          Abstract

          The aim of the study was to determine the possibilities of two differently acquired two-dimensional fast imaging with steady-state precession (FISP 2D) magnetic resonance sequences in estimation of the third ventricle floor fenestration patency after endoscopic third ventriculostomy (ETV) in the subjects with aqueductal stenosis/obstruction.Fifty eight subjects (37 males, 21 females, mean age 27 years) with previously successfully performed ETV underwent brain MRI on 1.5T MR imager 3-6 months after the procedure. Two different FISP 2D sequences (one included in the standard vendor provided software package, and the other, experimentally developed by our team) were performed respectively at two fixed slice positions: midsagittal and perpendicular to the ETV fenestration, and displayed in a closed-loop cinematographic format in order to estimate the patency. The ventricular volume reduction has been observed as well.Cerebrospinal fluid (CSF) flow through the ETV fenestration was observed in midsagittal plane with both FISP 2D sequences in 93.11% subjects, while in 6.89% subjects the dynamic CSF flow MRI was inconclusive. In the perpendicular plane CSF flow through the ETV fenestration was visible only by use of experimentally developed FISP 2D (TR30/FA70) sequence. Postoperative volume reduction of lateral and third ventricle was detected in 67.24% subjects.Though both FISP 2D sequences acquired in midsagittal plane may be used to estimate the effects of performed ETV, due to achieved higher CSF pulsatile flow sensitivity, only the use of FISP 2D (TR30/FA70) sequence enables the estimation of the treatment effect in perpendicular plane in the absence of phase-contrast sequences. 

          Related collections

          Author and article information

          Journal
          Bosn J Basic Med Sci
          Bosnian journal of basic medical sciences
          Association of Basic Medical Sciences of FBIH
          1840-4812
          1512-8601
          Aug 16 2014
          : 14
          : 3
          Affiliations
          [1 ] Oncology Institute of Vojvodina, Diagnostic Imaging Center, University of Novi Sad, University School of Medicine Novi Sad. milos.a.lucic@gmail.com.
          Article
          10.17305/bjbms.2014.3.37
          4333999
          25172977
          f956c367-ba27-4858-a79f-991feb3b49e2
          History

          Comments

          Comment on this article