47
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Cough aerosol in healthy participants: fundamental knowledge to optimize droplet-spread infectious respiratory disease management

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          The Influenza A H1N1 virus can be transmitted via direct, indirect, and airborne route to non-infected subjects when an infected patient coughs, which expels a number of different sized droplets to the surrounding environment as an aerosol. The objective of the current study was to characterize the human cough aerosol pattern with the aim of developing a standard human cough bioaerosol model for Influenza Pandemic control.

          Method

          45 healthy non-smokers participated in the open bench study by giving their best effort cough. A laser diffraction system was used to obtain accurate, time-dependent, quantitative measurements of the size and number of droplets expelled by the cough aerosol.

          Results

          Voluntary coughs generated droplets ranging from 0.1 - 900 microns in size. Droplets of less than one-micron size represent 97% of the total number of measured droplets contained in the cough aerosol. Age, sex, weight, height and corporal mass have no statistically significant effect on the aerosol composition in terms of size and number of droplets.

          Conclusions

          We have developed a standard human cough aerosol model. We have quantitatively characterized the pattern, size, and number of droplets present in the most important mode of person-to-person transmission of IRD: the cough bioaerosol. Small size droplets (< 1 μm) predominated the total number of droplets expelled when coughing. The cough aerosol is the single source of direct, indirect and/or airborne transmission of respiratory infections like the Influenza A H1N1 virus.

          Study design

          Open bench, Observational, Cough, Aerosol study

          Related collections

          Most cited references44

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Review of Aerosol Transmission of Influenza A Virus

          Concerns about the likely occurrence of an influenza pandemic in the near future are increasing. The highly pathogenic strains of influenza A (H5N1) virus circulating in Asia, Europe, and Africa have become the most feared candidates for giving rise to a pandemic strain. Several authors have stated that large-droplet transmission is the predominant mode by which influenza virus infection is acquired ( 1 – 3 ). As a consequence of this opinion, protection against infectious aerosols is often ignored for influenza, including in the context of influenza pandemic preparedness. For example, the Canadian Pandemic Influenza Plan and the US Department of Health and Human Services Pandemic Influenza Plan ( 4 , 5 ) recommend surgical masks, not N95 respirators, as part of personal protective equipment (PPE) for routine patient care. This position contradicts the knowledge on influenza virus transmission accumulated in the past several decades. Indeed, the relevant chapters of many reference books, written by recognized authorities, refer to aerosols as an important mode of transmission for influenza ( 6 – 9 ). In preparation for a possible pandemic caused by a highly lethal virus such as influenza A (H5N1), making the assumption that the role of aerosols in transmission of this virus will be similar to their role in the transmission of known human influenza viruses would seem rational. Because infection with influenza A (H5N1) virus is associated with high death rates and because healthcare workers cannot as yet be protected by vaccination, recommending an enhanced level of protection, including the use of N95 respirators as part of PPE, is important. Following are a brief review of the relevant published findings that support the importance of aerosol transmission of influenza and a brief discussion on the implications of these findings on pandemic preparedness. Influenza Virus Aerosols By definition, aerosols are suspensions in air (or in a gas) of solid or liquid particles, small enough that they remain airborne for prolonged periods because of their low settling velocity. For spherical particles of unit density, settling times (for a 3-m fall) for specific diameters are 10 s for 100 μm, 4 min for 20 μm, 17 min for 10 μm, and 62 min for 5 μm; particles with a diameter 6-μm diameter are trapped increasingly in the upper respiratory tract ( 12 ); no substantial deposition in the lower respiratory tract occurs at >20 μm ( 11 , 12 ). Many authors adopt a size cutoff of 10–20 μm will settle rapidly, will not be deposited in the lower respiratory tract, and are referred to as large droplets ( 10 – 12 ). Coughing or sneezing generates a substantial quantity of particles, a large number of which are 40%. The increased survival of influenza virus in aerosols at low relative humidity has been suggested as a factor that accounts for the seasonality of influenza ( 15 , 16 ). The sharply increased decay of infectivity at high humidity has also been observed for other enveloped viruses (e.g., measles virus); in contrast, exactly the opposite relationship has been shown for some nonenveloped viruses (e.g., poliovirus) ( 11 , 15 , 16 ). Experimental Influenza Infection Experimental infection studies permit the clear separation of the aerosol route of transmission from transmission by large droplets. Laboratory preparation of homogeneous small particle aerosols free of large droplets is readily achieved ( 13 , 18 ). Conversely, transmission by large droplets without accompanying aerosols can be achieved by intranasal drop inoculation ( 13 ). Influenza infection has been documented by aerosol exposure in the mouse model, the squirrel monkey model, and human volunteers ( 12 , 13 , 17 – 19 ). Observations made during experimental infections with human volunteers are particularly interesting and relevant. In studies conducted by Alford and colleagues ( 18 ), volunteers were exposed to carefully titrated aerosolized influenza virus suspensions by inhaling 10 L of aerosol through a face mask. The diameter of the aerosol particles was 1 μm–3 μm. Demonstration of infection in participants in the study was achieved by recovery of infectious viruses from throat swabs, taken daily, or by seroconversion, i.e., development of neutralizing antibodies. The use of carefully titrated viral stocks enabled the determination of the minimal infectious dose by aerosol inoculation. For volunteers who lacked detectable neutralizing antibodies at the onset, the 50% human infectious dose (HID50) was 0.6–3.0 TCID50, if one assumes a retention of 60% of the inhaled particles (18). In contrast, the HID50 measured when inoculation was performed by intranasal drops was 127–320 TCID50 ( 13 ). Additional data from experiments conducted with aerosolized influenza virus (average diameter 1.5 μm) showed that when a dose of 3 TCID50 was inhaled, ≈1 TCID50 only was deposited in the nose ( 12 ). Since the dose deposited in the nose is largely below the minimal dose required by intranasal inoculation, this would indicate that the preferred site of infection initiation during aerosol inoculation is the lower respiratory tract. Another relevant observation is that whereas the clinical symptoms initiated by aerosol inoculation covered the spectrum of symptoms seen in natural infections, the disease observed in study participants infected experimentally by intranasal drops was milder, with a longer incubation time and usually no involvement of the lower respiratory tract ( 13 , 20 ). For safety reasons, this finding led to the adoption of intranasal drop inoculation as the standard procedure in human experimental infections with influenza virus ( 13 ). Additional support for the view that the lower respiratory tract (which is most efficiently reached by the aerosol route) is the preferred site of infection is provided by studies on the use of zanamivir for prophylaxis. In experimental settings, intranasal zanamivir was protective against experimental inoculation with influenza virus in intranasal drops ( 21 ). However, in studies on prophylaxis of natural infection, intranasally applied zanamivir was not protective ( 22 ), whereas inhaled zanamivir was protective in one study ( 23 ) and a protective effect approached statistical significance in another study ( 22 ). These experiments and observations strongly support the view that many, possibly most, natural influenza infections occur by the aerosol route and that the lower respiratory tract may be the preferred site of initiation of the infection. Epidemiologic Observations In natural infections, the postulated modes of transmission have included aerosols, large droplets, and direct contact with secretions or fomites because the virus can remain infectious on nonporous dry surfaces for >(January 2006) recommends FFP2 respirators (equivalent to N95 respirators) (http://www.splf.org/s/IMG/pdf/plan-grip-janvier06.pdf). Given the scientific evidence that supports the occurrence of aerosol transmission of influenza, carefully reexamining current recommendations for PPE equipment would appear necessary.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Characterization of expiration air jets and droplet size distributions immediately at the mouth opening

            Size distributions of expiratory droplets expelled during coughing and speaking and the velocities of the expiration air jets of healthy volunteers were measured. Droplet size was measured using the interferometric Mie imaging (IMI) technique while the particle image velocimetry (PIV) technique was used for measuring air velocity. These techniques allowed measurements in close proximity to the mouth and avoided air sampling losses. The average expiration air velocity was 11.7 m/s for coughing and 3.9 m/s for speaking. Under the experimental setting, evaporation and condensation effects had negligible impact on the measured droplet size. The geometric mean diameter of droplets from coughing was 13.5 μm and it was 16.0 μm for speaking (counting 1–100). The estimated total number of droplets expelled ranged from 947 to 2085 per cough and 112–6720 for speaking. The estimated droplet concentrations for coughing ranged from 2.4 to 5.2 cm−3 per cough and 0.004–0.223 cm−3 for speaking.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Flow dynamics and characterization of a cough.

              Airborne disease transmission has always been a topic of wide interests in various fields for decades. Cough is found to be one of the prime sources of airborne diseases as it has high velocity and large quantity of droplets. To understand and characterize the flow dynamics of a cough can help to control the airborne disease transmission. This study has measured flow dynamics of coughs with human subjects. The flow rate variation of a cough with time can be represented as a combination of gamma-probability-distribution functions. The variables needed to define the gamma-probability-distribution functions can be represented by some medical parameters. A robust multiple linear regression analysis indicated that these medical parameters can be obtained from the physiological details of a person. However, the jet direction and mouth opening area during a cough seemed not related to the physiological parameters of the human subjects. Combining the flow characteristics reported in this study with appropriate virus and droplet distribution information, the infectious source strength by coughing can be evaluated. There is a clear need for the scientific community to accurately predict and control the transmission of airborne diseases. Transportation of airborne viruses is often predicted using Computational Fluid Dynamics (CFD) simulations. CFD simulations are inexpensive but need accurate source boundary conditions for the precise prediction of disease transmission. Cough is found to be the prime source for generating infectious viruses. The present study was designed to develop an accurate source model to define thermo-fluid boundary conditions for a cough. The model can aid in accurately predicting the disease transmission in various indoor environments, such as aircraft cabins, office spaces and hospitals.
                Bookmark

                Author and article information

                Journal
                BMC Pulm Med
                BMC Pulm Med
                BMC Pulmonary Medicine
                BioMed Central
                1471-2466
                2012
                21 March 2012
                : 12
                : 11
                Affiliations
                [1 ]Mucophysiology Laboratory, Department of Medicine, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
                [2 ]Department of Medicine, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
                [3 ]Centre for Lung Health, Northern Lung Function Laboratory, Edmonton General Hospital, Edmonton, AB, Canada
                [4 ]Department of Mechanical Engineering, Faculty of Engineering, University of Alberta, Edmonton, AB, Canada
                [5 ]Department of Public Health Sciences, School of Public Health, University of Alberta, Edmonton, AB, Canada
                Article
                1471-2466-12-11
                10.1186/1471-2466-12-11
                3331822
                22436202
                ff2e659d-12ea-4aac-8495-c391d64dbb28
                Copyright ©2012 Zayas et al; licensee BioMed Central Ltd.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 8 September 2011
                : 21 March 2012
                Categories
                Research Article

                Respiratory medicine
                Respiratory medicine

                Comments

                Comment on this article