      Native T1 mapping: inter-study, inter-observer and inter-center reproducibility in hemodialysis patients

      Read this article at

      ScienceOpenPublisher
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background Native T1 mapping is a cardiovascular magnetic resonance (CMR) technique that associates with markers of fibrosis and strain in hemodialysis patients. The reproducibility of T1 mapping in hemodialysis patients, prone to changes in fluid status, is unknown. Accurate quantification of myocardial fibrosis in this population has prognostic potential. Methods Using 3 Tesla CMR, we report the results of 1) the inter-study, inter-observer and intra-observer reproducibility of native T1 mapping in 10 hemodialysis patients; 2) inter-study reproducibility of left ventricular (LV) structure and function in 10 hemodialysis patients; 3) the agreement of native T1 map and native T1 phantom analyses between two centres in 20 hemodialysis patients; 4) the effect of changes in markers of fluid status on native T1 values in 10 hemodialysis patients. Results Inter-study, inter-observer and intra-observer variability of native T1 mapping were excellent with co-efficients of variation (CoV) of 0.7, 0.3 and 0.4% respectively. Inter-study CoV for LV structure and function were: LV mass = 1%; ejection fraction = 1.1%; LV end-diastolic volume = 5.2%; LV end-systolic volume = 5.6%. Inter-centre variability of analysis techniques were excellent with CoV for basal and mid-native T1 slices between 0.8–1.2%. Phantom analyses showed comparable native T1 times between centres, despite different scanners and acquisition sequences (centre 1: 1192.7 ± 7.5 ms, centre 2: 1205.5 ± 5 ms). For the 10 patients who underwent inter-study testing, change in body weight (Δweight) between scans correlated with change in LV end-diastolic volume (ΔLVEDV) (r = 0.682;P = 0.03) representing altered fluid status between scans. There were no correlations between change in native T1 between scans (ΔT1) and ΔLVEDV or Δweight (P > 0.6). Linear regression confirmed ΔT1 was unaffected by ΔLVEDV or Δweight (P > 0.59). Conclusions Myocardial native T1 is reproducible in HD patients and unaffected by changes in fluid status at the levels we observed. Native T1 mapping is a potential imaging biomarker for myocardial fibrosis in patients with end-stage renal disease. Electronic supplementary material The online version of this article (doi:10.1186/s12968-017-0337-7) contains supplementary material, which is available to authorized users.

          Related collections

          Most cited references43

          • Record: found
          • Abstract: found
          • Article: not found

          Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart.

          A novel pulse sequence scheme is presented that allows the measurement and mapping of myocardial T1 in vivo on a 1.5 Tesla MR system within a single breath-hold. Two major modifications of conventional Look-Locker (LL) imaging are introduced: 1) selective data acquisition, and 2) merging of data from multiple LL experiments into one data set. Each modified LL inversion recovery (MOLLI) study consisted of three successive LL inversion recovery (IR) experiments with different inversion times. We acquired images in late diastole using a single-shot steady-state free-precession (SSFP) technique, combined with sensitivity encoding to achieve a data acquisition window of < 200 ms duration. We calculated T1 using signal intensities from regions of interest and pixel by pixel. T1 accuracy at different heart rates derived from simulated ECG signals was tested in phantoms. T1 estimates showed small systematic error for T1 values from 191 to 1196 ms. In vivo T1 mapping was performed in two healthy volunteers and in one patient with acute myocardial infarction before and after administration of Gd-DTPA. T1 values for myocardium and noncardiac structures were in good agreement with values available from the literature. The region of infarction was clearly visualized. MOLLI provides high-resolution T1 maps of human myocardium in native and post-contrast situations within a single breath-hold. Copyright 2004 Wiley-Liss, Inc.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found

            Noncontrast T1 mapping for the diagnosis of cardiac amyloidosis.

            This study sought to explore the potential role of noncontrast myocardial T1 mapping for detection of cardiac involvement in patients with primary amyloid light-chain (AL) amyloidosis. Cardiac involvement carries a poor prognosis in systemic AL amyloidosis. Late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) is useful for the detection of cardiac amyloid, but characteristic LGE patterns do not always occur or they appear late in the disease. Noncontrast characterization of amyloidotic myocardium with T1 mapping may improve disease detection. Furthermore, quantitative assessment of myocardial amyloid load would be of great value. Fifty-three AL amyloidosis patients (14 with no cardiac involvement, 11 with possible involvement, and 28 with definite cardiac involvement based on standard biomarker and echocardiographic criteria) underwent CMR (1.5-T) including noncontrast T1 mapping (shortened modified look-locker inversion recovery [ShMOLLI] sequence) and LGE imaging. These were compared with 36 healthy volunteers and 17 patients with aortic stenosis and a comparable degree of left ventricular hypertrophy as the cardiac amyloid patients. Myocardial T1 was significantly elevated in cardiac AL amyloidosis patients (1,140 ± 61 ms) compared to normal subjects (958 ± 20 ms, p < 0.001) and patients with aortic stenosis (979 ± 51 ms, p < 0.001). Myocardial T1 was increased in AL amyloid even when cardiac involvement was uncertain (1,048 ± 48 ms) or thought absent (1,009 ± 31 ms). A noncontrast myocardial T1 cutoff of 1,020 ms yielded 92% accuracy for identifying amyloid patients with possible or definite cardiac involvement. In the AL amyloidosis cohort, there were significant correlations between myocardial T1 time and indices of systolic and diastolic dysfunction. Noncontrast T1 mapping has high diagnostic accuracy for detecting cardiac AL amyloidosis, correlates well with markers of systolic and diastolic dysfunction, and is potentially more sensitive for detecting early disease than LGE imaging. Elevated myocardial T1 may represent a direct marker of cardiac amyloid load. Further studies are needed to assess the prognostic significance of T1 elevation. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold

              Background T1 mapping allows direct in-vivo quantitation of microscopic changes in the myocardium, providing new diagnostic insights into cardiac disease. Existing methods require long breath holds that are demanding for many cardiac patients. In this work we propose and validate a novel, clinically applicable, pulse sequence for myocardial T1-mapping that is compatible with typical limits for end-expiration breath-holding in patients. Materials and methods The Shortened MOdified Look-Locker Inversion recovery (ShMOLLI) method uses sequential inversion recovery measurements within a single short breath-hold. Full recovery of the longitudinal magnetisation between sequential inversion pulses is not achieved, but conditional interpretation of samples for reconstruction of T1-maps is used to yield accurate measurements, and this algorithm is implemented directly on the scanner. We performed computer simulations for 100 ms
                Bookmark

                Author and article information

                Journal
                Journal of Cardiovascular Magnetic Resonance
                J Cardiovasc Magn Reson
                Springer Science and Business Media LLC
                1532-429X
                December 2017
                February 27 2017
                December 2017
                : 19
                : 1
                Article
                10.1186/s12968-017-0337-7
                88df7fb9-5e6d-4971-b68e-e6d0429f14ef
                © 2017
                History

                Comments

                Comment on this article