          This study assessed the effect of prolonged left ventricular unloading on native ventricular function. We reviewed data from 31 patients (30 men, 1 woman) supported more than 30 days (mean, 137 days; range, 31 to 505 days) with the HeartMate left ventricular assist system. The patients' mean age was 46 years (range, 22 to 64 years); 17 had idiopathic and 14 had ischemic cardiomyopathy. Data (anatomic, physiologic, hemodynamic, histologic, and biochemical) were collected at the time of HeartMate implantation, during support with the device temporarily off, and at the time of device explantation. Routine chest roentgenogram showed improvement in cardiothoracic ratio (0.62 +/- 0.04 to 0.55 +/- 0.03; p < 0.0001). Echocardiography performed with the pump off showed a significant decrease in left ventricular end-diastolic dimension (6.81 +/- 0.87 cm to 5.39 +/- 1.08 cm; p < 0.0005) and a significant improvement in ejection fraction (0.11 +/- 0.05 to 0.22 +/- 0.17; p < 0.02). Cardiac index increased (1.96 +/- 0.52 L.min-1.m-2 to 2.93 +/- 0.73 L.min-1.m-2; p < 0.0001), mean aortic pressure increased (71.40 +/- 10.63 mm Hg to 76.33 +/- 16.84 mm Hg; p = 0.48), pulmonary capillary wedge pressure decreased (24.18 +/- 6.27 mm Hg to 14.48 +/- 3.01 mm Hg; p < 0.0001), and pulmonary vascular resistance decreased (3.34 +/- 2.00 Wood units to 2.51 +/- 0.88 Wood units; p < 0.05). Comparisons of tissue samples taken at the time of implantation and at the time of transplantation showed a marked reduction in myocytolysis. Calcium uptake, calcium-binding rates, and lipid levels normalized in patients studied. Plasma norepinephrine levels decreased to near normal levels. Prospective studies are now indicated to determine whether device removal without transplantation may be beneficial in selected patients.

          Related collections

          Author and article information

          Journal
          The Annals of Thoracic Surgery
          The Annals of Thoracic Surgery
          Elsevier BV
          00034975
          August 1996
          August 1996
          : 62
          : 3
          : 675-682
          Article
          10.1016/S0003-4975(96)00437-7
          8783992
          f2a0969c-e145-4c88-bdc2-704801d03446
          © 1996

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article