      Modified Thermocouple Sensor and External Reference Junction Enhance Accuracy in Indoor Air Temperature Measurements.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Indoor air temperature belongs to the most important climatic variables in indoor climate research, affecting thermal comfort, energy balance, and air movement in buildings. This paper focuses on measurement errors when using thermocouples in indoor temperature measurements, with special attention on measurements of air temperature. We briefly discuss errors in thermocouple measurements, noting that, for temperatures restricted to indoor temperature ranges, a thermocouple Type T performs much better than stated in "standards". When thermocouples are described in the literature, industrial applications are primarily considered, involving temperatures up to several hundred degrees and with moderate demands on accuracy. In indoor applications, the temperature difference between the measuring and the reference junction is often only a few degrees. Thus, the error contribution from the thermocouple itself is almost immeasurable, while the dominant error source is in the internal reference temperature compensation in the measuring instrument. It was shown that using an external reference junction can decrease the measurement error substantially (i.e., down to a few hundredths of a degree) in room temperature measurements. One example of how such a device may be assembled is provided. A special application of room temperature measurements involves measuring indoor air temperature. Here, errors, due to radiation influence on the sensor from surrounding surfaces, were surprisingly high. The means to estimate the radiative influence on typical thermocouples are presented, along with suggestions for modification of thermocouple sensors to lower the radiation impact and thereby improve the measurement accuracy.

          Related collections

          Author and article information

          Journal
          Sensors (Basel)
          Sensors (Basel, Switzerland)
          MDPI AG
          1424-8220
          1424-8220
          Oct 01 2021
          : 21
          : 19
          Affiliations
          [1 ] Department of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, SE-801 76 Gävle, Sweden.
          Article
          s21196577
          10.3390/s21196577
          8512746
          34640897
          12114774-72d5-4753-b1af-8f986ddc9e95
          History

          temperature sensor,thermocouple,radiation,induced errors,high accuracy,external cold-junction compensation,air temperature measurement

          Comments

          Comment on this article