      Factors affecting accuracy of ventricular volume and ejection fraction measured by gated tl-201 myocardial perfusion single photon emission computed tomography.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The electrocardiogram-gated single photon emission computed tomography (SPECT) measurement of left ventricular end-diastolic volume, end-systolic volume and ejection fraction may contain substantial errors. We evaluated whether patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. Left ventricular volume and ejection fraction were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated end-diastolic and end-systolic volume, and overestimated ejection fraction, but 4D-MSPECT overestimated all those values (P<0.001). Independent variables associated with increasing the difference in end-diastolic volume between echocardiography and gated SPECT were decreasing left ventricular end-diastolic wall thickness, decreasing body surface area, female sex and increasing end-diastolic volume (P<0.001). Those for end-systolic volume were decreasing left ventricular end-systolic wall thickness, female sex, and decreasing end-systolic volume (P<0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in ejection fraction (P<0.001). Adenosine stress SPECT showed significantly higher end-diastolic and end-systolic volume values and a lower ejection fraction than did redistribution SPECT (P<0.001). Patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. Modification of gated SPECT measurements by taking account of these factors would lead to reduce systemic errors.

          Related collections

          Author and article information

          Journal
          Int J Cardiovasc Imaging
          The international journal of cardiovascular imaging
          Springer Nature America, Inc
          1569-5794
          1569-5794
          Oct 2006
          : 22
          : 5
          Affiliations
          [1 ] Department of Nuclear Medicine, University of Ulsan College of Medicine, Seoul, Korea.
          Article
          10.1007/s10554-006-9098-3
          16691365
          ed0ffc70-3255-448e-a5d2-470c9e03190d
          History

          Comments

          Comment on this article