22
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Correction: Talin tension sensor reveals novel features of focal adhesion force transmission and mechanosensitivity

      correction

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Vol. 213 No. 3, May 9, 2016. Pages 371–383. In the original version of this article, the Discussion included the following text: While this manuscript was in revision, Austen et al. (2015) described an alternative talin-TS based on folded peptide hairpins that denature at forces in the 7–11-pN range. Although most of their results are consistent with ours, they found that a significant fraction of their 11-pN sensor was open in FAs, suggesting higher force. The hairpin, however, as expected for a folded domain, showed hysteresis when stretched in vitro; thus, it requires relatively high force to open but then can be maintained in the open state under lower tension. This sensor thus will report values that are biased toward the maximal forces, whereas the flagelliform spring is reversible and so should report mean tension. Analysis of forces on immobilized RGD peptides using folded domains or DNA hairpins also support the idea that peak forces can be high (Wang and Ha, 2013; Zhang et al., 2014; Galior et al., 2016), but these results cannot be interpreted as mean forces. After publication, the authors realized that the characterization of this related work was inaccurate. The new text reads: While this manuscript was in revision, Austen et al. (2015) described an alternative talin-TS based on folded peptide hairpins that denature at forces in the 7–11-pN range. Most of their results are consistent with ours; however, they found that a significant fraction of their 11-pN sensor was open in FAs, suggesting higher force. Any differences in reported tension across talin could be caused by some combination of differences in the way the in vitro calibrations are extrapolated to in vivo measurements or to differences in cell types and conditions. As a result of these changes, the references Wang and Ha, 2013; Zhang et al., 2014; and Galior et al., 2016 have been removed from the reference list. The authors apologize for any confusion this may have caused. The changes have been made in both the PDF and the online version. The error remains only in the print version.

          Related collections

          Author and article information

          Journal
          J Cell Biol
          J. Cell Biol
          jcb
          jcb
          The Journal of Cell Biology
          The Rockefeller University Press
          0021-9525
          1540-8140
          18 July 2016
          18 July 2016
          : 214
          : 2
          : 231
          Article
          20151001207062016c
          10.1083/jcb.20151001207062016c
          4949446
          27432899
          fbcb160e-7e0a-479c-ab24-4bcc780b5d0b
          © 2016 Kumar et al.
          History
          Categories
          Correction

          Cell biology
          Cell biology

          Comments

          Comment on this article