2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      A Simple Protocol to Prevent External Ventricular Drain Infections :

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          External ventricular drains (EVDs) are associated with high rates of infection, and EVD infections cause substantial morbidity and mortality.

          Related collections

          Most cited references14

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Sustaining reductions in catheter related bloodstream infections in Michigan intensive care units: observational study

          Objectives To evaluate the extent to which intensive care units participating in the initial Keystone ICU project sustained reductions in rates of catheter related bloodstream infections. Design Collaborative cohort study to implement and evaluate interventions to improve patients’ safety. Setting Intensive care units predominantly in Michigan, USA. Intervention Conceptual model aimed at improving clinicians’ use of five evidence based recommendations to reduce rates of catheter related bloodstream infections rates, with measurement and feedback of infection rates. During the sustainability period, intensive care unit teams were instructed to integrate this intervention into staff orientation, collect monthly data from hospital infection control staff, and report infection rates to appropriate stakeholders. Main outcome measures Quarterly rate of catheter related bloodstream infections per 1000 catheter days during the sustainability period (19-36 months after implementation of the intervention). Results Ninety (87%) of the original 103 intensive care units participated, reporting 1532 intensive care unit months of data and 300 310 catheter days during the sustainability period. The mean and median rates of catheter related bloodstream infection decreased from 7.7 and 2.7 (interquartile range 0.6-4.8) at baseline to 1.3 and 0 (0-2.4) at 16-18 months and to 1.1 and 0 (0.0-1.2) at 34-36 months post-implementation. Multilevel regression analysis showed that incidence rate ratios decreased from 0.68 (95% confidence interval 0.53 to 0.88) at 0-3 months to 0.38 (0.26 to 0.56) at 16-18 months and 0.34 (0.24-0.48) at 34-36 months post-implementation. During the sustainability period, the mean bloodstream infection rate did not significantly change from the initial 18 month post-implementation period (−1%, 95% confidence interval −9% to 7%). Conclusions The reduced rates of catheter related bloodstream infection achieved in the initial 18 month post-implementation period were sustained for an additional 18 months as participating intensive care units integrated the intervention into practice. Broad use of this intervention with achievement of similar results could substantially reduce the morbidity and costs associated with catheter related bloodstream infections.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Nosocomial ventriculitis and meningitis in neurocritical care patients.

            External ventricular drainage (EVD) is frequently necessary in neurological and neurosurgical intensive care patients. A major complication of this procedure is an EVD-related venticulitis or meningitis. The purpose of this review is (1) to address the magnitude of the problem in the neurocritical care patient population, (2) to discuss the difficulties in providing an appropriate and timely diagnosis of this disease entity and (3) to propose an algorithm for both rapid diagnosis and appropriate therapy. A MEDLINE literature search was carried out for studies from January 1990 through March 2008 reporting on ventriculostomy, EVD-related central nervous system infections, in particular ventriculitis and meningitis. EVD-related ventriculitis is a serious nosocomial complication in the neurocritical care setting where EVD catheters are frequently used for the management of elevated ICP secondary to acute hydrocephalus primarily caused by subarachnoid and intraventricular hemorrhage or traumatic brain injury. Infection rate is high with reported incidences in the range of 5 % up to more than 20 %. Predisposing factors for infection are non-adherence to rigid insertion and maintenance protocols, leakage of cerebrospinal fluid (CSF), catheter irrigation and the frequency of EVD manipulation. Diagnosis is frequently impaired either by the presence of systemic inflammation due to the primary disease or because the hemorrhagic CSF itself may cause an inflammatory reaction. Furthermore, the most common pathogens involved in EVD-related infections, i. e., staphylococci, initially provoke only a mild inflammatory response in the CSF and therefore patients rarely present with clear-cut clinical signs indicating severe central nervous system infection, in particular, ventriculitis. Nosocomial EVD-related ventriculitis is a significant cause of morbidity and mortality in critically ill neurological patients. Rapid diagnosis and prompt initiation of appropriate antimicrobial therapy is needed. A stepwise algorithm for the management of EVD-related ventriculitis is proposed.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Efficacy of antimicrobial-impregnated external ventricular drain catheters: a prospective, randomized, controlled trial.

              Catheter-related infection of the cerebrospinal fluid (CSF) pathways is a potentially life-threatening complication of external ventricular drainage. A major source of infection is bacterial contamination along the external ventricular drain (EVD) catheter track. The authors examined the efficacy of EVD catheters impregnated with minocycline and rifampin in preventing these catheter-related infections. The authors conducted a prospective, randomized clinical trial at six academic medical centers. All hospitalized patients 18 years or older who required placement of an EVD catheter were eligible for inclusion in the study. Patients were randomly assigned to undergo placement of an EVD with a catheter impregnated with minocycline and rifampin or a standard untreated catheter (control group). To assess primary outcome, CSF samples were collected using a sterile technique at the time of catheter insertion, at least every 72 hours while the catheter remained in place, and at the time of catheter removal. At the time of removal, CSF cultures were obtained from the tip and tunneled segments of each catheter by performing semiquantitative roll-plate and quantitative sonication techniques. Of the 306 patients enrolled in the study, data from 288 were included in the final analysis. Eighteen patients were excluded from analysis: 14 because the ventricular catheter was in place less than 24 hours, and four because CSF cultures obtained at the time of catheter insertion were positive for infection. Of these 288 patients, 139 were assigned to the control group and 149 to the treatment group. The two groups were well matched with respect to all clinical characteristics, including patient sex and mean age, indication for catheter placement, and length of time the catheter remained in place. The antibiotic-impregnated catheters were one half as likely to become colonized as the control catheters (17.9 compared with 36.7%, respectively, p < 0.0012). Positive CSF cultures were seven times less frequent in patients with antibiotic-impregnated catheters compared with those in the control group (1.3 compared with 9.4%, respectively, p = 0.002). The use of EVD catheters impregnated with minocycline and rifampin can significantly reduce the risk of catheter-related infections.
                Bookmark

                Author and article information

                Journal
                Neurosurgery
                Neurosurgery
                Ovid Technologies (Wolters Kluwer Health)
                0148-396X
                2013
                June 2013
                : 72
                : 6
                : 993-999
                Article
                10.1227/NEU.0b013e31828e8dfd
                23467249
                f63a3ae4-5cd9-4805-8d8d-076baca97f7a
                © 2013
                History

                Comments

                Comment on this article