      Development and calibration of a modifiable passive sampler for monitoring atmospheric tritiated water vapor in different environments.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Anthropogenic release of tritium from nuclear facilities is expected to increase significantly in the coming decades, which may cause radiation exposure to humans through the contamination of water and food chains. It is necessary and urgent to acquire detailed information about tritium in various environments for studying its behavior and assessing the potential radiation risk. In the atmosphere, although the passive sampling technique provides a low-cost and convenient way to characterize the dynamics of tritiated water vapor (HTO), a single, simple sampler configuration makes it difficult to collect sufficient and representative samples within the expected period from different environments. In this study, we systematically studied the impacts of sampler configurations on sampling performance and proposed a modifiable sampler design by scaling sampler geometry and adjusting absorbent to achieve different monitoring demands. The samplers were subsequently deployed at five sites in China and Germany for the field calibration and the measured results exhibited a good agreement between the adsorption process obtained in sites corrected with diffusion coefficient and the one calibrated in Shanghai. This suggests the feasibility of predicting sampling performance in the field based on known data. Finally, we developed a strategy for sampler modification and selection in different environments and demonstrated that using easily obtainable environmental data, our sampler can be optimized for any area without any time-consuming preliminary experiments. This work provides a scientific basis for establishing high-resolution atmospheric HTO database and expands the conventional empirical sampler design paradigm by demonstrating the feasibility of using quantitative indices for sampler performance customization.

          Related collections

          Author and article information

          Journal
          Environ Int
          Environment international
          Elsevier BV
          1873-6750
          0160-4120
          Nov 2022
          : 169
          Affiliations
          [1 ] Institute of Radioecology and Radiation Protection, Leibniz Universität Hannover, 30419 Hannover, Germany; Institute of Radiation Medicine, Fudan University, Shanghai 200032, China.
          [2 ] Institute of Radioecology and Radiation Protection, Leibniz Universität Hannover, 30419 Hannover, Germany; TU Wien, Institute of Applied Synthetic Chemistry & TRIGA Center Atominstitut, 1060 Vienna, Austria.
          [3 ] Institute of Radiation Medicine, Fudan University, Shanghai 200032, China.
          [4 ] Institute of Radioecology and Radiation Protection, Leibniz Universität Hannover, 30419 Hannover, Germany.
          [5 ] Shanghai Institute of Measurement and Testing Technology, Shanghai 201203, China.
          [6 ] Institute of Inorganic Chemistry, Leibniz Universität Hannover, 30167 Hannover, Germany.
          [7 ] Institute of Radiation Medicine, Fudan University, Shanghai 200032, China. Electronic address: bochenFYS@fudan.edu.cn.
          Article
          S0160-4120(22)00432-9
          10.1016/j.envint.2022.107505
          36115249
          0489145f-e855-4693-bda4-9c3893448626
          History

          Passive sampler,Atmospheric monitoring,Tritium,Field calibration,Nuclear facilities,Radiation protection

          Comments