      Intelligent wireless theranostic contact lens for electrical sensing and regulation of intraocular pressure

      research-article

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Engineering wearable devices that can wirelessly track intraocular pressure and offer feedback-medicine administrations are highly desirable for glaucoma treatments, yet remain challenging due to issues of limited sizes, wireless operations, and wireless cross-coupling. Here, we present an integrated wireless theranostic contact lens for in situ electrical sensing of intraocular pressure and on-demand anti-glaucoma drug delivery. The wireless theranostic contact lens utilizes a highly compact structural design, which enables high-degreed integration and frequency separation on the curved and limited surface of contact lens. The wireless intraocular pressure sensing modulus could ultra-sensitively detect intraocular pressure fluctuations, due to the unique cantilever configuration design of capacitive sensing circuit. The drug delivery modulus employs an efficient wireless power transfer circuit, to trigger delivery of anti-glaucoma drug into aqueous chamber via iontophoresis. The minimally invasive, smart, wireless and theranostic features endow the wireless theranostic contact lens as a highly promising system for glaucoma treatments.

          Abstract

          Towards intelligent treatment for glaucoma, here authors demonstrate integrated wireless theranostic contact lenses for in situ electrical sensing of intraocular pressure and on demand anti-glaucoma drug delivery.

          Related collections

          Most cited references48

          • Record: found
          • Abstract: found
          • Article: not found

          Multifunctional wearable devices for diagnosis and therapy of movement disorders.

          Wearable systems that monitor muscle activity, store data and deliver feedback therapy are the next frontier in personalized medicine and healthcare. However, technical challenges, such as the fabrication of high-performance, energy-efficient sensors and memory modules that are in intimate mechanical contact with soft tissues, in conjunction with controlled delivery of therapeutic agents, limit the wide-scale adoption of such systems. Here, we describe materials, mechanics and designs for multifunctional, wearable-on-the-skin systems that address these challenges via monolithic integration of nanomembranes fabricated with a top-down approach, nanoparticles assembled by bottom-up methods, and stretchable electronics on a tissue-like polymeric substrate. Representative examples of such systems include physiological sensors, non-volatile memory and drug-release actuators. Quantitative analyses of the electronics, mechanics, heat-transfer and drug-diffusion characteristics validate the operation of individual components, thereby enabling system-level multifunctionalities.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            A graphene-based electrochemical device with thermoresponsive microneedles for diabetes monitoring and therapy.

            Owing to its high carrier mobility, conductivity, flexibility and optical transparency, graphene is a versatile material in micro- and macroelectronics. However, the low density of electrochemically active defects in graphene synthesized by chemical vapour deposition limits its application in biosensing. Here, we show that graphene doped with gold and combined with a gold mesh has improved electrochemical activity over bare graphene, sufficient to form a wearable patch for sweat-based diabetes monitoring and feedback therapy. The stretchable device features a serpentine bilayer of gold mesh and gold-doped graphene that forms an efficient electrochemical interface for the stable transfer of electrical signals. The patch consists of a heater, temperature, humidity, glucose and pH sensors and polymeric microneedles that can be thermally activated to deliver drugs transcutaneously. We show that the patch can be thermally actuated to deliver Metformin and reduce blood glucose levels in diabetic mice.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Glaucoma.

              Glaucoma is a heterogeneous group of diseases characterised by cupping of the optic nerve head and visual-field damage. It is the most frequent cause of irreversible blindness worldwide. Progression usually stops if the intraocular pressure is lowered by 30-50% from baseline. Its worldwide age-standardised prevalence in the population aged 40 years or older is about 3·5%. Chronic forms of glaucoma are painless and symptomatic visual-field defects occur late. Early detection by ophthalmological examination is mandatory. Risk factors for primary open-angle glaucoma-the most common form of glaucoma-include older age, elevated intraocular pressure, sub-Saharan African ethnic origin, positive family history, and high myopia. Older age, hyperopia, and east Asian ethnic origin are the main risk factors for primary angle-closure glaucoma. Glaucoma is diagnosed using ophthalmoscopy, tonometry, and perimetry. Treatment to lower intraocular pressure is based on topical drugs, laser therapy, and surgical intervention if other therapeutic modalities fail to prevent progression.
                Bookmark

                Author and article information

                Contributors
                xiexi27@mail.sysu.edu.cn
                Journal
                Nat Commun
                Nat Commun
                Nature Communications
                Nature Publishing Group UK (London )
                2041-1723
                17 May 2022
                17 May 2022
                2022
                : 13
                : 2556
                Affiliations
                [1 ]GRID grid.12981.33, ISNI 0000 0001 2360 039X, State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, , Sun Yat-Sen University, ; Guangzhou, 510006 China
                [2 ]GRID grid.12981.33, ISNI 0000 0001 2360 039X, State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, , Sun Yat-Sen University, ; Guangzhou, 510006 China
                [3 ]GRID grid.412601.0, ISNI 0000 0004 1760 3828, Department of Cardiology, , the First Affiliated Hospital of Jinan University, ; Guangzhou, 510630 China
                [4 ]GRID grid.12981.33, ISNI 0000 0001 2360 039X, School of Biomedical Engineering, , Sun Yat-Sen University, ; Guangzhou, 510006 China
                [5 ]GRID grid.12981.33, ISNI 0000 0001 2360 039X, The First Affiliated Hospital of Sun Yat-Sen University, , Sun Yat-Sen University, ; Guangzhou, 510006 China
                Author information
                http://orcid.org/0000-0001-7406-8444
                Article
                29860
                10.1038/s41467-022-29860-x
                9114010
                35581184
                d94f05da-8ff8-420a-829e-7e0defaf1944
                © The Author(s) 2022

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 26 October 2021
                : 22 March 2022
                Funding
                Funded by: FundRef https://doi.org/10.13039/501100001809, National Natural Science Foundation of China (National Science Foundation of China);
                Award ID: 32171399
                Award ID: 32171335
                Award ID: 61901535
                Award ID: 31900954
                Award ID: 62104264
                Award Recipient :
                Categories
                Article
                Custom metadata
                © The Author(s) 2022

                Uncategorized
                biomedical engineering,electrical and electronic engineering,diagnosis,biotechnology,sensors and probes