Selecting better diagnostic kits for diagnosis of malarial parasites at point of care.

Read this article at

ScienceOpenPublisherPMC
Bookmark
      There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

      Abstract

      Malaria is a fatal life-threatening parasitic infection and a leading cause of morbidity and mortality. The present study was aimed to evaluate simple, inexpensive, accurate, reliable, easily available better diagnostic for rapid detection of malaria at point of care (POC). The study includes 1403 samples collected from the patients, of which 1227 were clinically suspected cases and 176 from consecutive feverish patients. Among the suspected cases only 338 samples were confirmed positive and 889 samples were negative for Plasmodium species by PCR. All the 889 samples showed negative result for plasmodium species by microscopy, Malarial Ag rapid kits but only 867 samples were confirmed negative with malarial Ab rapid kits. Of the 338 PCR positive samples, 337 samples were confirmed positive by microscopy and Malarial Ag rapid kits, but only 284 samples were confirmed positive using malarial Ab rapid kits. Overall the microscopy and the malaria antigen-based lateral flow assay exhibited similar sensitivity, specificity, PPV, NPV and efficiency, respectively, whereas the PCR assay had 100% sensitivity, specificity, PPV, NPV and efficiency. But the evolutionary data for malaria antibody lateral flow assay has 92.81% sensitivity, 94.13% specificity, 84.02% PPV, 97.52% NPV and 93.80% efficiency. The developed Malaria pf/pv antigen and antibody field-deployable kits are simple, rapid, accurate, reliable, inexpensive, user friendly, POC. In addition the kits are highly sensitive and species-specific. The pf/pv antigen kit is found to be more accurate with 99.7% sensitivity and 100% specificity than to Malaria pf/pv antibody rapid kits. Of the two rapid kits developed, Malaria pf/pv antigen kit is found be more accurate with 99.7% sensitivity and 100% specificity than to Malaria pf/pv antibody rapid kits.

      Related collections

      Author and article information

      Affiliations
      [1] 1Department of Biotechnology, Acharya Nagarjuna University, Guntur, Andhra Pradesh India.
      [2] Genomix Molecular Diagnostics Pvt. Ltd, 5-36/207, Prashanthinagar, Kukatpally, Hyderabad, Andhra Pradesh 500072 India.
      [3] Department of Clinical Microbiology, Malla Reddy Institute of Medical Sciences, Suraram, Hyderabad, Andhra Pradesh India.
      [4] 3Department of Clinical Biochemistry, MNR Medical College and Hospital, Sangareddy, India.
      [5] 5Department of Botany and Microbiology, Acharya Nagarjuna University, Guntur, Andhra Pradesh India.
      Journal
      3 Biotech
      3 Biotech
      Springer Nature
      2190-572X
      2190-5738
      Jan 2019
      : 9
      : 1
      30622874
      10.1007/s13205-018-1566-7
      1566
      6320706
      Keywords:

      Comments

      Comment on this article