28
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Reassessment of the risk of healthcare-acquired infection during rigid laryngoscopy.

      1
      The Journal of hospital infection
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Inadequate reprocessing of rigid laryngoscopes has been linked to nosocomial outbreaks with associated morbidity and mortality. Last year an outbreak of Pseudomonas aeruginosa in a neonatal intensive care unit was responsible for multiple infections and colonisations, and at least two infant deaths. An investigation of this outbreak identified contaminated rigid laryngoscopes as its source, demonstrating that inadequate reprocessing of rigid laryngoscopes remains a current public health concern. This article revisits and reassesses the risk of healthcare-acquired infection during rigid laryngoscopy and establishes the minimum reprocessing requirements for blades and handles of rigid laryngoscopes. Several potential risk factors for microbial transmission are identified and discussed, including the publication of inconsistent reprocessing guidelines for rigid laryngoscopes. Concern about guidelines that recommend low-level or intermediate-level disinfection of rigid laryngoscopes is expressed. The use of a sterile disposable sheath to cover the rigid laryngoscope and minimise the risk of contamination is also discussed. Regardless of whether a sheath is used during the procedure, thorough cleaning followed by high-level disinfection and drying of the instrument is recommended to prevent microbial transmission.

          Related collections

          Author and article information

          Journal
          J. Hosp. Infect.
          The Journal of hospital infection
          Elsevier BV
          0195-6701
          0195-6701
          Feb 2008
          : 68
          : 2
          Affiliations
          [1 ] Custom Ultrasonics, Inc., Research and Development, 144 Railroad Drive, Ivyland, PA 18974, USA. LFM@myendosite.com
          Article
          S0195-6701(07)00410-0
          10.1016/j.jhin.2007.11.004
          18226421
          fcc8ebf8-8411-40f4-aac1-4ae410de6716
          History

          Comments

          Comment on this article