Inviting an author to review:
Find an author and click ‘Invite to review selected article’ near their name.
Search for authorsSearch for similar articles
27
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Platelet Aggregometry Testing: Molecular Mechanisms, Techniques and Clinical Implications

      International Journal of Molecular Sciences
      MDPI

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references146

          • Record: found
          • Abstract: found
          • Article: not found

          Comparison of platelet function tests in predicting clinical outcome in patients undergoing coronary stent implantation.

          Context High on-treatment platelet reactivity is associated with atherothrombotic events following coronary stent implantation. Objective To evaluate the capability of multiple platelet function tests to predict clinical outcome. Design, Setting, and Patients Prospective, observational, single-center cohort study of 1069 consecutive patients taking clopidogrel undergoing elective coronary stent implantation between December 2005 and December 2007. On-treatment platelet reactivity was measured in parallel by light transmittance aggregometry, Verify Now P2Y12 and Platelet works assays, and the IMPACT-R and the platelet function analysis system (PFA-100) (with the Dade PFA collagen/adenosine diphosphate (ADP) cartridge and Innovance PFA P2Y). Cutoff values for high on-treatment platelet reactivity were established by receiver operating characteristic curve (ROC) analysis. Main Outcome Measurement The primary end point was defined as a composite of all-cause death, nonfatal acute myocardial infarction, stent thrombosis, and ischemic stroke. The primary safety end point included TIMI (Thrombolysis In Myocardial Infarction) criteria major and minor bleeding. Results Kaplan-Meier analysis demonstrated that at 1-year follow-up, the primary end point occurred more frequently in patients with high on-treatment platelet reactivity when assessed by light transmittance aggregometry (52 [11.7%; 95% confidence interval {CI}, 8.9%-15.0%] vs 36 [6.0%;95%CI, 4.2%-8.2%] P.001; n=1049),Verify Now (54 [13.3%; 95% CI, 10.2%-17.0%] vs 37 [5.7%; 95% CI, 4.1%-7.8%]P.001; n=1052), Platelet works (33 [12.6%; 95% CI, 8.8%-17.2%] vs 21 [6.1%;95% CI, 3.8%-9.2%] P=.005; n=606), and Innovance PFA P2Y (18 [12.2%; 95%CI; 7.4%-18.6%] vs 28 [6.3%; 95% CI, 4.3%-8.9%] P=.02; n=588). ROC-curve analysis demonstrated that light transmittance aggregometry (area under the curve[AUC], 0.63; 95% CI, 0.58-0.68), Verify Now (AUC, 0.62; 95% CI, 0.57-0.67), and Platelet works (AUC, 0.61; 95% CI, 0.53-0.69) had modest ability to discriminate between patients with and without primary end point at 1-year follow-up. The IMPACT-R(n=905) and the Siemens PFA Collagen/ADP (n=812) were unable to discriminate between patients with and without the primary end point at 1-year follow-up (all AUCs included 0.50 in the CI). None of the tests identified patients at risk for bleeding. Conclusions Of the platelet function tests assessed, light transmittance aggregometry,Verify Now, Platelet works, and Innovance PFA P2Y were significantly associated with the primary end point. However, the predictive accuracy of these 4 tests was only modest. None of the tests provided accurate prognostic information to identify patients at higher risk of bleeding following stent implantation. Trial Registration clinical trials.gov Identifier: NCT00352014 [corrected].
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Calcium signaling in platelets.

            Agonist-induced elevation in cytosolic Ca2+ concentrations is essential for platelet activation in hemostasis and thrombosis. It occurs through Ca2+ release from intracellular stores and Ca2+ entry through the plasma membrane (PM). Ca2+ store release is a well-established process involving phospholipase (PL)C-mediated production of inositol-1,4,5-trisphosphate (IP3), which in turn releases Ca2+ from the intracellular stores through IP3 receptor channels. In contrast, the mechanisms controlling Ca2+ entry and the significance of this process for platelet activation have been elucidated only very recently. In platelets, as in other non-excitable cells, the major way of Ca2+ entry involves the agonist-induced release of cytosolic sequestered Ca2+ followed by Ca2+ influx through the PM, a process referred to as store-operated calcium entry (SOCE). It is now clear that stromal interaction molecule 1 (STIM1), a Ca2+ sensor molecule in intracellular stores, and the four transmembrane channel protein Orai1 are the key players in platelet SOCE. The other major Ca2+ entry mechanism is mediated by the direct receptor-operated calcium (ROC) channel, P2X1. Besides these, canonical transient receptor potential channel (TRPC) 6 mediates Ca2+ entry through the PM. This review summarizes the current knowledge of platelet Ca2+ homeostasis with a focus on the newly identified Ca2+ entry mechanisms.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Coagulation monitoring: current techniques and clinical use of viscoelastic point-of-care coagulation devices.

              Perioperative monitoring of blood coagulation is critical to better understand causes of hemorrhage, to guide hemostatic therapies, and to predict the risk of bleeding during the consecutive anesthetic or surgical procedures. Point-of-care (POC) coagulation monitoring devices assessing the viscoelastic properties of whole blood, i.e., thrombelastography, rotation thrombelastometry, and Sonoclot analysis, may overcome several limitations of routine coagulation tests in the perioperative setting. The advantage of these techniques is that they have the potential to measure the clotting process, starting with fibrin formation and continue through to clot retraction and fibrinolysis at the bedside, with minimal delays. Furthermore, the coagulation status of patients is assessed in whole blood, allowing the plasmatic coagulation system to interact with platelets and red cells, and thereby providing useful additional information on platelet function. Viscoelastic POC coagulation devices are increasingly being used in clinical practice, especially in the management of patients undergoing cardiac and liver surgery. Furthermore, they provide useful information in a large variety of clinical scenarios, e.g., massive hemorrhage, assessment of hypo- and hypercoagulable states, guiding pro- and anticoagulant therapies, and in diagnosing of a surgical bleeding. A surgical etiology of bleeding has to be considered when viscoelastic test results are normal. In summary, viscoelastic POC coagulation devices may help identify the cause of bleeding and guide pro- and anticoagulant therapies. To ensure optimal accuracy and performance, standardized procedures for blood sampling and handling, strict quality controls and trained personnel are required.
                Bookmark

                Author and article information

                Journal
                10.3390/ijms18081803
                https://creativecommons.org/licenses/by/4.0/

                Comments

                Comment on this article