6
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Programa de evaluación de la veracidad de los análisis de laboratorio en la provincia Camagüey Translated title: Evaluation program of the truthfulness of the lab: analysis using values assigned in Camagüey province

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Camagüey ha realizado un trabajo estable en el Programa de Evaluación Externa de la Calidad; no obstante, la labor de capacitación, control y exigencia mantenida del centro coordinador, los promedios en índices de varianza han sido aceptables por lo que se reflexionó en la necesidad de detectar aquellos laboratorios que desvían la media consenso, aumentan la dispersión y causan falsos resultados en la evaluación y crearon las condiciones para la evaluación de la veracidad y lograr concordancia entre la media consenso establecida por el Programa de Evaluación de la Calidad (SECAL) y la media de referencia. Al procesar las muestras de forma paralela en los laboratorios, se consideraron aceptados los valores que se encuentran en el rango 3 desviaciones, estándar y rechazados, los que están fuera de rango, para los cálculos y la evaluación se utilizó la primera versión de un programa automatizado diseñado con este fin, en Delphi 3. En tres años de aplicado el programa en la provincia se ha obtenido un promedio de 70 % de resultados aceptados.

          Translated abstract

          Camagüey has performed an stable work in the Program of Quality External Evaluation, eventhough the capacitation labor, control and exigency maintained by the coordinating center, the variance index averages have been acceptable, so it was considerated the necessity of detecting those laboratories that deviate the mean consensus, increase dispersion and cause false result in the evaluation, thus the conditions were created for the evaluation of the truthfulness to achieve the agreement among the mean consensus established by the SECAL and the reference mean. For the evaluation of the truthfulness, the calculation of the mean and the standard desviation obtained was performed by the Coordinator Center laboratory was performed. When processing the samples parallely in the laboratories we consider accepted those values that are within range ± 3 standard deviations and rejected those out of this range. For calculations and evaluation the first version of an automated program design for this purpose in Dlphi 3, was used. After three years of having applied the program, a 70 % results accepted as average in the province, has been obtained.

          Related collections

          Most cited references15

          • Record: found
          • Abstract: not found
          • Book: not found

          Fundamentals of clinical chemistry

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Tecnología y Sociedad

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Data and information quality strategic plan

              C Bethell (2002)
                Bookmark

                Author and article information

                Contributors
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Journal
                amc
                Revista Archivo Médico de Camagüey
                AMC
                Editorial Ciencias Médicas Camagüey
                1025-0255
                June 2004
                : 8
                : 3
                : 45-51
                Affiliations
                [1 ] Instituto Superior de Ciencias Médicas Carlos J. Finlay. Camagüey, Cuba Cuba
                Article
                S1025-02552004000300006
                05ccfcaf-bed8-4efd-b852-fdd7b27d89a6

                http://creativecommons.org/licenses/by/4.0/

                History
                Product

                SciELO Cuba

                Self URI (journal page): http://scielo.sld.cu/scielo.php?script=sci_serial&pid=1025-0255&lng=en
                Categories
                MEDICINE, GENERAL & INTERNAL

                Internal medicine
                CLINICAL LABORATORY TECHNIQUES,QUALITY CONTROL,TÉCNICAS DE LABORATORIO CLÍNICO,CONTROL DE CALIDAD

                Comments

                Comment on this article