14
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Clinical evaluation of rapid fluorescent diagnostic immunochromatographic test for influenza A virus (H1N1)

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Rapid diagnostic tests (RDTs) have been developed to detect influenza A virus for the swift diagnosis and management of patients. However, despite the simplicity and convenience, the low sensitivity of RDTs remains a limitation for their use in point of care testing (POCT). In this study, we developed a rapid fluorescent immunochromatographic strip test (FICT) and the performance of FICT was confirmed by the real-time reverse transcription-polymerase chain reaction (rRT-PCR) of H1N1, compared with that of RDT. The limit of detection (LOD) of FICT was improved by 16-fold compared to RDT. FICT showed 85.29% sensitivity (29/34) (95% Confidence Interval [95% CI]: 68.94 to 95.05), 100% specificity (26/26) (95% CI: 86.78 to 100.00), and a strong correlation (kappa; 0. 92) compared with rRT-PCR (20 ≤ Ct ≤ 36). In contrast, RDT (Standard Diagnostics [SD] BIOLINE Influenza Ag A/ B/ A(H1N1) Pandemic) showed 55.88% sensitivity (19/34) (95% CI: 37.87 to 72.82), 100% specificity (26/26) (95% CI: 77.07 to 100), and had a fair correlation with rRT-PCR (kappa; 0. 75). FICT had better sensitivity than RDT ( P < 0.01; McNemar’s test). Therefore, FICT has the potential to improve the quality of current rapid POCT for the diagnosis of influenza A/H1N1 infection.

          Related collections

          Most cited references18

          • Record: found
          • Abstract: found
          • Article: not found

          Limit of blank, limit of detection and limit of quantitation.

          * Limit of Blank (LoB), Limit of Detection (LoD), and Limit of Quantitation (LoQ) are terms used to describe the smallest concentration of a measurand that can be reliably measured by an analytical procedure. * LoB is the highest apparent analyte concentration expected to be found when replicates of a blank sample containing no analyte are tested. LoB = mean(blank) + 1.645(SD(blank)). * LoD is the lowest analyte concentration likely to be reliably distinguished from the LoB and at which detection is feasible. LoD is determined by utilising both the measured LoB and test replicates of a sample known to contain a low concentration of analyte. * LoD = LoB + 1.645(SD (low concentration sample)). * LoQ is the lowest concentration at which the analyte can not only be reliably detected but at which some predefined goals for bias and imprecision are met. The LoQ may be equivalent to the LoD or it could be at a much higher concentration.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The Diagnosis of Viral Respiratory Disease in Older Adults

            Abstract Viral respiratory disease in older adults has been increasingly recognized as a significant cause of hospitalizations and death. Unfortunately, the recognition and diagnosis of infection due to many viral respiratory pathogens in older adults can be elusive because of atypical clinical presentations and the insensitivity of current laboratory diagnostic tests in this population. For influenza diagnosis, rapid antigen tests followed by viral culture (if antigen test results are negative), can be useful in older adults as long as clinicians are mindful of test limitations. Although specific, rapid antigen tests are insensitive in this population. Erroneous negative results may lead to delays in timely administration of antiviral treatment and institution of appropriate isolation precautions. The increasing availability of new, rapid, and sensitive molecular diagnostics, such as polymerase chain reaction testing, should provide more accurate and timely diagnoses of viral respiratory infections in older adults in the near future.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Amine coupling through EDC/NHS: a practical approach.

              Surface plasmon resonance (SPR) is one of the leading tools in biomedical research. The challenge in its use is the controlled positioning of one of the components of an interaction on a carefully designed surface. Many attempts in interaction analysis fail due to the non-functional or unsuccessful immobilization of a reactant onto the complex matrix of that surface. The most common technique for linking ligands covalently to a hydrophilic solid surface is amine coupling via reactive esters. In this chapter detailed methods and problem discussions will be given to assist in fast decision analysis to optimize immobilization and regeneration. Topics in focus are different coupling techniques for small and large molecules, streptavidin-biotin sandwich immobilization, and optimizing regeneration conditions.
                Bookmark

                Author and article information

                Contributors
                yeosj@wku.ac.kr
                Journal
                Sci Rep
                Sci Rep
                Scientific Reports
                Nature Publishing Group UK (London )
                2045-2322
                7 September 2018
                7 September 2018
                2018
                : 8
                : 13468
                Affiliations
                [1 ]ISNI 0000 0004 0533 4755, GRID grid.410899.d, Department of Pediatrics, School of Medicine, , Wonkwang University, ; 460, Iksan-daero, Iksan, 54538 Republic of Korea
                [2 ]ISNI 0000 0004 0533 4755, GRID grid.410899.d, Zoonosis Research Center, Department of Infection Biology, School of Medicine, , Wonkwang University, ; Iksan, 570-749 Republic of Korea
                Author information
                http://orcid.org/0000-0002-9422-187X
                Article
                31786
                10.1038/s41598-018-31786-8
                6128899
                30194330
                f36e6105-6735-4f56-aa32-13be6618a2ce
                © The Author(s) 2018

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 15 August 2017
                : 12 August 2018
                Funding
                Funded by: This research was supported by Priority Research Centers Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Education, (NRF-2015R1A6A1A03032236).&amp;#x2003;
                Funded by: FundRef https://doi.org/10.13039/501100003725, National Research Foundation of Korea (NRF);
                Award ID: NRF-2015R1A6A1A03032236
                Award Recipient :
                Categories
                Article
                Custom metadata
                © The Author(s) 2018

                Uncategorized
                Uncategorized

                Comments

                Comment on this article