14
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Aneurisma toracoabdominal roto: modificação do circuito de perfusão visceral Translated title: Thoracoabdominal aneurysm rupture: a modification of the visceral perfusion circuit

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Paciente portador de aneurisma toracoabdominal (ATA) tipo lV, roto, submetido a tratamento cirúrgico utilizando perfusão visceral assistida por bomba centrífuga e oxigenador de membrana neonatal. Este circuito permite a perfusão visceral com sangue oxigenado, durante o período de isquemia, e infusão de volume rápido via venosa após a retirada da pinça.

          Translated abstract

          A patient with ruptured type IV thoracoabdominal aortic aneurysm (TAAA), underwent surgical treatment utilizing visceral perfusion assisted by a centrifugal pump and neonatal membrane oxygenator. This circuit allows visceral perfusion with oxygenated blood during the ischemic period and the fast infusion of intravenous volume after clamp removal.

          Related collections

          Most cited references8

          • Record: found
          • Abstract: found
          • Article: not found

          Selective visceral and renal perfusion in thoracoabdominal aneurysm repair.

          Whether or not selective visceral and renal perfusion during thoracoabdominal aortic aneurysm (TAAA) repair has a protective effect on visceral and renal function remains unknown. The aim of this study was to clarify if selective perfusion has such an effect.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Emergency thoracoabdominal aortic repair: clinical outcome

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Renal perfusion during thoracoabdominal aortic operations: cold crystalloid is superior to normothermic blood

                Bookmark

                Author and article information

                Contributors
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Journal
                rbccv
                Brazilian Journal of Cardiovascular Surgery
                Braz. J. Cardiovasc. Surg.
                Sociedade Brasileira de Cirurgia Cardiovascular (São José do Rio Preto )
                1678-9741
                December 2004
                : 19
                : 4
                : 413-416
                Affiliations
                [1 ] Universidade Estadual de Campinas Brazil
                Article
                S0102-76382004000400016
                10.1590/S0102-76382004000400016
                0fbca768-c533-4656-9e22-44d9d8a2fea9

                http://creativecommons.org/licenses/by/4.0/

                History
                Product

                SciELO Brazil

                Self URI (journal page): http://www.scielo.br/scielo.php?script=sci_serial&pid=0102-7638&lng=en
                Categories
                CARDIAC & CARDIOVASCULAR SYSTEMS
                SURGERY

                Surgery,Cardiovascular Medicine
                Aortic aneurysm, thoracic,Aortic aneurysm, abdominal,Perfusion,Infusion pumps,Aneurisma da aorta torácica,Aneurisma da aorta abdominal,Perfusão,Bombas de infusão

                Comments

                Comment on this article