Effect of Central Line Bundle Compliance on Central Line-Associated Bloodstream Infections

Read this article at

Bookmark
      There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

      Abstract

      PurposeThe present study aimed to evaluate the effect of central line (CL) bundle compliance on central line-associated bloodstream infections (CLABSIs) in different departments of the same hospital, including the intensive care unit (ICU) and other departments.Materials and MethodsThe four components of the CL bundle were hand hygiene, use of maximal sterile barrier precautions, chlorhexidine use, and selection of an appropriate site for venous access. Compliance of the CL bundle and CLABSIs were measured for every department [emergency room (ER), ICU, general ward (GW), and operating room (OR)]. A total of 1672 patients were included over 3 years (August 2013 through July 2016).ResultsA total of 29 CLABSI episodes (1.73%) were identified, and only 53.7% of the patients completed CL bundles. The performance rates of all components of the CL bundle were 22.3%, 28.5%, 36.5%, and 84.6% for the ER, ICU, GW, and OR, respectively. The highest CLABSI rate was observed in patients of the ICU, for whom all components were not performed perfectly. Conversely, the lowest CLABSI rate was observed for patients of GWs, for whom all components were performed. Among individual components, femoral insertion site [relative risk (RR), 2.26; 95% confidence interval (CI), 1.09–4.68], not using a full body drape (RR, 3.55; 95% CI, 1.44–8.71), and not performing all CL bundle components (RR, 2.79; 95% CI, 1.19–6.54) were significant variables associated with CLABSIs.ConclusionThis study provides direct evidence that completing all CL bundle components perfectly is essential for preventing CLABSIs. Customized education should be provided, according to specific weaknesses of bundle performance.

      Related collections

      Most cited references 35

      • Record: found
      • Abstract: not found
      • Article: not found

      CDC/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting.

        Bookmark
        • Record: found
        • Abstract: found
        • Article: not found

        An intervention to decrease catheter-related bloodstream infections in the ICU.

        Catheter-related bloodstream infections occurring in the intensive care unit (ICU) are common, costly, and potentially lethal. We conducted a collaborative cohort study predominantly in ICUs in Michigan. An evidence-based intervention was used to reduce the incidence of catheter-related bloodstream infections. Multilevel Poisson regression modeling was used to compare infection rates before, during, and up to 18 months after implementation of the study intervention. Rates of infection per 1000 catheter-days were measured at 3-month intervals, according to the guidelines of the National Nosocomial Infections Surveillance System. A total of 108 ICUs agreed to participate in the study, and 103 reported data. The analysis included 1981 ICU-months of data and 375,757 catheter-days. The median rate of catheter-related bloodstream infection per 1000 catheter-days decreased from 2.7 infections at baseline to 0 at 3 months after implementation of the study intervention (P< or =0.002), and the mean rate per 1000 catheter-days decreased from 7.7 at baseline to 1.4 at 16 to 18 months of follow-up (P<0.002). The regression model showed a significant decrease in infection rates from baseline, with incidence-rate ratios continuously decreasing from 0.62 (95% confidence interval [CI], 0.47 to 0.81) at 0 to 3 months after implementation of the intervention to 0.34 (95% CI, 0.23 to 0.50) at 16 to 18 months. An evidence-based intervention resulted in a large and sustained reduction (up to 66%) in rates of catheter-related bloodstream infection that was maintained throughout the 18-month study period. Copyright 2006 Massachusetts Medical Society.
          Bookmark
          • Record: found
          • Abstract: not found
          • Article: not found

          Preventing complications of central venous catheterization.

            Bookmark

            Author and article information

            Affiliations
            [1 ]Division of Infectious Diseases, Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
            [2 ]Department of Infection Control, Gangnam Severance Hospital, Seoul, Korea.
            Author notes
            Corresponding author: Dr. Young Goo Song, Division of Infectious Diseases, Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, 211 Eonju-ro, Gangnam-gu, Seoul 06273, Korea. Tel: 82-2-2019-3319, Fax: 82-2-3463-3882, imfell@ 123456yuhs.ac
            Journal
            Yonsei Med J
            Yonsei Med. J
            YMJ
            Yonsei Medical Journal
            Yonsei University College of Medicine
            0513-5796
            1976-2437
            01 May 2018
            30 March 2018
            : 59
            : 3
            : 376-382
            29611399
            5889989
            10.3349/ymj.2018.59.3.376
            © Copyright: Yonsei University College of Medicine 2018

            This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ( http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

            Categories
            Original Article
            Infectious Diseases

            Medicine

            central venous catheter, catheter-associated infection, central line bundle

            Comments

            Comment on this article