          All aberrations produced inside a biospecimen can degrade the quality of a three-dimensional image in two-photon excitation laser scanning microscopy. Previously, we developed a transmissive liquid-crystal device to correct spherical aberrations that improved the image quality of a fixed-mouse-brain slice treated with an optical clearing reagent. In this study, we developed a transmissive device that corrects primary coma aberration and astigmatism. The motivation for this study is that asymmetric aberration can be induced by the shape of a biospecimen and/or by a complicated refractive-index distribution in a sample; this can considerably degrade optical performance even near the sample surface. The device’s performance was evaluated by observing fluorescence beads. The device was inserted between the objective lens and microscope revolver and succeeded in improving the spatial resolution and fluorescence signal of a bead image that was originally degraded by asymmetric aberration. Finally, we implemented the device for observing a fixed whole mouse brain with a sloping surface shape and complicated internal refractive-index distribution. The correction with the device improved the spatial resolution and increased the fluorescence signal by ?2.4×. The device can provide a simple approach to acquiring higher-quality images of biospecimens.

          Related collections

          Author and article information

          Journal
          J Biomed Opt
          Journal of biomedical optics
          SPIE-Intl Soc Optical Eng
          1560-2281
          1083-3668
          December 01 2016
          : 21
          : 12
          Affiliations
          [1 ] Hokkaido University, Graduate School of Information Science and Technology, N14W9, Kita-Ward, Sapporo, Hokkaido 060-0814, JapanbHokkaido University, Research Institute for Electronic Science, N20W10, Kita-Ward, Sapporo, Hokkaido 001-0020, JapancCitizen Holdings Co., Ltd., 840, Shimotomi, Tokorozawa, Saitama 359-8511, Japan.
          [2 ] Hokkaido University, Research Institute for Electronic Science, N20W10, Kita-Ward, Sapporo, Hokkaido 001-0020, Japan.
          [3 ] Hokkaido University, Graduate School of Information Science and Technology, N14W9, Kita-Ward, Sapporo, Hokkaido 060-0814, JapanbHokkaido University, Research Institute for Electronic Science, N20W10, Kita-Ward, Sapporo, Hokkaido 001-0020, Japan.
          [4 ] Citizen Holdings Co., Ltd., 840, Shimotomi, Tokorozawa, Saitama 359-8511, Japan.
          Article
          2553354
          10.1117/1.JBO.21.12.121503
          27624000
          01286c0d-4fdc-449c-aaf5-6532b866cc22
          History

          Comments

          Comment on this article