      Influence of primer sequences and DNA extraction method on detection of non-O157 Shiga toxin-producing Escherichia coli in ground beef by real-time PCR targeting the eae, stx, and serogroup-specific genes.

      Journal of food protection
      Adhesins, Bacterial, genetics, Animals, Bacterial Typing Techniques, Cattle, Consumer Product Safety, DNA Primers, DNA, Bacterial, analysis, Escherichia coli Proteins, Food Contamination, Food Microbiology, Humans, Meat Products, microbiology, O Antigens, Real-Time Polymerase Chain Reaction, methods, Sensitivity and Specificity, Serotyping, Shiga Toxin, Shiga-Toxigenic Escherichia coli, classification, isolation & purification

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Non-O157 Shiga toxin-producing Escherichia coli (STEC) infections, particularly those caused by the "big six" or "top six" non-O157 serogroups (O26, O45, O103, O111, O121, and O145) can result in severe illness and complications. Because of their significant public health impact and the notable prevalence of STEC in cattle, methods for detection of the big six non-O157 STEC in ground beef have been established. Currently, the U.S. Department of Agriculture, Food Safety and Inspection Service detection methods for screening beef samples for non-O157 STEC target the stx(1), stx(2), and eae virulence genes, with the 16S rRNA gene as an internal control, in a real-time PCR multiplex assay. Further, the serogroup is determined by PCR targeting genes in the E. coli O-antigen gene clusters of the big six non-O157 serogroups. The method that we previously reported was improved so that additional stx variants, stx(1d), stx(2e), and stx(2g), are detected. Additionally, alignments of the primers targeting the eae gene were used to improve the detection assay so that eae subtypes that could potentially be of clinical significance would also be detected. Therefore, evaluation of alternative real-time PCR assay primers and probes for the stx and eae reactions was carried out in order to increase the stx and eae subtypes detected. Furthermore, a Tris-EDTA DNA extraction method was compared with a previously used procedure that was based on a commercially available reagent. The Tris-EDTA DNA extraction method significantly decreased the cycle threshold values for the stx assay (P < 0.0001) and eae assay (P < 0.0001), thereby increasing the ability to detect the targets. The use of different stx primers and probes increased the subtypes detected to include stx(1d), stx(2e), and stx(2g), and sequence data showed that modification of the eae primer should allow the known eae subtypes to be detected.

          Related collections

          Author and article information

          Comments

          Comment on this article