      Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser

      , , , ,
      Optics Express
      The Optical Society

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We demonstrate ultrahigh speed swept source retinal OCT imaging using a Fourier domain mode locked (FDML) laser. The laser uses a combination of a semiconductor optical amplifier and an ytterbium doped fiber amplifier to provide more than 50 mW output power. The 1050 nm FDML laser uses standard telecom fiber for the km long delay line instead of two orders of magnitude more expensive real single mode fiber. We investigate the influence of this "oligo-mode" fiber on the FDML laser performance. Two design configurations with 684,400 and 1,368,700 axial scans per second are investigated, 25x and 50x faster than current commercial instruments and more than 4x faster than previous single spot ophthalmic results. These high speeds enable the acquisition of densely sampled ultrawide-field data sets of the retina within a few seconds. Ultrawide-field data consisting of 1900 x 1900 A-scans with ~70° angle of view are acquired within only 3 and 6 seconds using the different setups. Such OCT data sets, more than double as large as previously reported, are collapsed to a 4 megapixel high definition fundus image. We achieve good penetration into the choroid by hardware spectral shaping of the laser output. The axial resolution in tissue is 12 µm (684 kHz) and 19 µm (1.37 MHz). A series of new data processing and imaging extraction protocols, enabled by the ultrawide-field isotropic data sets, are presented. Dense isotropic sampling enables both, cross-sectional images along arbitrary coordinates and depth-resolved en-face fundus images. Additionally, we investigate how isotropic averaging compares to the averaging of cross-sections along the slow axis.

          Related collections

          Most cited references58

          • Record: found
          • Abstract: found
          • Article: not found

          Weakly guiding fibers.

          D Gloge (1971)
          Thin glass fibers imbedded into a glass cladding of slightly lower refractive index represent a promising medium for optical communication. This article presents simple formulas and functions for the fiber parameters as a help for practical design work. It considers the propagation constant, mode delay, the cladding field depth, and the power distribution in the fiber cross section. Plots vs frequency of these parameters are given for 70 modes.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation.

            Ultrahigh-resolution optical coherence tomography uses broadband light sources to achieve axial image resolutions on the few micron scale. Fourier domain detection methods enable more than an order of magnitude increase in imaging speed and sensitivity, thus overcoming the sensitivity limitations inherent in ultrahigh-resolution OCT using standard time domain detection. Fourier domain methods also provide direct access to the spectrum of the optical signal. This enables automatic numerical dispersion compensation, a key factor in achieving ultrahigh image resolutions. We present ultrahigh-resolution, high-speed Fourier domain OCT imaging with an axial resolution of 2.1 ìm in tissue and 16,000 axial scans per second at 1024 pixels per axial scan. Ultrahigh-resolution spectral domain OCT is shown to provide a ~100x increase in imaging speed when compared to ultrahigh-resolution time domain OCT. In vivo imaging of the human retina is demonstrated. We also present a general technique for automatic numerical dispersion compensation, which is applicable to spectral domain as well as swept source embodiments of Fourier domain OCT.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              In vivo retinal imaging by optical coherence tomography.

              We describe what are to our knowledge the first in vivo measurements of human retinal structure with optical coherence tomography. These images represent the highest depth resolution in vivo retinal images to date. The tomographic system, image-processing techniques, and examples of high-resolution tomographs and their clinical relevance are discussed.
                Bookmark

                Author and article information

                Journal
                OPEXFF
                Optics Express
                Opt. Express
                The Optical Society
                1094-4087
                2011
                2011
                February 02 2011
                February 14 2011
                : 19
                : 4
                : 3044
                Article
                10.1364/OE.19.003044
                21369128
                f460c137-b27b-46ec-99e4-c95148a442b6
                © 2011
                History

                Molecular medicine,Neurosciences
                Molecular medicine, Neurosciences

                Comments

                Comment on this article