      The six-minute walk test in healthy children: reliability and validity.

      The European Respiratory Journal
      Adolescent, Body Height, physiology, Child, Cohort Studies, Exercise, Exercise Test, methods, Female, Heart Rate, Humans, Male, Reproducibility of Results, Time Factors, Walking

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The aim of this study was to assess the reliability and validity of the 6-min walk test (6MWT) in healthy children. Chinese secondary school students were randomly recruited. They attended the current authors' unit on two occasions, separated by 2 weeks. Physical examination and standardised maximum incremental exercise testing on a treadmill were performed on the first visit. Spirometry and 6MWT were carried out on the second visit. A randomly selected subgroup was invited to return for repeat 6MWT at an interval of 2-4 weeks. Seventy-eight subjects were recruited; however, four failed to achieve maximal effort on exercise test. The final group included 43 young females and the mean+/-sd age of the subjects was 14.2+/-1.2 yrs. Physical examination was unremarkable in all cases. The mean+/-sd per cent predicted forced expiratory volume in one second was 91.4+/-10.2%. Concurrent validity was demonstrated by good correlation between the 6-min walking distance and maximum oxygen uptake determined on the exercise treadmill. Test-retest reliability was undertaken in 52 subjects, and the intraclass correlation coefficient (95% confidence interval) was calculated as 0.94 (0.89-0.96). In addition, Bland and Altman plots demonstrated a high degree of repeatability. In healthy children, the 6-min walk test is a reliable and valid functional test for assessing exercise tolerance and endurance.

          Related collections

          Author and article information

          Journal
          15929962
          10.1183/09031936.05.00134904
          so-override

          Chemistry
          Adolescent,Body Height,physiology,Child,Cohort Studies,Exercise,Exercise Test,methods,Female,Heart Rate,Humans,Male,Reproducibility of Results,Time Factors,Walking

          Comments

          Comment on this article