30
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Hydrolytic degradation characteristics of aliphatic polyesters derived from lactic and glycolic acids

       
      Journal of Biomedical Materials Research
      Wiley-Blackwell

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references47

          • Record: found
          • Abstract: not found
          • Article: not found

          Investigation of the structure of solution grown crystals of lactide copolymers by means of chemical reactions

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Degradation rates of oral resorbable implants (polylactates and polyglycolates): rate modification with changes in PLA/PGA copolymer ratios.

              This study determined the difference in rate of degradation between pure polymers of lactic acid (pla), glycolic acid (PGA), and various ratios of copolymers of these two substances. Fast-cured and slow-cured polyglycolide was compared with copolymers of glycolide/lactide intermixed in ratios of 75:25, 50:50, and 25:75, as well as pure polylactide. A total of 420 rats were implanted with carbon-14 and tritium-labeled polymers in bone and soft tissue. At intervals of 1, 2, 3, 5, 7, 9, and 11 months, groups of five animals with the implants in bone and five with the implants in the abdominal wall were sacrificed. The implant area as well as tissue from the liver, spleen, kidney, lung and some muscle tissue was analyzed for radioactivity along with the urine and feces collected throughout the experiment. Half-lives of the different polymers and copolymers were calculated from the radioactivity present in the implant area for each time interval. Half-life of the polymers and copolymers decreased from 5 months for 100% PGA to 1 week with 50:50 PGA:PLA copolymer and rapidly increased to 6.1 months for 100% PLA. Fast-cured PGA had a half-life in tissue of 0.85 months. No difference in rate of degradation was seen in soft tissue or bone. No significant radioactivity was detected in urine, feces, or tissue samples. From this study, it is concluded that control of degradation rate of the implant could best be attained by varying the composition of PLA and PGA between 75% and 100% PLA along with a corresponding 25% to 0% PGA. This would provide a half-life range of the implant of from 2 weeks to 6 months.
                Bookmark

                Author and article information

                Journal
                Journal of Biomedical Materials Research
                J. Biomed. Mater. Res.
                Wiley-Blackwell
                0021-9304
                1097-4636
                1999
                1999
                : 48
                : 3
                : 342-353
                Article
                10.1002/(SICI)1097-4636(1999)48:3<342::AID-JBM20>3.0.CO;2-7
                febca282-85c0-47b9-a524-7ea9e0181ec2
                © 1999

                http://doi.wiley.com/10.1002/tdm_license_1.1

                History

                Comments

                Comment on this article