      Do changes in pulse pressure variation and inferior vena cava distensibility during passive leg raising and tidal volume challenge detect preload responsiveness in case of low tidal volume ventilation?

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          In patients ventilated with tidal volume ( Vt) < 8 mL/kg, pulse pressure variation (PPV) and, likely, the variation of distensibility of the inferior vena cava diameter (IVCDV) are unable to detect preload responsiveness. In this condition, passive leg raising (PLR) could be used, but it requires a measurement of cardiac output. The tidal volume (Vt) challenge (PPV changes induced by a 1-min increase in Vt from 6 to 8 mL/kg) is another alternative, but it requires an arterial line. We tested whether, in case of Vt = 6 mL/kg, the effects of PLR could be assessed through changes in PPV (ΔPPV PLR) or in IVCDV (ΔIVCDV PLR) rather than changes in cardiac output, and whether the effects of the Vt challenge could be assessed by changes in IVCDV (ΔIVCDV Vt) rather than changes in PPV (ΔPPV Vt).

          Methods

          In 30 critically ill patients without spontaneous breathing and cardiac arrhythmias, ventilated with Vt = 6 mL/kg, we measured cardiac index (CI) (PiCCO2), IVCDV and PPV before/during a PLR test and before/during a Vt challenge. A PLR-induced increase in CI ≥ 10% defined preload responsiveness.

          Results

          At baseline, IVCDV was not different between preload responders ( n = 15) and non-responders. Compared to non-responders, PPV and IVCDV decreased more during PLR (by − 38 ± 16% and − 26 ± 28%, respectively) and increased more during the Vt challenge (by 64 ± 42% and 91 ± 72%, respectively) in responders. ∆PPV PLR, expressed either as absolute or as percent relative changes, detected preload responsiveness (area under the receiver operating curve, AUROC: 0.98 ± 0.02 for both). ∆IVCDV PLR detected preload responsiveness only when expressed in absolute changes (AUROC: 0.76 ± 0.10), not in relative changes. ∆PPV Vt, expressed as absolute or percent relative changes, detected preload responsiveness (AUROC: 0.98 ± 0.02 and 0.94 ± 0.04, respectively). This was also the case for ∆IVCDV Vt, but the diagnostic threshold (1 point or 4%) was below the least significant change of IVCDV (9[3–18]%).

          Conclusions

          During mechanical ventilation with Vt = 6 mL/kg, the effects of PLR can be assessed by changes in PPV. If IVCDV is used, it should be expressed in percent and not absolute changes. The effects of the Vt challenge can be assessed on PPV, but not on IVCDV, since the diagnostic threshold is too small compared to the reproducibility of this variable.

          Trial registration: Agence Nationale de Sécurité du Médicament et des Produits de santé: ID-RCB: 2016-A00893-48.

          Supplementary Information

          The online version contains supplementary material available at 10.1186/s13054-021-03515-7.

          Related collections

          Most cited references27

          • Record: found
          • Abstract: found
          • Article: not found

          The respiratory variation in inferior vena cava diameter as a guide to fluid therapy.

          To investigate whether the respiratory variation in inferior vena cava diameter (DeltaD(IVC)) could be related to fluid responsiveness in mechanically ventilated patients. Prospective clinical study. Medical ICU of a non-university hospital. Mechanically ventilated patients with septic shock (n=39). Volume loading with 8 mL/kg of 6% hydroxyethylstarch over 20 min. Cardiac output and DeltaD(IVC) were assessed by echography before and immediately after the standardized volume load. Volume loading induced an increase in cardiac output from 5.7+/-2.0 to 6.4+/-1.9 L/min (P or =15% (responders). Before volume loading, the DeltaD(IVC) was greater in responders than in non-responders (25+/-15 vs 6+/-4%, P<0.001), closely correlated with the increase in cardiac output (r=0.82, P<0.001), and a 12% DeltaD(IVC) cut-off value allowed identification of responders with positive and negative predictive values of 93% and 92%, respectively. Analysis of DeltaD(IVC) is a simple and non-invasive method to detect fluid responsiveness in mechanically ventilated patients with septic shock.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients.

            To evaluate the extent to which respiratory changes in inferior vena cava (IVC) diameter can be used to predict fluid responsiveness. Prospective clinical study. Hospital intensive care unit. Twenty-three patients with acute circulatory failure related to sepsis and mechanically ventilated because of an acute lung injury. Inferior vena cava diameter (D) at end-expiration (Dmin) and at end-inspiration (Dmax) was measured by echocardiography using a subcostal approach. The distensibility index of the IVC (dIVC) was calculated as the ratio of Dmax - Dmin / Dmin, and expressed as a percentage. The Doppler technique was applied in the pulmonary artery trunk to determine cardiac index (CI). Measurements were performed at baseline and after a 7 ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in CI > or =15%) and non-responders (increase in CI <15%). Using a threshold dIVC of 18%, responders and non-responders were discriminated with 90% sensitivity and 90% specificity. A strong relation (r = 0.9) was observed between dIVC at baseline and the CI increase following blood volume expansion. Baseline central venous pressure did not accurately predict fluid responsiveness. Our study suggests that respiratory change in IVC diameter is an accurate predictor of fluid responsiveness in septic patients.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Prediction of fluid responsiveness: an update

              In patients with acute circulatory failure, the decision to give fluids or not should not be taken lightly. The risk of overzealous fluid administration has been clearly established. Moreover, volume expansion does not always increase cardiac output as one expects. Thus, after the very initial phase and/or if fluid losses are not obvious, predicting fluid responsiveness should be the first step of fluid strategy. For this purpose, the central venous pressure as well as other “static” markers of preload has been used for decades, but they are not reliable. Robust evidence suggests that this traditional use should be abandoned. Over the last 15 years, a number of dynamic tests have been developed. These tests are based on the principle of inducing short-term changes in cardiac preload, using heart–lung interactions, the passive leg raise or by the infusion of small volumes of fluid, and to observe the resulting effect on cardiac output. Pulse pressure and stroke volume variations were first developed, but they are reliable only under strict conditions. The variations in vena caval diameters share many limitations of pulse pressure variations. The passive leg-raising test is now supported by solid evidence and is more frequently used. More recently, the end-expiratory occlusion test has been described, which is easily performed in ventilated patients. Unlike the traditional fluid challenge, these dynamic tests do not lead to fluid overload. The dynamic tests are complementary, and clinicians should choose between them based on the status of the patient and the cardiac output monitoring technique. Several methods and tests are currently available to identify preload responsiveness. All have some limitations, but they are frequently complementary. Along with elements indicating the risk of fluid administration, they should help clinicians to take the decision to administer fluids or not in a reasoned way.
                Bookmark

                Author and article information

                Contributors
                taccheri.temistocle@gmail.com
                gavelli.francesco@gmail.com
                jean-louis.teboul@aphp.fr
                shiruidingding@hotmail.com
                xavier.monnet@aphp.fr
                Journal
                Crit Care
                Critical Care
                BioMed Central (London )
                1364-8535
                1466-609X
                18 March 2021
                18 March 2021
                2021
                : 25
                : 110
                Affiliations
                GRID grid.460789.4, ISNI 0000 0004 4910 6535, AP-HP, Service de médecine intensive-réanimation, Hôpital de Bicêtre, DMU CORREVE, Inserm UMR S_999, FHU SEPSIS, Groupe de Recherche Clinique CARMAS, , Université Paris-Saclay, ; 78, Rue du Général Leclerc, 94 270 Le Kremlin-Bicêtre, France
                Author information
                http://orcid.org/0000-0002-8236-9762
                Article
                3515
                10.1186/s13054-021-03515-7
                7972024
                33736672
                fe7d2db2-4944-4bd3-a96a-0d0f5e4e4970
                © The Author(s) 2021

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

                History
                : 23 November 2020
                : 18 February 2021
                Categories
                Research
                Custom metadata
                © The Author(s) 2021

                Emergency medicine & Trauma
                fluid responsiveness,stroke volume variation,acute respiratory distress syndrome,fluid challenge

                Comments

                Comment on this article