          The current scale of public and private testing cannot be expected to meet the emerging need for higher levels of community-level and repeated screening of asymptomatic Canadians for SARS-CoV-2. Rapid point-of-care techniques are increasingly being offered to fill the gap in screening levels required to identify undiagnosed individuals with high viral loads. However, rapid, point-of-care tests often have lower sensitivity in practice. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) for SARS-CoV-2 has proven sensitive and specific and provides visual results in minutes. Using a commercially available kit for RT-LAMP and primer set targetting nucleocapsid (N), we tested a blinded set of 101 archived nasopharyngeal (NP) swab samples with known RT-PCR results. RT-LAMP reactions were incubated at 65 °C for 30 minutes, using heat-inactivated nasopharyngeal swab sample in viral transport medium, diluted tenfold in water, as input. RT-LAMP agreed with all RT-PCR defined negatives (N = 51), and all positives with cycle threshold (Ct) less than 20 (N = 24), 65% of positives with Ct between 20-30 (N = 17), and no positives with Ct greater than 30 (N = 9). RT-LAMP requires fewer and different core components, so may not compete directly with the mainline testing workflow, preserving precious central laboratory resources for those with the greatest need. Careful messaging must be provided when using less-sensitive tests, so that people are not falsely reassured by negative results, but this caveat must be weighed against the clear benefits of reliably identifying those with high levels of virus in prioritized samples at the point of care.

          Related collections

          Most cited references46

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR

          Background The ongoing outbreak of the recently emerged novel coronavirus (2019-nCoV) poses a challenge for public health laboratories as virus isolates are unavailable while there is growing evidence that the outbreak is more widespread than initially thought, and international spread through travellers does already occur. Aim We aimed to develop and deploy robust diagnostic methodology for use in public health laboratory settings without having virus material available. Methods Here we present a validated diagnostic workflow for 2019-nCoV, its design relying on close genetic relatedness of 2019-nCoV with SARS coronavirus, making use of synthetic nucleic acid technology. Results The workflow reliably detects 2019-nCoV, and further discriminates 2019-nCoV from SARS-CoV. Through coordination between academic and public laboratories, we confirmed assay exclusivity based on 297 original clinical specimens containing a full spectrum of human respiratory viruses. Control material is made available through European Virus Archive – Global (EVAg), a European Union infrastructure project. Conclusion The present study demonstrates the enormous response capacity achieved through coordination of academic and public laboratories in national and European research networks.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Genomic characterization of the 2019 novel human-pathogenic coronavirus isolated from a patient with atypical pneumonia after visiting Wuhan

            ABSTRACT A mysterious outbreak of atypical pneumonia in late 2019 was traced to a seafood wholesale market in Wuhan of China. Within a few weeks, a novel coronavirus tentatively named as 2019 novel coronavirus (2019-nCoV) was announced by the World Health Organization. We performed bioinformatics analysis on a virus genome from a patient with 2019-nCoV infection and compared it with other related coronavirus genomes. Overall, the genome of 2019-nCoV has 89% nucleotide identity with bat SARS-like-CoVZXC21 and 82% with that of human SARS-CoV. The phylogenetic trees of their orf1a/b, Spike, Envelope, Membrane and Nucleoprotein also clustered closely with those of the bat, civet and human SARS coronaviruses. However, the external subdomain of Spike’s receptor binding domain of 2019-nCoV shares only 40% amino acid identity with other SARS-related coronaviruses. Remarkably, its orf3b encodes a completely novel short protein. Furthermore, its new orf8 likely encodes a secreted protein with an alpha-helix, following with a beta-sheet(s) containing six strands. Learning from the roles of civet in SARS and camel in MERS, hunting for the animal source of 2019-nCoV and its more ancestral virus would be important for understanding the origin and evolution of this novel lineage B betacoronavirus. These findings provide the basis for starting further studies on the pathogenesis, and optimizing the design of diagnostic, antiviral and vaccination strategies for this emerging infection.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Predicting infectious SARS-CoV-2 from diagnostic samples

              Abstract Background RT-PCR has become the primary method to diagnose viral diseases, including SARS-CoV-2. RT-PCR detects RNA, not infectious virus, thus its ability to determine duration of infectivity of patients is limited. Infectivity is a critical determinant in informing public health guidelines/interventions. Our goal was to determine the relationship between E gene SARS-CoV-2 RT-PCR cycle threshold (Ct) values from respiratory samples, symptom onset to test (STT) and infectivity in cell culture. Methods In this retrospective cross-sectional study, we took SARS-CoV-2 RT-PCR confirmed positive samples and determined their ability to infect Vero cell lines. Results Ninety RT-PCR SARS-CoV-2 positive samples were incubated on Vero cells. Twenty-six samples (28.9%) demonstrated viral growth. Median TCID50/ml was 1780 (282-8511). There was no growth in samples with a Ct > 24 or STT > 8 days. Multivariate logistic regression using positive viral culture as a binary predictor variable, STT and Ct demonstrated an odds ratio for positive viral culture of 0.64 (95% CI 0.49-0.84, p 24. Conclusions SARS-CoV-2 Vero cell infectivity was only observed for RT-PCR Ct 24 and duration of symptoms >8 days may be low. This information can inform public health policy and guide clinical, infection control and occupational health decisions. Further studies of larger size are needed.
                Bookmark

                Author and article information

                Journal
                J Clin Virol
                J Clin Virol
                Journal of Clinical Virology
                Elsevier B.V.
                1386-6532
                1873-5967
                16 February 2021
                16 February 2021
                : 104764
                Affiliations
                [a ]Lamp Diagnostics, 348 Redwood Ave., Winnipeg, Manitoba, R2W 1S2, Canada
                [b ]Ormond Consulting, 863 Bannatyne Ave., Winnipeg, Manitoba, R3E 0W6, Canada
                [c ]Department of Medical Microbiology and Infectious Diseases, University of Manitoba, Room 507, Basic Medical Sciences Building, 745 Bannatyne Ave., Winnipeg, Manitoba, R3E 0J9, Canada
                Author notes
                [* ]Corresponding author.
                Article
                S1386-6532(21)00031-7 104764
                10.1016/j.jcv.2021.104764
                7885624
                33636553
                111d9192-3704-4b44-b03a-856faf8951be
                © 2021 Elsevier B.V. All rights reserved.

                Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.

                History
                : 27 November 2020
                : 10 February 2021
                : 14 February 2021
                Categories
                Article

                Microbiology & Virology
                rt-lamp, reverse transcription loop-mediated isothermal amplification,rt-pcr, reverse transcription polymerase chain reaction,ct, cycle threshold, rpa : recombinase polymerase amplification,sars-cov-2,point-of-care testing,isothermal amplification,rt-lamp,extraction-free,instrument-free