      Hearing Instruments for Unilateral Severe-to-Profound Sensorineural Hearing Loss in Adults: A Systematic Review and Meta-Analysis

      research-article

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objectives:

          A systematic review of the literature and meta-analysis was conducted to assess the nature and quality of the evidence for the use of hearing instruments in adults with a unilateral severe to profound sensorineural hearing loss.

          Design:

          The PubMed, EMBASE, MEDLINE, Cochrane, CINAHL, and DARE databases were searched with no restrictions on language. The search included articles from the start of each database until February 11, 2015. Studies were included that (a) assessed the impact of any form of hearing instrument, including devices that reroute signals between the ears or restore aspects of hearing to a deaf ear, in adults with a sensorineural severe to profound loss in one ear and normal or near-normal hearing in the other ear; (b) compared different devices or compared a device with placebo or the unaided condition; (c) measured outcomes in terms of speech perception, spatial listening, or quality of life; (d) were prospective controlled or observational studies. Studies that met prospectively defined criteria were subjected to random effects meta-analyses.

          Results:

          Twenty-seven studies reported in 30 articles were included. The evidence was graded as low-to-moderate quality having been obtained primarily from observational before-after comparisons. The meta-analysis identified statistically significant benefits to speech perception in noise for devices that rerouted the speech signals of interest from the worse ear to the better ear using either air or bone conduction (mean benefit, 2.5 dB). However, these devices also degraded speech understanding significantly and to a similar extent (mean deficit, 3.1 dB) when noise was rerouted to the better ear. Data on the effects of cochlear implantation on speech perception could not be pooled as the prospectively defined criteria for meta-analysis were not met. Inconsistency in the assessment of outcomes relating to sound localization also precluded the synthesis of evidence across studies. Evidence for the relative efficacy of different devices was sparse but a statistically significant advantage was observed for rerouting speech signals using abutment-mounted bone conduction devices when compared with outcomes after preoperative trials of air conduction devices when speech and noise were colocated (mean benefit, 1.5 dB). Patients reported significant improvements in hearing-related quality of life with both rerouting devices and following cochlear implantation. Only two studies measured health-related quality of life and findings were inconclusive.

          Conclusions:

          Devices that reroute sounds from an ear with a severe to profound hearing loss to an ear with minimal hearing loss may improve speech perception in noise when signals of interest are located toward the impaired ear. However, the same device may also degrade speech perception as all signals are rerouted indiscriminately, including noise. Although the restoration of functional hearing in both ears through cochlear implantation could be expected to provide benefits to speech perception, the inability to synthesize evidence across existing studies means that such a conclusion cannot yet be made. For the same reason, it remains unclear whether cochlear implantation can improve the ability to localize sounds despite restoring bilateral input. Prospective controlled studies that measure outcomes consistently and control for selection and observation biases are required to improve the quality of the evidence for the provision of hearing instruments to patients with unilateral deafness and to support any future recommendations for the clinical management of these patients.

          Abstract

          Adults with a unilateral severe-to-profound sensorineural hearing loss report difficulties with listening in many everyday situations. Current hearing instruments attempt to alleviate these difficulties either by rerouting sounds from the impaired ear to the non-impaired ear or by restoring hearing in the impaired ear. A systematic review and meta-analysis evaluated the evidence for their use. The evidence was of low-to-moderate quality. Meta-analyses found benefits to speech perception in noise and reductions in listening difficulty. Controlled trials are needed to provide higher-quality evidence for hearing instrument use in unilateral deafness and to support recommendations for the clinical management of these patients.

          Supplemental Digital Content is available in the text.

          Related collections

          Most cited references59

          • Record: found
          • Abstract: not found
          • Article: not found

          The hazards of scoring the quality of clinical trials for meta-analysis.

          Although it is widely recommended that clinical trials undergo some type of quality review, the number and variety of quality assessment scales that exist make it unclear how to achieve the best assessment. To determine whether the type of quality assessment scale used affects the conclusions of meta-analytic studies. Meta-analysis of 17 trials comparing low-molecular-weight heparin (LMWH) with standard heparin for prevention of postoperative thrombosis using 25 different scales to identify high-quality trials. The association between treatment effect and summary scores and the association with 3 key domains (concealment of treatment allocation, blinding of outcome assessment, and handling of withdrawals) were examined in regression models. Pooled relative risks of deep vein thrombosis with LMWH vs standard heparin in high-quality vs low-quality trials as determined by 25 quality scales. Pooled relative risks from high-quality trials ranged from 0.63 (95% confidence interval [CI], 0.44-0.90) to 0.90 (95% CI, 0.67-1.21) vs 0.52 (95% CI, 0.24-1.09) to 1.13 (95% CI, 0.70-1.82) for low-quality trials. For 6 scales, relative risks of high-quality trials were close to unity, indicating that LMWH was not significantly superior to standard heparin, whereas low-quality trials showed better protection with LMWH (P<.05). Seven scales showed the opposite: high quality trials showed an effect whereas low quality trials did not. For the remaining 12 scales, effect estimates were similar in the 2 quality strata. In regression analysis, summary quality scores were not significantly associated with treatment effects. There was no significant association of treatment effects with allocation concealment and handling of withdrawals. Open outcome assessment, however, influenced effect size with the effect of LMWH, on average, being exaggerated by 35% (95% CI, 1%-57%; P= .046). Our data indicate that the use of summary scores to identify trials of high quality is problematic. Relevant methodological aspects should be assessed individually and their influence on effect sizes explored.
            • Record: found
            • Abstract: found
            • Article: not found

            Development of the Hearing in Noise Test for the measurement of speech reception thresholds in quiet and in noise.

            A large set of sentence materials, chosen for their uniformity in length and representation of natural speech, has been developed for the measurement of sentence speech reception thresholds (sSRTs). The mean-squared level of each digitally recorded sentence was adjusted to equate intelligibility when presented in spectrally matched noise to normal-hearing listeners. These materials were cast into 25 phonemically balanced lists of ten sentences for adaptive measurement of sentence sSRTs. The 95% confidence interval for these measurements is +/- 2.98 dB for sSRTs in quiet and +/- 2.41 dB for sSRTs in noise, as defined by the variability of repeated measures with different lists. Average sSRTs in quiet were 23.91 dB(A). Average sSRTs in 72 dB(A) noise were 69.08 dB(A), or -2.92 dB signal/noise ratio. Low-pass filtering increased sSRTs slightly in quiet and noise as the 4- and 8-kHz octave bands were eliminated. Much larger increases in SRT occurred when the 2-kHz octave band was eliminated, and bandwidth dropped below 2.5 kHz. Reliability was not degraded substantially until bandwidth dropped below 2.5 kHz. The statistical reliability and efficiency of the test suit it to practical applications in which measures of speech intelligibility are required.
              • Record: found
              • Abstract: found
              • Article: not found

              Comparison of pseudobinaural hearing to real binaural hearing rehabilitation after cochlear implantation in patients with unilateral deafness and tinnitus.

              Up to now, treatment modalities of unilateral deafness consist of no treatment, conventional contralateral routing of signal (CROS), or Bone-Anchored Hearing Aid (BAHA) hearing aid. Cochlear implantation makes a new treatment modality available for patients with single-sided deafness. The aim of this study is to evaluate the use of unilateral electrical stimulation with normal hearing on the contralateral side after a period of 6 months compared with the preoperative unaided situation, conventional CROS, or BAHA hearing aids. Prospective design. Tertiary referral center; cochlear implant (CI) program. Eleven adult subjects with unilateral deafness of various causes were enrolled in the study. Only those patients were included in whom therapy with CROS hearing aid or BAHA was not successful and in whom the auditory nerve was found to be intact and the cochlea patent for cochlear implantation. All subjects were fitted in random order with a BAHA Intenso mounted on the softband/tension clamp or with a CROS hearing aid. After test periods with both devices, the subjects received a CI. The Hochmair-Schulz-Moser sentence test and the Oldenburg sentence test were used to test speech comprehension in 3 presentation configurations in the unaided situation, with conventional CROS and BAHA hearing aids before cochlear implantation as well as after 6 months with CI. Localization was assessed using an array of 7 speakers at head level in a frontal semicircle. Subjective improvement in daily life was evaluated using the Speech, Spatial and Qualities of Hearing Scale, the Health Utilities Index 3 and the International Outcome Inventory for Hearing Aids questionnaires. Tinnitus distress was measured with a tinnitus scale before and after CI implantation. The results show significant improvement in localization ability as well as in speech comprehension in most presentation configurations with the CI. Especially, there is no negative effect on speech comprehension if the noise is presented to the CI ear and speech to the normal hearing ear. With the CI, the summation and squelch effects are not significant, but a significant combined head shadow effect is seen. Speech, Spatial and Qualities of Hearing results show an overall benefit of wearing the CI compared with the other treatment options. The tinnitus scale revealed a positive effect of CI stimulation in cases of preoperative tinnitus. The results in these patients suggest that cochlear implantation improves hearing abilities in people with single-sided deafness and is superior to the alternative treatment options. The use of the CI does not interfere with speech understanding in the normal hearing ear. Our data suggest that the binaural integration of electric and acoustic stimulation is possible even with unilateral normal hearing.

                Author and article information

                Journal
                Ear Hear
                Ear Hear
                AUD
                Ear and Hearing
                Williams And Wilkins
                0196-0202
                1538-4667
                September 2016
                26 August 2016
                : 37
                : 5
                : 495-507
                Affiliations
                [1 ]National Institute for Health Research Nottingham Hearing Biomedical Research Unit, The Ropewalk, Nottingham, United Kingdom; and [2 ]Otology and Hearing Group, Division of Clinical Neuroscience, School of Medicine, University of Nottingham, Nottingham, United Kingdom.
                Author notes
                Address for correspondence: Pádraig Thomas Kitterick, National Institute for Health Research Nottingham Hearing Biomedical Research Unit, Ropewalk House, 113 The Ropewalk, Nottingham, NG1 5DU, United Kingdom. E-mail: padraig.kitterick@ 123456nottingham.ac.uk
                Article
                00001
                10.1097/AUD.0000000000000313
                4998125
                27232073
                f3058ca3-e578-4eca-8275-ec2e8a9e6ebd
                Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved

                This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially.

                History
                : 12 April 2015
                : 28 February 2016
                Categories
                Systematic Review and Meta-Analysis
                Custom metadata
                TRUE
                T

                air conduction,bone conduction,cochlear implantation,contralateral routing of signals,localization,meta-analysis,quality of life,re-routing devices,restorative devices,single-sided deafness,speech perception,systematic review,unilateral deafness,unilateral hearing loss

                Comments

                Comment on this article

                Related Documents Log