16
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Whole-body biodistribution and radiation dosimetry of 18F-FP-(+)-DTBZ (18F-AV-133): a novel vesicular monoamine transporter 2 imaging agent.

      Journal of nuclear medicine : official publication, Society of Nuclear Medicine
      Drug-Related Side Effects and Adverse Reactions, Female, Fluorine Radioisotopes, Humans, Male, Middle Aged, Molecular Imaging, methods, Parkinson Disease, radionuclide imaging, Positron-Emission Tomography, Radiometry, Tetrabenazine, adverse effects, analogs & derivatives, diagnostic use, pharmacokinetics, Vesicular Monoamine Transport Proteins, metabolism

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Vesicular monoamine transporter 2 (VMAT2) is highly expressed in the endocrine cells and brain. We investigated the biodistribution and radiation dosimetry of (2R,3R,11bR)-9-(3-(18)F-fluoropropoxy)-3-isobutyl-10-methoxy-2,3,4,6,7,11b-hexahydro-1H-pyrido[2,1-a]isoquinolin-2-ol ((18)F-FP-(+)-dihydrotetrabenazine [DTBZ] or (18)F-AV-133), a potential VMAT2 imaging agent showing encouraging results in humans, to facilitate its future clinical use. Nine healthy human subjects (mean age +/- SD, 58.6 +/- 4.2 y) were enrolled for the whole-body PET scan. Serial images were acquired for 3 h immediately after a bolus injection of 390.7 +/- 22.9 MBq of (18)F-AV-133 per individual. The source organs were delineated on PET/CT images. The OLINDA/EXM application was used to determine the equivalent dose for individual organs. The radiotracer did not show any noticeable adverse effects for the 9 subjects examined. The radioactivity uptake in the brain was the highest at 7.5% +/- 0.6% injected dose at 10 min after injection. High absorbed doses were found in the pancreas, liver, and upper large intestine wall. The highest-dosed organ, which received 153.3 +/- 23.8 microGy/MBq, was the pancreas. The effective dose equivalent and effective dose for (18)F-AV-133 were 36.5 +/- 2.8 and 27.8 +/- 2.5 microSv/MBq, respectively. These values are comparable to those reported for any other (18)F-labeled radiopharmaceutical. (18)F-AV-133 is safe, with appropriate biodistribution and radiation dosimetry for imaging VMAT2 sites in humans.

          Related collections

          Author and article information

          Comments

          Comment on this article