          Abstract

          Super-resolution fluorescence imaging techniques allow optical imaging of specimens beyond the diffraction limit of light. Super-resolution optical fluctuation imaging (SOFI) relies on computational analysis of stochastic blinking events to obtain a super-resolved image. As with some other super-resolution methods, this strong dependency on computational analysis can make it difficult to gauge how well the resulting images reflect the underlying sample structure. We herein report SOFIevaluator, an unbiased and parameter-free algorithm for calculating a set of metrics that describes the quality of super-resolution fluorescence imaging data for SOFI. We additionally demonstrate how SOFIevaluator can be used to identify fluorescent proteins that perform well for SOFI imaging under different imaging conditions.

          Related collections

          Author and article information

          Journal
          Biomed Opt Express
          Biomed Opt Express
          BOE
          Biomedical Optics Express
          Optical Society of America
          2156-7085
          07 January 2020
          01 February 2020
          : 11
          : 2
          : 636-648
          Affiliations
          [1 ]Laboratory for NanoBiology, Department of Chemistry, KU Leuven, Celestijnenlaan 200G, 3001 Heverlee, Belgium
          [2 ] benjamien.moeyaert@ 123456kuleuven.be
          [3 ] peter.dedecker@ 123456kuleuven.be
          Author information
          https://orcid.org/0000-0003-1643-9993
          https://orcid.org/0000-0002-5888-9100
          https://orcid.org/0000-0002-1882-2075
          Article
          PMC7041449 PMC7041449 7041449 382278
          10.1364/BOE.382278
          7041449
          32133218
          96f61451-320d-4e3a-b4b7-f393fb40b088
          © 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

          © 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

          History
          : 12 November 2019
          : 18 December 2019
          : 19 December 2019
          Funding
          Funded by: Fonds Wetenschappelijk Onderzoek 10.13039/501100003130
          Award ID: 12H8316N
          Award ID: G090819N
          Award ID: G0B8817N
          Funded by: European Research Council 10.13039/501100000781
          Award ID: 714688
          Categories
          Article

          Comments

          Comment on this article