9
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Assessing the role of volumetric‐modulated arc therapy in hepatocellular carcinoma

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The role of volumetric‐modulated arc therapy (VMAT) in hepatocellular carcinoma (HCC) remains controversial. The purpose of this study was to determine the potential clinical role of VMAT compared with three‐dimensional conformal radiotherapy (3D CRT) for liver irradiation. Four‐dimensional CT scans of 24 patients with unresectable HCC were included and divided into two groups: (1) adjacent group ( n = 11 ), with planning target volumes overlapping or within 1 cm adjacent to the alimentary tract; (2) nonadjacent group ( n = 13 ), in which the normal liver itself was the dose‐limiting structure. Target coverage, organs‐at‐risk (OARs) doses, delivery parameters, and treatment accuracy were evaluated. Superior target coverage, conformity, and homogeneity were achieved with VMAT compared with 3D CRT. In the adjacent group, VMAT provided superior sparing of serial functioning OARs including the stomach, small intestine, and spinal cord. In the nonadjacent group, VMAT provided inferior sparing of most OARs including the liver, stomach, and small intestine. For the whole group, the effective treatment time was 2.1 ± 0.3 min for 3D CRT and 3.1 ± 0.2 min for VMAT. For liver lesions adjacent to the alimentary tract, this study indicates that VMAT should be selected due to the plan quality, delivery efficiency, and superior sparing of stomach and small intestine. However, for liver lesions away from the alimentary tract, VMAT is not superior to 3D CRT for normal tissue protection.

          PACS number: 87.55‐x.

          Related collections

          Most cited references27

          • Record: found
          • Abstract: found
          • Article: not found

          Volumetric modulated arc therapy: IMRT in a single gantry arc.

          In this work a novel plan optimization platform is presented where treatment is delivered efficiently and accurately in a single dynamically modulated arc. Improvements in patient care achieved through image-guided positioning and plan adaptation have resulted in an increase in overall treatment times. Intensity-modulated radiation therapy (IMRT) has also increased treatment time by requiring a larger number of beam directions, increased monitor units (MU), and, in the case of tomotherapy, a slice-by-slice delivery. In order to maintain a similar level of patient throughput it will be necessary to increase the efficiency of treatment delivery. The solution proposed here is a novel aperture-based algorithm for treatment plan optimization where dose is delivered during a single gantry arc of up to 360 deg. The technique is similar to tomotherapy in that a full 360 deg of beam directions are available for optimization but is fundamentally different in that the entire dose volume is delivered in a single source rotation. The new technique is referred to as volumetric modulated arc therapy (VMAT). Multileaf collimator (MLC) leaf motion and number of MU per degree of gantry rotation is restricted during the optimization so that gantry rotation speed, leaf translation speed, and dose rate maxima do not excessively limit the delivery efficiency. During planning, investigators model continuous gantry motion by a coarse sampling of static gantry positions and fluence maps or MLC aperture shapes. The technique presented here is unique in that gantry and MLC position sampling is progressively increased throughout the optimization. Using the full gantry range will theoretically provide increased flexibility in generating highly conformal treatment plans. In practice, the additional flexibility is somewhat negated by the additional constraints placed on the amount of MLC leaf motion between gantry samples. A series of studies are performed that characterize the relationship between gantry and MLC sampling, dose modeling accuracy, and optimization time. Results show that gantry angle and MLC sample spacing as low as 1 deg and 0.5 cm, respectively, is desirable for accurate dose modeling. It is also shown that reducing the sample spacing dramatically reduces the ability of the optimization to arrive at a solution. The competing benefits of having small and large sample spacing are mutually realized using the progressive sampling technique described here. Preliminary results show that plans generated with VMAT optimization exhibit dose distributions equivalent or superior to static gantry IMRT. Timing studies have shown that the VMAT technique is well suited for on-line verification and adaptation with delivery times that are reduced to approximately 1.5-3 min for a 200 cGy fraction.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Radiation-associated liver injury.

            The liver is a critically important organ that has numerous functions including the production of bile, metabolism of ingested nutrients, elimination of many waste products, glycogen storage, and plasma protein synthesis. The liver is often incidentally irradiated during radiation therapy (RT) for tumors in the upper- abdomen, right lower lung, distal esophagus, or during whole abdomen or whole body RT. This article describes the endpoints, time-course, and dose-volume effect of radiation on the liver. Published by Elsevier Inc.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Radiation dose-volume effects in the stomach and small bowel.

              Published data suggest that the risk of moderately severe (>or=Grade 3) radiation-induced acute small-bowel toxicity can be predicted with a threshold model whereby for a given dose level, D, if the volume receiving that dose or greater (VD) exceeds a threshold quantity, the risk of toxicity escalates. Estimates of VD depend on the means of structure segmenting (e.g., V15 = 120 cc if individual bowel loops are outlined or V45 = 195 cc if entire peritoneal potential space of bowel is outlined). A similar predictive model of acute toxicity is not available for stomach. Late small-bowel/stomach toxicity is likely related to maximum dose and/or volume threshold parameters qualitatively similar to those related to acute toxicity risk. Concurrent chemotherapy has been associated with a higher risk of acute toxicity, and a history of abdominal surgery has been associated with a higher risk of late toxicity. Copyright 2010 Elsevier Inc. All rights reserved.
                Bookmark

                Author and article information

                Contributors
                liumengzhong@126.com
                Journal
                J Appl Clin Med Phys
                J Appl Clin Med Phys
                10.1002/(ISSN)1526-9914
                ACM2
                Journal of Applied Clinical Medical Physics
                John Wiley and Sons Inc. (Hoboken )
                1526-9914
                06 May 2013
                May 2013
                : 14
                : 3 ( doiID: 10.1002/acm2.2013.14.issue-3 )
                : 81-90
                Affiliations
                [ 1 ] State Key Laboratory of Oncology in Southern China Sun Yat‐sen University Guangzhou China
                [ 2 ] Department of Radiation Oncology, Cancer Center Sun Yat‐sen University Guangzhou China
                [ 3 ] Department of Radiation Oncology The First Affiliated Hospital of Kunming Medical University Kunming China
                Author notes
                [*] [* ] a Corresponding author: Meng‐Zhong Liu, Department of Radiation Oncology, Cancer Center, Sun Yat‐sen University, No.651 Dongfeng East Road, Guangzhou, Guangdong, China; phone: +86‐20‐87343649; fax: +86‐20‐87343649; email: liumengzhong@ 123456126.com

                Article
                ACM20081
                10.1120/jacmp.v14i3.4162
                5714419
                23652248
                f1e22e6b-1aa8-4e04-bd4f-0f4ab9838881
                © 2013 The Authors.

                This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

                History
                : 16 August 2012
                : 17 December 2012
                Page count
                Figures: 3, Tables: 3, References: 27, Pages: 10, Words: 4504
                Categories
                Radiation Oncology Physics
                Radiation Oncology Physics
                Custom metadata
                2.0
                acm20081
                May 2013
                Converter:WILEY_ML3GV2_TO_NLMPMC version:5.2.5 mode:remove_FC converted:16.11.2017

                hepatocellular carcinoma,volumetric‐modulated arc therapy,three‐dimensional conformal radiotherapy,dosimetry