      Safety and Effectiveness of a Novel Fluoroless Transseptal Puncture Technique for Lead-free Catheter Ablation: A Case Series

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Increasing awareness of the health risks associated with the exposure of patients and staff in the catheterization laboratory to radiation has encouraged the pursuit of efforts to reduce the use of fluoroscopy during catheter ablation procedures. Although nonfluoroscopic guidance of ablation catheters has been previously described, transseptal access is still perceived as the last remaining barrier to completely fluoroless ablations. This study examined the safety and effectiveness of transseptal puncture and radiofrequency (RF) catheter ablation using a completely fluoroless approach. Three hundred eighty-two consecutive cases that had undergone completely nonfluoroscopic RF catheter ablation were evaluated. Ablation procedures were performed for atrial fibrillation, atrial flutter, atrioventricular reentry tachycardia, and pulmonary vein complex/ventricular tachycardia. Transseptal puncture and RF ablation were conducted under three-dimensional electroanatomic mapping and intracardiac echocardiography image guidance. Fluoroless transseptal puncture and catheter ablation were completed successfully in all cases, with no intraoperative complications. One patient required minimal use of fluoroscopy to visualize sheath advancement through an existing inferior vena cava filter. Procedural time was approximately 2.2 hours from transvenous access until case conclusion; transseptal access was obtained within 28 minutes of procedure initiation. Arrhythmia was found to recur in 27% of cases on average three months after the procedure. We demonstrate the safety and effectiveness of a completely fluoroless transseptal puncture and RF ablation technique that eliminates radiation exposure and enables complex electrophysiology procedures to be performed in a lead-free environment.

          Related collections

          Most cited references33

          • Record: found
          • Abstract: found
          • Article: not found

          Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources--1950-2007.

          The U.S. National Council on Radiation Protection and Measurements and United Nations Scientific Committee on Effects of Atomic Radiation each conducted respective assessments of all radiation sources in the United States and worldwide. The goal of this article is to summarize and combine the results of these two publicly available surveys and to compare the results with historical information. In the United States in 2006, about 377 million diagnostic and interventional radiologic examinations and 18 million nuclear medicine examinations were performed. The United States accounts for about 12% of radiologic procedures and about one-half of nuclear medicine procedures performed worldwide. In the United States, the frequency of diagnostic radiologic examinations has increased almost 10-fold (1950-2006). The U.S. per-capita annual effective dose from medical procedures has increased about sixfold (0.5 mSv [1980] to 3.0 mSv [2006]). Worldwide estimates for 2000-2007 indicate that 3.6 billion medical procedures with ionizing radiation (3.1 billion diagnostic radiologic, 0.5 billion dental, and 37 million nuclear medicine examinations) are performed annually. Worldwide, the average annual per-capita effective dose from medicine (about 0.6 mSv of the total 3.0 mSv received from all sources) has approximately doubled in the past 10-15 years. (c) RSNA, 2009.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Brain and neck tumors among physicians performing interventional procedures.

            Physicians performing interventional procedures are chronically exposed to ionizing radiation, which is known to pose increased cancer risks. We recently reported 9 cases of brain cancer in interventional cardiologists. Subsequently, we received 22 additional cases from around the world, comprising an expanded 31 case cohort. Data were transmitted to us during the past few months. For all cases, where possible, we endeavored to obtain the baseline data, including age, gender, tumor type, and side involved, specialty (cardiologist vs radiologist), and number of years in practice. These data were obtained from the medical records, interviews with patients, when possible, or with family members and/or colleagues. The present report documented brain and neck tumors occurring in 31 physicians: 23 interventional cardiologists, 2 electrophysiologists, and 6 interventional radiologists. All physicians had worked for prolonged periods (latency period 12 to 32 years, mean 23.5 ± 5.9) in active interventional practice with exposure to ionizing radiation in the catheterization laboratory. The tumors included 17 cases (55%) of glioblastoma multiforme (GBM), 2 astrocytomas (7%), and 5 meningiomas (16%). In 26 of 31 cases, data were available regarding the side of the brain involved. The malignancy was left sided in 22 (85%), midline in 1, and right sided in 3 operators. In conclusion, these results raise additional concerns regarding brain cancer developing in physicians performing interventional procedures. Given that the brain is relatively unprotected and the left side of the head is known to be more exposed to radiation than the right, these findings of disproportionate reports of left-sided tumors suggest the possibility of a causal relation to occupational radiation exposure.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Ionizing radiation in cardiac imaging: a science advisory from the American Heart Association Committee on Cardiac Imaging of the Council on Clinical Cardiology and Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention.

                Bookmark

                Author and article information

                Journal
                J Innov Card Rhythm Manag
                J Innov Card Rhythm Manag
                JICRM
                The Journal of Innovations in Cardiac Rhythm Management
                MediaSphere Medical (United States )
                2156-3977
                2156-3993
                15 April 2020
                April 2020
                : 11
                : 4
                : 4079-4085
                Affiliations
                [1] 1Pulse Heart Institute, MultiCare Health System, Tacoma, WA, USA
                Author notes
                Address correspondence to: Tariq Salam, MD, FHRS, Pulse Heart Institute, MultiCare Health System, 1901 S. Cedar St, Suite 301, Tacoma, WA 98405, USA. Email: tsalam@ 123456multicare.org .

                The authors report no conflicts of interest for the published content. This work did not receive external financial support and was funded by an ongoing internal quality improvement initiative at the Pulse Heart Institute.

                Article
                icrm.2020.110405
                10.19102/icrm.2020.110405
                7192152
                32368383
                f622aec9-db37-4c43-a677-eed16fd82b78
                Copyright: © 2020 Innovations in Cardiac Rhythm Management

                This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 04 September 2019
                : 28 October 2019
                Categories
                Original Research

                atrial fibrillation,catheter ablation,electroanatomic mapping,fluoroless,transseptal puncture

                Comments

                Comment on this article