6
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Diagnostic performance of multifocal photopic negative response, pattern electroretinogram and optical coherence tomography in glaucoma.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The photopic negative response of the electroretinogram reflects retinal ganglion cell function and consequently aids diagnosis of optic nerve diseases including glaucoma. In this study, we assessed the efficacy of stimulation parameters for electroretinographic recordings of the multifocal photopic negative response (mfPhNR) for the detection of glaucoma and compared the diagnostic accuracy of electrophysiological, structural and functional measures of glaucoma. We compared the diagnostic performance of the mfPhNR for 6 different stimulation rates in a cohort of 24 controls, 10 glaucoma suspects (GLAS ) and 16 glaucoma participants (GLAG). A cross-modal comparison of the mfPhNR/b wave ratio was performed with the pattern electroretinogram (PERG), and the peripapillary retinal nerve fiber layer (pRNFL) thickness. These analyses were based on area under curves (AUC) obtained from receiver-operating-characteristics (ROC) and step-wise regression analyses. We found that compared to the other mfPhNR-conditions, the PhNR/b-wave ratio for the fastest stimulation condition had the highest AUC for GLAS (0.84, P = 0.008, 95%CI: 0.71- 0.98), while the other modalities, i.e., PERG-amplitude and pRNFL had AUCs of 0.78 (P= 0.039), and 0.74 (P < 0.05), respectively. For GLAG , the respective AUCs were 0.78 (P= 0.004), 0.85 (P< 0.001) and 0.87 (P< 0.001). pRNFL was the significant predictor for both mfPhNR/b-wave ratio [t (48) = 4, P = 0.0002] and for PERG amplitude [t (48) = 3.4, P = 0.001]. In conclusion, fast mfPhNR protocols outperform other multifocal PhNR protocols in the identification of glaucomatous damage especially for GLAS and thus aid the early detection of glaucoma, indicating its value as a surrogate marker of early stage ganglion cell dysfunction.

          Related collections

          Author and article information

          Journal
          Exp Eye Res
          Experimental eye research
          Elsevier BV
          1096-0007
          0014-4835
          Nov 2020
          : 200
          Affiliations
          [1 ] Department of Ophthalmology, Otto-von-Guericke University, Magdeburg, Germany.
          [2 ] Department of Ophthalmology, Otto-von-Guericke University, Magdeburg, Germany; Center for Behavioral Brain Sciences, Magdeburg, Germany. Electronic address: michael.hoffmann@med.ovgu.de.
          Article
          S0014-4835(20)30500-5
          10.1016/j.exer.2020.108242
          32926894
          04013e19-a834-4032-a2fb-573b32415e90
          History

          Multifocal,Glaucoma,ERG,Photopic negative response,Retinal ganglion cells,Pattern electroretinogram

          Comments

          Comment on this article