      Flow Diversion for Intracranial Aneurysms Beyond the Circle of Willis

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background: Few reports have shown the therapeutic outcomes of flow diversion (FD) for intracranial aneurysms beyond the circle of Willis, and the efficacy of this technique remains unclear.

          Materials and methods: A retrospective study was performed on 22 consecutive patients, diagnosed with intracranial aneurysms beyond the circle of Willis, and treated with pipeline embolization device (PED) (Medtronic, Irvine, California, USA) between January 2015 and December 2019.

          Result: The 22 patients were between 16 and 66 years old (mean 44.5 ± 12.7 years), and six patients were male (27.3%, 6/22). Twenty-two patients had 23 aneurysms. The 23 aneurysms were 3–25 mm in diameter (12.2 ± 7.1 mm on average). The diameter of the parent artery was 1.3–3.0 mm (2.0 ± 0.6 mm on average). The 23 aneurysms were located as follows: 17 (73.9%, 17/23) were in the anterior circulation, and 6 (26.1%, 6/23) were in the posterior circulation. PED deployment was technically successful in all cases. Two overlapping PEDs were used to cover the aneurysm neck in 3 cases. One PED was used to overlap the two tandem P1 and P2 aneurysms. Other cases were treated with single PED. Coil assistance was used to treat 7 aneurysms, including 4 recurrent aneurysms and 3 new cases requiring coiling assistance during PED deployment. There were no cases of complications during PED deployment. All patients were available at the follow-up (mean, 10.9 ± 11.4 months). All patients presented with a modified Rankin Score (mRS) of 0. During angiographic follow-up, complete embolization was observed in 22 aneurysms in 21 patients, and one patient had subtotal embolization with the prolongation of stasis in the arterial phase.

          Conclusion: PED deployment for intracranial aneurysms beyond the circle of Willis is feasible and effective, with high rates of aneurysm occlusion.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial.

          To evaluate the safety and effectiveness of the Pipeline Embolization Device (PED; ev3/Covidien, Irvine, Calif) in the treatment of complex intracranial aneurysms. The Pipeline for Uncoilable or Failed Aneurysms is a multicenter, prospective, interventional, single-arm trial of PED for the treatment of uncoilable or failed aneurysms of the internal carotid artery. Institutional review board approval of the HIPAA-compliant study protocol was obtained from each center. After providing informed consent, 108 patients with recently unruptured large and giant wide-necked aneurysms were enrolled in the study. The primary effectiveness endpoint was angiographic evaluation that demonstrated complete aneurysm occlusion and absence of major stenosis at 180 days. The primary safety endpoint was occurrence of major ipsilateral stroke or neurologic death at 180 days. PED placement was technically successful in 107 of 108 patients (99.1%). Mean aneurysm size was 18.2 mm; 22 aneurysms (20.4%) were giant (>25 mm). Of the 106 aneurysms, 78 met the study's primary effectiveness endpoint (73.6%; 95% posterior probability interval: 64.4%-81.0%). Six of the 107 patients in the safety cohort experienced a major ipsilateral stroke or neurologic death (5.6%; 95% posterior probability interval: 2.6%-11.7%). PED offers a reasonably safe and effective treatment of large or giant intracranial internal carotid artery aneurysms, demonstrated by high rates of complete aneurysm occlusion and low rates of adverse neurologic events; even in aneurysms failing previous alternative treatments.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found

            Aneurysm Study of Pipeline in an Observational Registry (ASPIRe)

            Background and Objective: Few prospective studies exist evaluating the safety and efficacy of the Pipeline Embolization Device (PED) in the treatment of intracranial aneurysms. The Aneurysm Study of Pipeline In an observational Registry (ASPIRe) study prospectively analyzed rates of complete aneurysm occlusion and neurologic adverse events following PED treatment of intracranial aneurysms. Materials and Methods: We performed a multicenter study prospectively evaluating patients with unruptured intracranial aneurysms treated with PED. Primary outcomes included (1) spontaneous rupture of the Pipeline-treated aneurysm; (2) spontaneous nonaneurysmal intracranial hemorrhage (ICH); (3) acute ischemic stroke; (4) parent artery stenosis, and (5) permanent cranial neuropathy. Secondary endpoints were (1) treatment success and (2) morbidity and mortality at the 6-month follow-up. Vascular imaging was evaluated at an independent core laboratory. Results: One hundred and ninety-one patients with 207 treated aneurysms were included in this registry. The mean aneurysm size was 14.5 ± 6.9 mm, and the median imaging follow-up was 7.8 months. Twenty-four aneurysms (11.6%) were small, 162 (78.3%) were large and 21 (10.1%) were giant. The median clinical follow-up time was 6.2 months. The neurological morbidity rate was 6.8% (13/191), and the neurological mortality rate was 1.6% (3/191). The combined neurological morbidity/mortality rate was 6.8% (13/191). The most common adverse events were ischemic stroke (4.7%, 9/191) and spontaneous ICH (3.7%, 7/191). The complete occlusion rate at the last follow-up was 74.8% (77/103). Conclusions: Our prospective postmarket study confirms that PED treatment of aneurysms in a heterogeneous patient population is safe with low rates of neurological morbidity and mortality. Patients with angiographic follow-up had complete occlusion rates of 75% at 8 months.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Stent-assisted coiling in endovascular treatment of 500 consecutive cerebral aneurysms with long-term follow-up.

              Stent-assisted coil embolization has become one of the most preferred techniques in the treatment of wide-neck intracranial aneurysms; however, long-term patency and safety of the self-expanding neurostents and their role in durability of the endovascular treatment has remained ambiguous. We sought to retrospectively examine the long-term results of self-expanding stent usage in conjunction with coil embolization in treatment of wide-neck cerebral aneurysms. We coiled 500 wide-neck cerebral aneurysms with different types of self-expanding neurostent assistance in 468 patients. Patient and aneurysm characteristics, pharmacologic therapy protocol, complications, and initial occlusion grades were analyzed. Patients underwent angiographic follow-up at 6 months to 7 years after treatment. DSA or MRA images of all patients were analyzed to assess the occlusion rate of aneurysms and patency of the parent artery. Enterprise (n = 340), Solitaire (n = 98), Wingspan (n = 41), LEO (n = 16), and Neuroform (n = 5) stent systems were used in this series. Stent-related thromboembolic events occurred in 21 patients and intraoperative rupture occurred in 4 patients. Initially, complete occlusion was achieved in 42.2% of the aneurysms, and, according to the last follow-up data, the rate had progressed to 90.8%. Recanalization rate at 6 months was 8%, whereas the late recanalization rate was 2%. The use of stents in endovascular treatment provides high rates of complete occlusion and low rates of recurrence at a long-term follow-up study.
                Bookmark

                Author and article information

                Contributors
                Journal
                Front Neurol
                Front Neurol
                Front. Neurol.
                Frontiers in Neurology
                Frontiers Media S.A.
                1664-2295
                31 May 2021
                2021
                : 12
                : 674966
                Affiliations
                [1] 1Department of Neurosurgery, The First Hospital of Jilin University , Changchun, China
                [2] 2Department of Neurosurgery, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University , Beijing, China
                Author notes

                Edited by: Hong-Qi Zhang, Capital Medical University, China

                Reviewed by: Adam A. Dmytriw, Brigham and Women's Hospital and Harvard Medical School, United States; Xinjian Yang, Capital Medical University, China

                *Correspondence: Xianli Lv lvxianli000@ 123456163.com

                This article was submitted to Endovascular and Interventional Neurology, a section of the journal Frontiers in Neurology

                Article
                10.3389/fneur.2021.674966
                8200461
                34135853
                005d777b-0114-4df4-baf0-1714fbeac7dd
                Copyright © 2021 Yu and Lv.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 02 March 2021
                : 28 April 2021
                Page count
                Figures: 2, Tables: 1, Equations: 0, References: 21, Pages: 6, Words: 3790
                Categories
                Neurology
                Original Research

                Neurology
                pipeline embolization device,endovascular treatment,circle of willis,distal aneurysm,complex aneurysm

                Comments

                Comment on this article