      Tracking myocardial motion from cine DENSE images using spatiotemporal phase unwrapping and temporal fitting.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Displacement encoding with stimulated echoes (DENSE) encodes myocardial tissue displacement into the phase of the MR image. Cine DENSE allows for rapid quantification of myocardial displacement at multiple cardiac phases through the majority of the cardiac cycle. For practical sensitivities to motion, relatively high displacement encoding frequencies are used and phase wrapping typically occurs. In order to obtain absolute measures of displacement, a two-dimensional (2-D) quality-guided phase unwrapping algorithm was adapted to unwrap both spatially and temporally. Both a fully automated algorithm and a faster semi-automated algorithm are proposed. A method for computing the 2-D trajectories of discrete points in the myocardium as they move through the cardiac cycle is introduced. The error in individual displacement measurements is reduced by fitting a time series to sequential displacement measurements along each trajectory. This improvement is in turn reflected in strain maps, which are derived directly from the trajectories. These methods were validated both in vivo and on a rotating phantom. Further measurements were made to optimize the displacement encoding frequency and to estimate the baseline strain noise both on the phantom and in vivo. The fully automated phase unwrapping algorithm was successful for 767 out of 800 images (95.9%), and the semi-automated algorithm was successful for 786 out of 800 images (98.3%). The accuracy of the tracking algorithm for typical cardiac displacements on a rotating phantom is 0.24 +/- 0.15 mm. The optimal displacement encoding frequency is in the region of 0.1 cycles/mm, and, for 2 scans of 17-s duration, the strain noise after temporal fitting was estimated to be 2.5 +/- 3.0% at end-diastole, 3.1 +/- 3.1% at end-systole, and 5.3 +/- 5.0% in mid-diastole. The improvement in intra-myocardial strain measurements due to temporal fitting is apparent in strain histograms, and also in identifying regions of dysfunctional myocardium in studies of patients with infarcts.

          Related collections

          Author and article information

          Journal
          IEEE Trans Med Imaging
          IEEE transactions on medical imaging
          Institute of Electrical and Electronics Engineers (IEEE)
          0278-0062
          0278-0062
          Jan 2007
          : 26
          : 1
          Affiliations
          [1 ] MRC/UCT Medical Imaging Research Unit, University of Cape Town, Cape Town 7925, South Africa. bspotty@gmail.com
          Article
          10.1109/TMI.2006.884215
          17243581
          edc3e6b0-66c7-43b3-a675-898fd43d2f30
          History

          Comments

          Comment on this article