      Ultrasound-Guided Subclavian Vein Catheterization : A Systematic Review and Meta-Analysis

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Although ultrasound guidance for subclavian vein catheterization has been well described, evidence for its use has not been comprehensively appraised. Thus, we conducted a systematic review and meta-analysis to determine whether ultrasound guidance of subclavian vein catheterization reduces catheterization failures and adverse events compared to the traditional "blind" landmark method. All forms of ultrasound were included (dynamic 2D ultrasound, static 2D ultrasound, and Doppler).

          Related collections

          Most cited references19

          • Record: found
          • Abstract: found
          • Article: not found

          Ultrasonic locating devices for central venous cannulation: meta-analysis.

          To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation. 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature. Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. INTERVENTION REVIEWED: Guidance using real time two dimensional ultrasonography or Doppler needles and probes compared with the anatomical landmark method of cannulation. Risk of failed catheter placement (primary outcome), risk of complications from placement, risk of failure on first attempt at placement, number of attempts to successful catheterisation, and time (seconds) to successful catheterisation. 18 trials (1646 participants) were identified. Compared with the landmark method, real time two dimensional ultrasound guidance for cannulating the internal jugular vein in adults was associated with a significantly lower failure rate both overall (relative risk 0.14, 95% confidence interval 0.06 to 0.33) and on the first attempt (0.59, 0.39 to 0.88). Limited evidence favoured two dimensional ultrasound guidance for subclavian vein and femoral vein procedures in adults (0.14, 0.04 to 0.57 and 0.29, 0.07 to 1.21, respectively). Three studies in infants confirmed a higher success rate with two dimensional ultrasonography for internal jugular procedures (0.15, 0.03 to 0.64). Doppler guided cannulation of the internal jugular vein in adults was more successful than the landmark method (0.39, 0.17 to 0.92), but the landmark method was more successful for subclavian vein procedures (1.48, 1.03 to 2.14). No significant difference was found between these techniques for cannulation of the internal jugular vein in infants. An indirect comparison of relative risks suggested that two dimensional ultrasonography would be more successful than Doppler guidance for subclavian vein procedures in adults (0.09, 0.02 to 0.38). Evidence supports the use of two dimensional ultrasonography for central venous cannulation.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            International evidence-based recommendations on ultrasound-guided vascular access.

            To provide clinicians with an evidence-based overview of all topics related to ultrasound vascular access. An international evidence-based consensus provided definitions and recommendations. Medical literature on ultrasound vascular access was reviewed from January 1985 to October 2010. The GRADE and the GRADE-RAND methods were utilised to develop recommendations. The recommendations following the conference suggest the advantage of 2D vascular screening prior to cannulation and that real-time ultrasound needle guidance with an in-plane/long-axis technique optimises the probability of needle placement. Ultrasound guidance can be used not only for central venous cannulation but also in peripheral and arterial cannulation. Ultrasound can be used in order to check for immediate and life-threatening complications as well as the catheter's tip position. Educational courses and training are required to achieve competence and minimal skills when cannulation is performed with ultrasound guidance. A recommendation to create an ultrasound curriculum on vascular access is proposed. This technique allows the reduction of infectious and mechanical complications. These definitions and recommendations based on a critical evidence review and expert consensus are proposed to assist clinicians in ultrasound-guided vascular access and as a reference for future clinical research.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Practice advisory for preanesthesia evaluation: an updated report by the American Society of Anesthesiologists Task Force on Preanesthesia Evaluation.

                Bookmark

                Author and article information

                Journal
                Critical Care Medicine
                Critical Care Medicine
                Ovid Technologies (Wolters Kluwer Health)
                0090-3493
                2015
                July 2015
                : 43
                : 7
                : 1498-1507
                Article
                10.1097/CCM.0000000000000973
                25803646
                1a49a058-9eeb-4deb-8134-d0deb57fd0f8
                © 2015
                History

                Comments

                Comment on this article