23
views
0
recommends
+1 Recommend
1 collections
    0
    shares

      Call for Papers: Green Renal Replacement Therapy: Caring for the Environment

      Submit here before September 30, 2024

      About Blood Purification: 3.0 Impact Factor I 5.6 CiteScore I 0.83 Scimago Journal & Country Rank (SJR)

      • Record: found
      • Abstract: found
      • Article: found

      Ultrapure Dialysate Reduces Plasma Levels of β 2-Microglobulin and Pentosidine in Hemodialysis Patients

      research-article

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background: β<sub>2</sub>-Microglobulin (β<sub>2</sub>MG) and carbonyl stress are reported to contribute to the development of dialysis-related amyloidosis. The aim of this study was to determine whether the purity of dialysate affects plasma levels of β<sub>2</sub>MG and pentosidine (a surrogate marker of carbonyl stress) in hemodialysis patients. Methods: Sixteen patients on hemodialysis with a polysulfone membrane participated in this study. We switched the dialysate from conventional dialysate (endotoxin level 0.055–0.066 endotoxin units (EU)/ml) to ultrapure dialysate (endotoxin level <0.001 EU/ml), followed patients for 6 months, and then switched back to conventional dialysate once again. Plasma levels of β<sub>2</sub>MG, pentosidine, CRP and interleukin-6 (IL-6) were determined before the switch to ultrapure dialysate, 1 and 6 months after the switch to ultrapure dialysate, and 1 month after the switch back to conventional dialysate. Results: The switch from conventional to ultrapure dialysate significantly decreased plasma levels of β<sub>2</sub>MG, from 30.1 ± 1.4 to 27.1 ± 1.4 mg/dl (p < 0.05) and pentosidine, from 1,535.8 ± 107.5 to 1,267.6 ± 102.9 nmol/l (p < 0.01) after 1 month of use. The change of dialysate also significantly decreased plasma levels of CRP, from 0.28 ± 0.09 to 0.14 ± 0.05 mg/dl (p < 0.05) and IL-6, from 9.4 ± 2.7 to 3.5 ± 0.8 pg/ml (p < 0.01) over the 1-month period. These changes in plasma levels of β<sub>2</sub>MG, pentosidine, CRP and IL-6 were maintained over 6 months after switching to ultrapure dialysate and returned to basal levels by switching back to a conventional dialysate. Conclusions: Ultrapure dialysate decreases plasma levels of β<sub>2</sub>MG, pentosidine and inflammatory markers in hemodialysis patients. The use of ultrapure dialysate might be useful in preventing and/or treating complications of dialysis, such as dialysis-related amyloidosis, atherosclerosis and malnutrition.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: not found
          • Article: not found

          A new form of amyloid protein associated with chronic hemodialysis was identified as β2-microglobulin

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Dialysate related cytokine induction and response to recombinant human erythropoietin in haemodialysis patients.

            Chronic inflammatory disorders or infections represent a major cause of hyporesponsiveness to recombinant human erythropoietin (rHuEpo). To test the hypothesis that dialysate-related cytokine induction alters the response to rHuEpo, we conducted a prospective study with matched pairs of chronic haemodialysis patients. We compared the effect of two dialysis fluids, differing in their microbiological quality, on the rHuEpo therapy. Thirty male patients with end-stage renal disease maintained on regular haemodialysis were assigned either to a group treated with conventional (potentially microbiologically contaminated) dialysate (group I) or to a group treated with online-produced ultrapure dialysate (group II). Randomization was stratified according to the maintenance dose of rHuEpo necessary to maintain a target haemoglobin level of 10-10.5 g/dl. Patients were followed for 12 months. Kt/V was calculated by the formula of Daugirdas. Haemoglobin levels were measured weekly and serum ferritin concentrations were determined at 6-week intervals. C-reactive protein (CRP) and interleukin-6 (IL-6) was measured by an ELISA at the start of the study and after 3, 6 and 12 months. In group I, continuous use of bicarbonate dialysate did not change the rHuEpo dosage given to achieve the target haemoglobin level and was associated with elevated surrogate markers (CRP, IL-6) of cytokine-induced inflammation. The switch from conventional to online-produced ultrapure dialysate in group II resulted in a lower bacterial contamination with a significant decrease of CRP and IL-6 blood levels. It was accompanied by a significant and sustained reduction of the rHuEpo dosage, which was required to correct the anaemia. Using multiple regression analysis, IL-6 levels are shown to have a strong predictive value for rHuEpo dosage in both groups. Our data demonstrate that dialysate-related factors such as low bacterial contamination can induce the activation of monocytes, resulting in elevated serum levels of IL-6. Dialysate-related cytokine induction might diminish erythropoiesis. The use of pyrogen free ultrapure dialysate resulted in a better response to rHuEpo. Not only would it save money, but it would also help to maintain an optimal haemoglobin level without further increase in rHuEpo dosage.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Switch from conventional to high-flux membrane reduces the risk of carpal tunnel syndrome and mortality of hemodialysis patients.

              The use of a high-flux membrane, which eliminates larger molecular weight solutes with better biocompatibility, has steadily increased since the discovery of beta-2 microglobulin (beta 2m) amyloidosis in 1985. The long-term effects of a dialyzer membrane on morbidity and mortality are not completely understood. To examine the membrane effect as a factor of carpal tunnel syndrome onset and mortality, multivariate Cox regression analysis with time-dependent covariate was conducted on 819 patients from March 1968 to November 1994 at a single center. Two hundred and forty-eight of the patients were either switched from the conventional to high-flux membrane or treated only with a high-flux membrane. Fifty-one patients underwent a CTS operation and 206 died. Membrane status (on high-flux or on conventional) was considered as time-dependent covariate and risk was adjusted for age, gender, type of renal disease and calendar year of dialysis initiation. The relative risk of CTS was reduced to 0.503 (P < 0.05) and mortality 0.613 (P < 0.05) by dialysis on the high-flux membrane, compared to the conventional membrane. Serial measurements of beta 2m indicated significantly lower beta 2m to persist in patients on the high-flux membrane. The high-flux membrane decreased the risk of morbidity and mortality substantially. Larger molecule elimination was shown important not only for preventing beta 2m amyloidosis, but for prolonging survival of dialysis patients as well.
                Bookmark

                Author and article information

                Journal
                BPU
                Blood Purif
                10.1159/issn.0253-5068
                Blood Purification
                S. Karger AG
                0253-5068
                1421-9735
                2005
                September 2005
                04 October 2005
                : 23
                : 4
                : 311-316
                Affiliations
                aRenal Division, Department of Internal Medicine, Iwata City Hospital, Iwata; bDepartment of Clinical Nutrition, School of Food and Nutritional Sciences, University of Shizuoka, Shizuoka, and cDepartment of Orthopedic Surgery and dFirst Department of Medicine, Hamamatsu University School of Medicine, Hamamatsu, Japan
                Article
                86554 Blood Purif 2005;23:311–316
                10.1159/000086554
                15980621
                eb063bd0-a155-4b8e-800f-e69cd8b96221
                © 2005 S. Karger AG, Basel

                Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

                History
                : 05 January 2005
                : 14 April 2005
                Page count
                Figures: 1, Tables: 2, References: 33, Pages: 6
                Categories
                Original Paper

                Cardiovascular Medicine,Nephrology
                β2-Microglobulin,Chronic inflammation,Dialysate purity,Pentosidine

                Comments

                Comment on this article