed Central (London )
                1364-8535
                1466-609X
                21 August 2018
                21 August 2018
                2018
                : 22
                : 204
                Affiliations
                ISNI 0000 0004 1799 0055, GRID grid.417400.6, Emergency Department, , The First Affiliated Hospital of Zhejiang Chinese Medical University, ; Zhejiang, 310018 Hangzhou China
                Article
                2063
                10.1186/s13054-018-2063-4
                6102872
                30126449
                ea2e5f0f-3521-4f01-bb3e-7dc439c2e115
                © The Author(s). 2018

                Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License ( http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

                History
                : 19 September 2017
                : 14 May 2018
                Categories
                Research
                Custom metadata
                © The Author(s) 2018

                Emergency medicine & Trauma
                fluid responsiveness,inferior vena cava diameter,mechanical ventilation,meta-analysis

                Comments

                Comment on this article