      Intraoperative Fluoroscopy Improves Component Position During Anterior Hip Arthroplasty.

      , , , ,
      Orthopedics
      SLACK, Inc.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The goal of this retrospective review was to determine whether fluoroscopic guidance improves acetabular cup abduction and anteversion alignment during anterior total hip arthroplasty. The authors retrospectively reviewed 199 patients (fluoroscopy group, 98; nonfluoroscopy group, 101) who underwent anterior total hip arthroplasty at a single center with and without C-arm fluoroscopy guidance. Included in the study were patients of any age who underwent primary anterior approach total hip arthroplasty performed by a single surgeon, with 6-month postoperative anteroposterior pelvis radiographs. Acetabular cup abduction and anteversion angles were measured and compared between groups. Mean acetabular cup abduction and anteversion angles were 43.4° (range, 26.0°-57.4°) and 23.1° (range, 17°-28°), respectively, in the fluoroscopy group. Mean abduction and anteversion angles were 45.9° (range, 29.7°-61.3°) and 23.1° (range, 17°-28°), respectively, after anterior total hip arthroplasty without the use of C-arm guidance (nonfluoroscopy group). The use of fluoroscopy was associated with a statistically significant difference in cup abduction (P=.002) but no statistically significant difference in anteversion angles. In the fluoroscopy group, 80% of implants were within the combined safe zone compared with 63% in the nonfluoroscopy group. A significantly higher percentage of both acetabular cup abduction angles and combined anteversion and abduction angles were in the safe zone in the fluoroscopy group. Fluoroscopy is not required for proper anteversion placement of acetabular components, but it may increase ideal safe zone placement of components.

          Related collections

          Author and article information

          Journal
          Orthopedics
          Orthopedics
          SLACK, Inc.
          1938-2367
          0147-7447
          Nov 2015
          : 38
          : 11
          Article
          10.3928/01477447-20151020-04
          26558676
          fd5ae1cb-6b6f-42eb-ba7a-018a6ea5d8d6
          History

          Comments

          Comment on this article