          Abstract

          Toluene is widely used in industrial and laboratory applications and in many countries is related with social problems of abuse. Unaltered urinary toluene was introduced as a bioindicator of occupational exposure to the solvent, but its analysis presents difficulties due to the low levels of the compound excreted in urine. A gas-chromatography/flame ionization method for toluene in urine is described using headspace solid-phase microextraction and establishing the better conditions for two different extracting phases: polydimethylsiloxane (PDMS) and carboxen-PDMS. The carboxen-PDMS fiber showed lower quantifying limit (12.5 ng mL-1), better extraction efficiency (up to 28.1%) and repeatability (CV < 4.9%) than PDMS coating. The method was applied to analysis of toluene in urine of workers from car repair shops exposed to low solvent levels.

          Translated abstract

          O tolueno é amplamente usado em aplicações industriais e de laboratório, e está relacionado a problemas de abuso social. O tolueno inalterado em urina é considerado um bioindicador mais específico da exposição ocupacional ao solvente. Entretanto, sua análise apresenta algumas dificuldades de ordem analítica, relacionadas aos baixos valores detectados em urina. Nesta pesquisa foi desenvolvido um método cromatográfico em fase gasosa com detecção por ionização em chama e usando-se a técnica de headspace-microextração em fase sólida em dois diferentes tipos de fibra: polidimetilsiloxana (PDMS) e carboxen-PDMS. Após a otimização das variáveis dos processos de extração, o uso da fibra carboxen-PDMS demonstrou menor limite de quantificação (12,5 ng mL-1), melhor eficiência de extração (até 28,1%) e repetibilidade (CV < 4,9%) com relação à de PDMS. O método foi aplicado na análise de tolueno em urina de trabalhadores expostos a baixos teores do solvente em oficinas de reparo de veículos.

          Related collections

          Most cited references27

          • Record: found
          • Abstract: not found
          • Article: not found

          Solid Phase Microextraction: Theory and Practice

            Bookmark
            • Record: found
            • Abstract: not found
            • Book: not found

            Solid Phase Micro-extraction Theory and Practice

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Anuários da Indústria Química Brasileira

              (1993)
                Bookmark

                Author and article information

                Journal
                jbchs
                Journal of the Brazilian Chemical Society
                J. Braz. Chem. Soc.
                Sociedade Brasileira de Química (São Paulo, SP, Brazil )
                0103-5053
                1678-4790
                2008
                : 19
                : 6
                : 1201-1206
                Affiliations
                [01] Alfenas MG orgnameUniversidade Federal de Alfenas orgdiv1Laboratório de Análises Toxicológicas Brazil
                Article
                S0103-50532008000600022 S0103-5053(08)01900622
                10.1590/S0103-50532008000600022
                043ca687-71c0-4a42-bb5a-2789008107b5

                This work is licensed under a Creative Commons Attribution 4.0 International License.

                History
                : 25 July 2008
                : 12 April 2007
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 24, Pages: 6
                Product

                SciELO Brazil

                Self URI: Full text available only in PDF format (EN)
                Categories
                Articles

                urinary toluene,HS-SPME,sample preparation,gas-chromatography

                Comments

                Comment on this article