      An Instantaneous Low-Cost Point-of-Care Anemia Detection Device

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We present a small, compact and portable device for point-of-care instantaneous early detection of anemia. The method used is based on direct hematocrit measurement from whole blood samples by means of impedance analysis. This device consists of a custom electronic instrumentation and a plug-and-play disposable sensor. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low consumption device making it completely mobile with a long battery life. Another approach could be powering the system based on other solutions like indoor solar cells, or applying energy-harvesting solutions in order to remove the batteries. The sensing system is based on a disposable low-cost label-free three gold electrode commercial sensor for 50 μL blood samples. The device capability for anemia detection has been validated through 24 blood samples, obtained from four hospitalized patients at Hospital Clínic. As a result, the response, effectiveness and robustness of the portable point-of-care device to detect anemia has been proved with an accuracy error of 2.83% and a mean coefficient of variation of 2.57% without any particular case above 5%.

          Related collections

          Most cited references47

          • Record: found
          • Abstract: found
          • Article: not found

          Biosensor technology: technology push versus market pull.

          Biosensor technology is based on a specific biological recognition element in combination with a transducer for signal processing. Since its inception, biosensors have been expected to play a significant analytical role in medicine, agriculture, food safety, homeland security, environmental and industrial monitoring. However, the commercialization of biosensor technology has significantly lagged behind the research output as reflected by a plethora of publications and patenting activities. The rationale behind the slow and limited technology transfer could be attributed to cost considerations and some key technical barriers. Analytical chemistry has changed considerably, driven by automation, miniaturization, and system integration with high throughput for multiple tasks. Such requirements pose a great challenge in biosensor technology which is often designed to detect one single or a few target analytes. Successful biosensors must be versatile to support interchangeable biorecognition elements, and in addition miniaturization must be feasible to allow automation for parallel sensing with ease of operation at a competitive cost. A significant upfront investment in research and development is a prerequisite in the commercialization of biosensors. The progress in such endeavors is incremental with limited success, thus, the market entry for a new venture is very difficult unless a niche product can be developed with a considerable market volume.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Do blood tests cause anemia in hospitalized patients? The effect of diagnostic phlebotomy on hemoglobin and hematocrit levels.

            To determine whether phlebotomy contributes to changes in hemoglobin and hematocrit levels in hospitalized general internal medicine patients. Retrospective cohort study. General internal medicine inpatient service at a tertiary care hospital. All adult patients discharged from the Toronto General Hospital's internal medicine service between January 1 and June 30, 2001. A total of 989 hospitalizations were reviewed and 404 hospitalizations were included in our analysis. Mean (SD) hemoglobin and hematocrit changes during hospitalization were 7.9 (12.6) g/L (P<.0001) and 2.1% (3.8%) (P<.0001), respectively. The mean (SD) volume of phlebotomy during hospital stay was 74.6 (52.1) mL. On univariate analysis, changes in hemoglobin and hematocrit were predicted by the volume of phlebotomy, length of hospital stay, admission hemoglobin/hematocrit value, age, Charlson comorbidity index, and admission intravascular volume status. The volume of phlebotomy remained a strong predictor of drop in hemoglobin and hematocrit after adjusting for other predictors using multivariate analysis (P<.0001). On average, every 100 mL of phlebotomy was associated with a decrease in hemoglobin and hematocrit of 7.0 g/L and 1.9%, respectively. Phlebotomy is highly associated with changes in hemoglobin and hematocrit levels for patients admitted to an internal medicine service and can contribute to anemia. This anemia, in turn, may have significant consequences, especially for patients with cardiorespiratory diseases. Knowing the expected changes in hemoglobin and hematocrit due to diagnostic phlebotomy will help guide when to investigate anemia in hospitalized patients.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Primary care clinicians’ attitudes towards point-of-care blood testing: a systematic review of qualitative studies

              Background Point-of-care blood tests are becoming increasingly available and could replace current venipuncture and laboratory testing for many commonly used tests. However, at present very few have been implemented in most primary care settings. Understanding the attitudes of primary care clinicians towards these tests may help to identify the barriers and facilitators to their wider adoption. We aimed to systematically review qualitative studies of primary care clinicians’ attitudes to point-of-care blood tests. Methods We systematically searched Medline, Embase, ISI Web of Knowledge, PsycINFO and CINAHL for qualitative studies of primary care clinicians’ attitudes towards point-of-care blood tests in high income countries. We conducted a thematic synthesis of included studies. Results Our search identified seven studies, including around two hundred participants from Europe and Australia. The synthesis generated three main themes: the impact of point-of-care testing on decision-making, diagnosis and treatment; impact on clinical practice more broadly; and impact on patient-clinician relationships and perceived patient experience. Primary care clinicians believed point-of-care testing improved diagnostic certainty, targeting of treatment, self-management of chronic conditions, and clinician-patient communication and relationships. There were concerns about test accuracy, over-reliance on tests, undermining of clinical skills, cost, and limited usefulness. Conclusions We identified several perceived benefits and barriers regarding point-of-care tests in primary care. These imply that if point-of-care tests are to become more widely adopted, primary care clinicians require evidence of their accuracy, rigorous testing of the impact of introduction on patient pathways and clinical practice, and consideration of test funding.
                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel)
                Sensors (Basel, Switzerland)
                MDPI
                1424-8220
                February 2015
                16 February 2015
                : 15
                : 2
                : 4564-4577
                Affiliations
                [1 ] Department of Electronics, University of Barcelona, Martí i Franquès 1, Barcelona 08028, Spain; E-Mails: cpaezaviles@ 123456el.ub.edu (C.P.-A.); ejuanola@ 123456el.ub.edu (E.J.-F.); jcolomer@ 123456el.ub.edu (J.C.-F.); pmiribel@ 123456el.ub.edu (P.L.M.-C.)
                [2 ] Department of Hemotherapy and Hemostasis, CDB, IDIBAPS, Hospital Clínic, Villarroel 170, Barcelona 08036, Spain; E-Mail: jcid@ 123456clinic.ub.es
                [3 ] Centre de Recerca Matemàtica, Campus Bellaterra, UAB, Edifici C, Barcelona 08193, Spain; E-Mail: irodvill@ 123456crm.cat
                Author notes

                Academic Editor: Roberto Pilloton

                [* ] Author to whom correspondence should be addressed; E-Mail: jpunter@ 123456el.ub.es ; Tel.: +34-93-4020876.
                Article
                sensors-15-04564
                10.3390/s150204564
                4367425
                25690552
                ee6e7b9d-aa2b-4a36-a826-40e1e808c89a
                © 2015 by the authors; licensee MDPI, Basel, Switzerland.

                This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 21 November 2014
                : 09 February 2015
                Categories
                Article

                Biomedical engineering
                whole blood,hematocrit,impedance analysis,electronics,point-of-care
                Biomedical engineering
                whole blood, hematocrit, impedance analysis, electronics, point-of-care

                Comments

                Comment on this article