40
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      A tool for the interactive analysis and exploration of in-vivo haemodynamics from 4D PC MRI

      research-article
      1 , , 1 , 1 , 2 , 2 , 4 , 3 , 1
      Journal of Cardiovascular Magnetic Resonance
      BioMed Central
      15th Annual SCMR Scientific Sessions
      2-5 February 2012

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background Time-resolved 3D (4D) phase contrast (PC) MRI allows deriving anatomical as well as functional information in the cardiovascular system. Progress in 4D MR techniques now facilitates volumetric, 3-directional, cine PC MRI data in reasonable scan times. The analysis of these data is, however, a challenging task because of the data complexity (3 spatial dimensions, 3 velocity directions, time) and the many processing steps required. Current evaluations of 4D PC MRI data often use a combination of home built and commercial tools, which are tailored to often time consuming (up to several hours) workflows for special research questions. The purpose of this study was to develop and evaluate a novel analysis tool that allows a fast interactive exploration of patient-specific 4D-PC hemodynamics. Methods The tool provides a combination of pre-processing and analysis methods including 4D phase offset error correction with 3rd order polynomials, antialiasing to correct of phase wraps, semi-automatic vessel segmentation, 3D flow visualization, and calculations of 4D pressure difference maps within the vessel volume. Based on this information, mean velocities and flow rates are calculated at user-defined cross sections of the vessel. Forward as well as backward tracking of pathlines emitted from user defined regions allows the visualization of flow pathways, which can be color-coded according to local velocity, direction, curvature or their emitter region (Fig 1). Figure 1 Visualization of flow pathways Results Experts with different clinical specialization analyzed a total of 11 cases (thoracic as well as cranial datasets). The evaluation consisted of the segmentation of the vessels of interest, animated visualizations of flow pathways, placement of several regions of interest, inspection and export of quantitative measurements of velocity and flow. The average processing times were 35.3min +/-14.4 min for the thoracic datasets and 45.2min+/-11.1 min for the cranial datasets. In addition, our clinical partners provided us with Doppler ultrasound measurements for 5 additional aortical cases with aortic coarctation, which we utilized for an assessment of the velocity estimation functionality in our tool. The 4D PCMRI datasets of these patients were analyzed using our tool, and measurements of peak velocity were performed at cross sections placed in the coarctation. We found a correlation coefficient of r=0.90 between the peak velocities measured by Doppler and the peak velocities computed by our tool from PC MRI data(Fig 2). Figure 2 Comparision of peak velocities measured by Doppler and by MRI Conclusions We presented a software tool that provides the improved functionality for the analysis and exploration of 4D PC MRI data including pre-processing, segmentation, quantification and visual exploration of flow patterns. We demonstrated the usability of our tool by clinical experts, and we presented a comparison with the clinically accepted Doppler ultrasound method. Funding Funded by the Deutsche Forschungsgemeinschaft project "Plaques der Aorta als Emboliequelle für Schlaganfälle" FR 2795/2-1.

          Related collections

          Author and article information

          Conference
          J Cardiovasc Magn Reson
          Journal of Cardiovascular Magnetic Resonance
          BioMed Central
          1097-6647
          1532-429X
          2012
          1 February 2012
          : 14
          : Suppl 1
          : W70
          Affiliations
          [1 ]Fraunhofer MEVIS, Bremen, Germany
          [2 ]Department of Radiology, Medical Physics, University Medical Center Freiburg, Freiburg, Germany
          [3 ]Departments of Radiology and Biomedical Engineering, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
          [4 ]Neurology, Universitätsklinik Freiburg, Freiburg, Germany
          Article
          1532-429X-14-S1-W70
          10.1186/1532-429X-14-S1-W70
          3305781
          f88ad12c-c93c-4728-b26d-24288619caea
          Copyright ©2012 Drexl et al; licensee BioMed Central Ltd.

          This is an open access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

          15th Annual SCMR Scientific Sessions
          Orlando, FL, USA
          2-5 February 2012
          History
          Categories
          Workshop Presentation

          Cardiovascular Medicine
          Cardiovascular Medicine

          Comments

          Comment on this article